2

When the air filter is to be 

removed, do not touch the metal 

parts of the unit.

It may cause an injury.

Do not clean unit when power is on 

as it  may c ause fi re an d el ectric sh ock,

it may cause an injury.

Operation with windows opened 

may cause wetting of indoor and 

soaking of household furniture.

When the unit is to be cleaned, 

switch off, and turn off the circuit 

breaker.

Use caution when unpacking and 

installing. Sharp edges could cause injury.

Do not clean the air conditioner 

with water.

Water may enter the unit and 

degrade the insulation. It may 

cause an electric shock.

This could injure the pet or plant.

It may cause electric shock and 

damage.

Do not put a pet or house plant 

where it will be exposed to direct 

air flow.

Ventilate the room well when

used together with a stove, etc.

An oxygen shortage may occur.

Do not use this air conditioner to 

preserve precision devices, food,

pets, plants, and art objects.It may 

cause deterioration of quality, etc. 

It may cause failure of product or 

fire.

Do not use for special purposes.

If water enters the unit, turn the unit off at the power 

outlet and switch off the circuit breaker. Isolate 

supply by taking the power-plug out and contact a 

qualified service technician.

!

!

!

!

It may cause failure of appliance 

or accident.

Appearance may be deteriorated 

due to change of product color or 

scratching of its surface.

If bracket is damaged, there is 

concern of damage due to falling 

of unit.

There is danger of fire or electric 

shock.

Operation without filters may cause 

failure.

It contains contaminants and 

could make you sick.

Stop operation and close the 

window in storm or hurricane.

!

Do not use strong detergent 

such as wax or thinner but use 

a soft cloth.

Ensure that the installation bracket of the 

outdoor appliance is not damaged due 

to prolonged exposure.

Hold the plug by the head of the 

power plug when taking it out.

!

Turn off the main power  

switch when not using the

unit for a long time.

!

! !

Always insert the filters securely. 

Clean filter once  every t wo w eeks.

!

Do not place heavy object on the power

cord and ensure that the cord is not 

compressed.

Do not drink water drained 

from air conditioner.

   This appliance is not intended for use by persons 

   (including children) with reduced physical ,sensory 

   or mental capabilities or lack of experience and 

   knowledge, unless t hey h aveb eengi ven su pervision

   or instruction concerning use of the appliance by 

   a person responsible for their safety. 

   Children should be supervised to ensure that they 

   do not play with the appliance. 

   If the supply cord is damaged, it must be replaced 

   by the manufacturer, its service agent or similarly 

   qualified persons in order to avoid a hazard.

CAUTION

2

CAUTION

Do not place obstacles around 

air-inlets or inside of air-outlet.

   The appliance shall be installed in accordance 

   with national wiring regulations.

   Do not operate your air conditioner in a wet room

 

 such as a bathroom or laundry room.

    Any appliance with electric heater shall have at

    l east 1 meter

 

s pace

 to combustible 

materials.

    

Contact

 an 

authorized service technician for

    

repair or maintenance of this unit.

   Contact 

an 

authorized installer for installation

    

of this unit.

IMPORTANT SAFETY INSTRUCTIONS

•  This appliance is not intended for use by 

persons (including children) with reduced 

physical ,sensory or mental capabilities or lack 

of experience and knowledge, unless they 

have been given supervision or instruction 

concerning use of the appliance by a person 

responsible for their safety.

•  Children should be supervised to ensure that 

they do not play with this appliance.

•  If the supply cord is damaged, it must be 

replaced by the manufacturer, its service agent 

or similarly qualified persons in order to avoid a 

hazard.

•  This appliance shall be installed in accordance 

with national wiring regulations

•  Do not operate your air conditioner in a wet 

room such as a bathroom or laundry room.

•  Any appliance with electric heater shall have at 

least 1 meter s pace to combustible materials.

•  Contact an authorized service technician for 

repair or maintenance of this unit.

•  Contact an authorized installer for installation of 

this unit.

Содержание RADS-101P

Страница 1: ...atures 12 14 Care and Cleaning 14 15 Troubleshooting Tips 15 16 Limited Express Warranty 17 Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CONTROL TABLE OF CONTENTS Installation Instructions 12 4 11 Normal Sounds Important Safety Instructions 1 3 Troubleshooting Tip 15 16 Air Con...

Страница 2: ...tric shock or fire due to excess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire...

Страница 3: ...g time Always insert the filters securely Clean filter once every two weeks Do not place heavy object on the power cord and ensure that the cord is not compressed Do not drink water drained from air conditioner This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they havebeengiven super...

Страница 4: ... the glass first If the window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner be careful to avoid cuts from...

Страница 5: ... and rear coils Save Carton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use NOTE Preliminary Instructions Do the following before starting to install unit See illustrations below Check dimensions of your unit to determine model type Unit Height 18 5 8 17 5 8 Unit Width Min Window Opening Min Window Width Max Window ...

Страница 6: ...tall the front panel see Fig 2 7 Remove shipping screws from top of unit and also on the side by the base if installed see Fig 5 8 Hold the cabinet while pulling on the base pan handle and carefully remove the unit 9 Add two foam inserts to holes in top of cabinet where shipping screws were removed see Fig 6 4 Push metal cabinet side to release plastic tabs on each side of front panel see Fig 3 5 ...

Страница 7: ...p and bottom legs of window filler panel frame into channel in the top angle and bottom rail Do both sides 4 Insert washer head locking 7 16 screws 2 into holes in top leg of filler panel frame see step 6 Do not totally tigh ten Allow leg to slide freely Screws will be tightened after section 6 4 Place Cabinet in 1 Open window and mark center of window stool as shown Fig 11 2 Place cabinet in wind...

Страница 8: ...tend Window Filler Panels 1 Carefully raise window to expose filler panel locking screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely Tighten locking screws on top Fig 17 3 Install support brackets with sill angle brackets attached to correct hole in bottom of cabinet as shown in Fig 16 4 Tighten all 6 bolts securely 1 2 Long Screws and Locknuts Loc...

Страница 9: ...et and Install Front to Unit 1 Lift air conditioner and carefully slide into cabinet leaving 6 inches protruding 2 DO NOT push on controls or finned coils 3 Be sure chassis is firmly seated towards rear of cabinet 4 Installation of front is the reverse of removal outlined in Section 1 INSTALL R1 HARDWARE only be applicable to Energy star models In order to minimize air leaks and ensure optimal ins...

Страница 10: ...ION INSTRUCTIONS Step 3 Slide the R1 insulation panel into the side curtain the side with pattern should facing the indoor side Fig 22 INSTALL WEATHER STRIPPING only be applicable to Energy star models 11 In order to minimize air leaks between the room air conditioner and the window opening trim the weather stripping with a proper length peel off the protective backing and plug any gaps if needed ...

Страница 11: ... The Wall Install tion are provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 does not support major structural loads such as the frame construction at ends of windows and under truss bearing points etc NOTE Consult local building codes prior to installation or a qualified carpenter 2 Prepare Wall 1 Prepare wall in frame construction including bric...

Страница 12: ...uction 5 Screw or nail cabinet wooden frame using shims if frame is oversized to eliminate distortion See Fig 8 Remember to maintain proper slope as described in Step 3 Fig 8 OPTIONAL Caulking and installation of trim on interior wall may be done You can buy wood from your local number or hardware supply On the outside caulk openings around top and sides of cabinet and all sides of wood sleeve to ...

Страница 13: ...perate on Fan Only section CLEAN AIR FEATURE on some models Press Clean Air button the ion generator is energized and will help to remove pollenand impurities from the air and trap them in the filter Electric Heating models Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan High Pitched Chatter High efficiency compressors may have a high pitc...

Страница 14: ...returns to the originally selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again Press Check filter button to initiate theis feature This feature is a reminder to clean the Air Filter for more efficient operation The LED light will illumi nat...

Страница 15: ...he compressor and possible circuit breaker tripping The fan will continue to run during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Left and Right Temp Timer buttons at the same time for 3 seconds Fresh Air Vent Control Fig A VENT CLOSED Fig B VENT OPEN Fig C VENT EXHAUST OPEN The Fresh Air ...

Страница 16: ...ime delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem Air from unit does not feel cold enough Set to a Lower temperature O O Room temperature below 62 F 17 C Cooling may not occur until room temperature O O rises above 62 F 17 C Thermostat set too cold for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a Higher setti...

Страница 17: ...y Noise when unit is cooling Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty air filter air restricted Clean air filter Air movement sound This is normal If too loud set to a slower FAN setting Outside temperature extremely hot Set FAN speed to a Highe...

Страница 18: ...of warranty period Without this proof the express warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective part If replacement parts are required within the period of this warranty Comfort Aire replacement parts shall be used any warranty on the replacement part s shall not af...

Страница 19: ...Owner s Manual RADS 101P RADS 121P RADS 123P 18 ...

Страница 20: ...RU YHULI LQJ GLPHQVLRQDO GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW DSSOLFDEOH UHJXODWLRQV LQ HIIHFW RQ GDWH RI PDQXIDFWXUH KRZHYHU FHUWLILFDWLRQV DUH QRW QHFHVVDULO JUDQWHG IRU WKH OLIH RI D SURGXFW 7KHUHIRUH LW LV WKH UHVSRQVLELOLW RI WKH DSSOLFDQW W...