COMFORT-AIRE RADS-101P Скачать руководство пользователя страница 14

Owner’s Manual  -  

RADS-101P, RADS-121P, RADS-123P

13

13

AIR CONDITIONER FEATURES

TO ADJUST FAN SPEEDS:

Press     to select the Fan Speed in four steps-Auto, 

Low, Med or High. Each time the button is pressed, 

the fan speed mode is shifted.For some models, the

fan speed can not be adjusted under HEAT mode. 

On Dry mode,the fan speed is controlled at Low 

automatically.

TO SELECT THE OPERATING MODE:

To choose operating mode, press      Mode button.Each 

time you press the button, a mode is selected in a 

sequence that goes from Auto, Cool, Dry ,heat(cooling

only models without)and Fan. The indicator light beside 

will be illuminated and remained on once the mode is 

selected.  

To operate on Auto feature:

In this mode, the fan speed cannot be adjusted, it starts 

automatically at a speed according to the room 

temperature. 

To operate on Fan Only:

Use this function only when cooling is not desired,such 

as for room air circulation or to exhaust stale air(on 

some models). (Remember to open the vent during this 

function, but keep it closed during cooling for maximum 

cooling efficiency.) You can choose any fan speed you 

prefer.

During this function, the display will show the actual

room temperature, not the set temperature as in the

cooling mode.

To operate on Dry mode:

In this mode, the air conditioner will generally operate 

in the form of a dehumidifier. Since the conditioned 

space is a closed or sealed area, some degree of 

cooling will continue.

When you set the air conditioner in AUTO mode, it will 

automatically select cooling, heating(cooling only models 

without), or fan only operation depending on what 

temperature you have selected and the room temperature.

The air conditioner will control room temperature 

automatically round the temperature point set by you.

In Fan only mode ,the temperature is not adjusted.

The unit will initiate automatically the Energy Saver 

function under Cool, Dry, Auto(only Auto-Cooling and 

Auto-Fan) modes.

SLEEP FEATURE:

Press      Sleep button to initiate the sleep mode. In 

this mode the selected temperature will increase

O

O

(cooling) or decrease (heating) by 2 F/1(or 2) C 30 

minutes after the mode is s elected. T he t emperature  

will then increase (cooling) or decrease  (heating) b y  

O

O

another 2 F/1(or 2) C after an additional 30  minutes.

T his n ew  t emperature w ill be m aintained f or 6  h ours

 before i t r eturns to  th e originally se lected tem perature.

This ends the Sleep mode and  the u nit w

  ill c ontinue

t o o perate  as originally programmed. The Sleep 

mode program can be cancelled at any time during 

operation by pressing the Sleep button again.

 Press      Check filter button to initiate theis feature.

 This feature is a reminder to clean the Air Filter for

 more efficient operation. The LED(light) will illumi-

 nate after 250 hours of operation. To reset after 

 cleaning the filter, press the Check Filter button and

 the light will go off.

CHECK FILTER FEATURE:

ENERGY SAVER FEATURE:

Press     Energy saver button to initiate this function.

This function is available on COOL, DRY, AUTO 

(only AUTO-COOLING and AUTO-FAN) modes.The 

fan will continue to run for 3 minutes after the 

compressor shuts off.The fan then cycles on for 2 

minutes at 10 minute intervals until the room 

temperature is above the set temperature, at which 

time the compressor turns back on and Cooling 

Starts.

FOLLOW ME FEATURE:

(on some models)

This feature can be activated from the remote 

control ONLY. The remote control serves as 

a remote thermostat allowing for the precise 

temperature control at its location.

To activate the Follow Me feature, point the remote 

control towards the unit and press the Follow Me 

button. The remote display is actual temperature at 

its location. The remote control will send this signal 

to the air conditioner every 3 minutes interval until 

press the Follow Me button again.If the unit does not 

receive the Follow Me signal during any 7 minutes 

interval, the unit will beep to indicate the Follow Me 

mode has ended. 

     When the unit is on or off, first press       Timer button, the 

     TIMER ON indicator light illuminates. It indicates the Auto 

     Start program is initiated. 

     When the time of TIMER ON is displayed ,press the Timer 

     button again, the TIMER OFF indicator light illuminates. 

     It indicates the Auto Stop program is initiated. 

     Press or hold the UP or DOWN button to change the Auto 

     time by 0.5 hour increments, up to 10 hours,then at 1 hour 

     increments up to 24 hours.The control will count down the 

     time remaining until start. 

     The selected time will register in 5 seconds, and the system 

     will automatically revert back to display the previous 

     temperature setting or room temperature when the unit is 

     on.(when the unit is off,there is no display.)

     Turning the unit ON or OFF at any time or adjusting the 

     timer setting to 0.0 will cancel the Auto Start/Stop timed 

     program.

 

TIMER: AUTO START/STOP FEATURE:

Light flashing

Follow

   Me

Содержание RADS-101P

Страница 1: ...atures 12 14 Care and Cleaning 14 15 Troubleshooting Tips 15 16 Limited Express Warranty 17 Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CONTROL TABLE OF CONTENTS Installation Instructions 12 4 11 Normal Sounds Important Safety Instructions 1 3 Troubleshooting Tip 15 16 Air Con...

Страница 2: ...tric shock or fire due to excess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire...

Страница 3: ...g time Always insert the filters securely Clean filter once every two weeks Do not place heavy object on the power cord and ensure that the cord is not compressed Do not drink water drained from air conditioner This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they havebeengiven super...

Страница 4: ... the glass first If the window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner be careful to avoid cuts from...

Страница 5: ... and rear coils Save Carton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use NOTE Preliminary Instructions Do the following before starting to install unit See illustrations below Check dimensions of your unit to determine model type Unit Height 18 5 8 17 5 8 Unit Width Min Window Opening Min Window Width Max Window ...

Страница 6: ...tall the front panel see Fig 2 7 Remove shipping screws from top of unit and also on the side by the base if installed see Fig 5 8 Hold the cabinet while pulling on the base pan handle and carefully remove the unit 9 Add two foam inserts to holes in top of cabinet where shipping screws were removed see Fig 6 4 Push metal cabinet side to release plastic tabs on each side of front panel see Fig 3 5 ...

Страница 7: ...p and bottom legs of window filler panel frame into channel in the top angle and bottom rail Do both sides 4 Insert washer head locking 7 16 screws 2 into holes in top leg of filler panel frame see step 6 Do not totally tigh ten Allow leg to slide freely Screws will be tightened after section 6 4 Place Cabinet in 1 Open window and mark center of window stool as shown Fig 11 2 Place cabinet in wind...

Страница 8: ...tend Window Filler Panels 1 Carefully raise window to expose filler panel locking screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely Tighten locking screws on top Fig 17 3 Install support brackets with sill angle brackets attached to correct hole in bottom of cabinet as shown in Fig 16 4 Tighten all 6 bolts securely 1 2 Long Screws and Locknuts Loc...

Страница 9: ...et and Install Front to Unit 1 Lift air conditioner and carefully slide into cabinet leaving 6 inches protruding 2 DO NOT push on controls or finned coils 3 Be sure chassis is firmly seated towards rear of cabinet 4 Installation of front is the reverse of removal outlined in Section 1 INSTALL R1 HARDWARE only be applicable to Energy star models In order to minimize air leaks and ensure optimal ins...

Страница 10: ...ION INSTRUCTIONS Step 3 Slide the R1 insulation panel into the side curtain the side with pattern should facing the indoor side Fig 22 INSTALL WEATHER STRIPPING only be applicable to Energy star models 11 In order to minimize air leaks between the room air conditioner and the window opening trim the weather stripping with a proper length peel off the protective backing and plug any gaps if needed ...

Страница 11: ... The Wall Install tion are provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 does not support major structural loads such as the frame construction at ends of windows and under truss bearing points etc NOTE Consult local building codes prior to installation or a qualified carpenter 2 Prepare Wall 1 Prepare wall in frame construction including bric...

Страница 12: ...uction 5 Screw or nail cabinet wooden frame using shims if frame is oversized to eliminate distortion See Fig 8 Remember to maintain proper slope as described in Step 3 Fig 8 OPTIONAL Caulking and installation of trim on interior wall may be done You can buy wood from your local number or hardware supply On the outside caulk openings around top and sides of cabinet and all sides of wood sleeve to ...

Страница 13: ...perate on Fan Only section CLEAN AIR FEATURE on some models Press Clean Air button the ion generator is energized and will help to remove pollenand impurities from the air and trap them in the filter Electric Heating models Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan High Pitched Chatter High efficiency compressors may have a high pitc...

Страница 14: ...returns to the originally selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again Press Check filter button to initiate theis feature This feature is a reminder to clean the Air Filter for more efficient operation The LED light will illumi nat...

Страница 15: ...he compressor and possible circuit breaker tripping The fan will continue to run during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Left and Right Temp Timer buttons at the same time for 3 seconds Fresh Air Vent Control Fig A VENT CLOSED Fig B VENT OPEN Fig C VENT EXHAUST OPEN The Fresh Air ...

Страница 16: ...ime delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem Air from unit does not feel cold enough Set to a Lower temperature O O Room temperature below 62 F 17 C Cooling may not occur until room temperature O O rises above 62 F 17 C Thermostat set too cold for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a Higher setti...

Страница 17: ...y Noise when unit is cooling Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty air filter air restricted Clean air filter Air movement sound This is normal If too loud set to a slower FAN setting Outside temperature extremely hot Set FAN speed to a Highe...

Страница 18: ...of warranty period Without this proof the express warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective part If replacement parts are required within the period of this warranty Comfort Aire replacement parts shall be used any warranty on the replacement part s shall not af...

Страница 19: ...Owner s Manual RADS 101P RADS 121P RADS 123P 18 ...

Страница 20: ...RU YHULI LQJ GLPHQVLRQDO GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW DSSOLFDEOH UHJXODWLRQV LQ HIIHFW RQ GDWH RI PDQXIDFWXUH KRZHYHU FHUWLILFDWLRQV DUH QRW QHFHVVDULO JUDQWHG IRU WKH OLIH RI D SURGXFW 7KHUHIRUH LW LV WKH UHVSRQVLELOLW RI WKH DSSOLFDQW W...

Отзывы: