COMFORT-AIRE PS-121B Скачать руководство пользователя страница 14

Installation, Operation & Maintenance Manual  -  

PS-121B / PSH-141A

13

13

PSH-141A

 

Installation, Operation & Maintenance

INSTALLATION  INSTRUCTIONS

Condensate drainage:

Remove the 

upper drain plug

Continuous 

drain hose

Fig.18a

Fig.18b

Fig.20

before using the unit.

Remove the 

lower drain plug

Continuous 

drain hose

drain hose

adaptor

drain hose

adaptor

- While operating in dry (dehumidify) mode, remove

 

the 

upper drain plug from the back of the unit, install

 

the 

drain connector (5/8 universal female mender) with

 

3 4  

hose(locally purchased). For the models
without drain connector, just attach the drain
hose to the hole. Place the open end of the
hose adaptor directly over the drain area in your

 

basement floor. Please refer to Fig.18a.

- While operating in heat pump mode, remove the

 

lower 

drain plug from the back of the unit, install the

 

drain 

connector (5/8 universal female mender) with
3/4  hose(locally purchased). For the models
without drain connector, just attach the drain
hose to the hole. Place the open end of the
hose adaptor directly over the drain area in your

 

basement floor. Please refer to Fig.18b.
NOTE: Make sure the hose is secure so there are
no leaks. Direct the hose toward the drain, making

 

sure 

that there are no kinks that will stop the water from

 

flowing. Place the end of the hose into the drain and

 

make sure the end of the hose is down to let the

 

water 

flow smoothly.(See Fig.18a,18b,19a). Do
not let it up.(See Fig.19b).

- When the water level of the bottom tray reaches

a predetermined level,

 

the unit beeps 8 times,

the digital display area shows "P1" . At this time
the air conditioning/dehumidification process will

 

immediately stop. However, the fan motor will

 

continue 

to operate(this is normal).
Carefully move the unit near a drain location,
remove the bottom drain plug and let the
water drain away (Fig.20).  Reinstall the bottom
drain plug and restart the machine until the "P1"

 

symbol 

disappears. If the error repeats, call for

 

service.

NOTE: Be sure to reinstall the bottom drain plug 

Fig.19a

Fig.19b

Heat Controller

Содержание PS-121B

Страница 1: ...ration Maintenance Manual Heat Controller 1900 Wellworth Ave Jackson MI 49203 517 787 2100 www heatcontroller com INSTALLATION OPERATION MAINTENANCE MANUAL Portable Room Air Conditioner and Heat Pump PS 121B PSH 141A French version of this manual is available on our website ...

Страница 2: ...Installation Operation Maintenance Manual PS 121B PSH 141A ...

Страница 3: ... Trouble shooting 15 AIR CONDITIONER FEATURES CARE AND MAINTENANCE TROUBLESHOOTING TIPS OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS IDENTIFICATION OF PARTS SAFETY PRECAUTIONS Safety rules 3 Operating condition and suggested tools 3 Electrical information 4 IDENTIFICATION OF PARTS Accessories 4 Identification of parts 5 AIR CONDITIONER FEATURES Electronic control operating instructions 6 OPERA...

Страница 4: ... touch the unit with wet or damp hands or to avoid electrical shock Do not remove any cover panels Never use this appliance if it is not working properly or if it has been dropped or damaged Never use the plug to start and stop the unit Always use the switch on the control panel Do not cover or obstruct the inlet or outlet grilles Do not use hazardous chemicals to clean or allow them to come into ...

Страница 5: ...ble substances vapors in the vicinity of this or any other appliance To avoid fire hazard or electric shock do not use an extension cord or an adaptor plug Do not remove any prong from the power cord WARNING Electrical Information IDENTIFICATION OF PARTS Accessories Check all the accessories are included in the package and please refer to the installation instructions for their usage PARTS PARTS N...

Страница 6: ... sides 3 1 2 3 4 6 7 8 9 10 11 Upper air intake 12 Fig 1 13 1 2 4 Fig 2 5 7 9 8 15 14 13 12 5 Upper air filter Behind the grille 6 10 11 Air outlet Drain outlet Power cord outlet Power cord buckle Bottom tray drain outlet Power plug socket Lower air filter Behind the grille 14 Lower air intake 15 Drain outlet Notes Items and are used to wrap up and store the power cord and plug when the unit is no...

Страница 7: ...mode is selected in a sequence that goes from AUTO COOL DRY FAN and HEAT The mode indicator light illuminates under the selected mode setting MODE select button Power switch on off POWER button 2 Used to adjust increase decrease O O temperature settings 2 F 1 C increments O O O O in a range of 62 F 17 C to 88 F 30 C or the TIMER setting in a range of 0 24hrs UP and DOWN buttons NOTE The control is...

Страница 8: ...erature The air conditioner will cool heat automatically around the temperature point set by you Under AUTO mode you can not change the fan speed When the unit is on press the Timer button to initiate the Auto off program the TIMER OFF indicator light illuminates Press the or buttons to select the desired time within 5 seconds Press the TIMER button again to initiate the Auto on timer program the ...

Страница 9: ... feature is unavailable under FAN or DRY mode If there is a loss of power once power is restored the unit will automatically restart in the last mode it was operating in prior to the power failure Auto Restart Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0 will cancel the Auto On Off timer program When an error malfunction E1 E2 E3 or E4 occurs the Auto On Off timed p...

Страница 10: ...ket Never place any obstacles around the air inlet or outlet of the unit Allow 1ft 3ft 30cm to 100cm of space from the wall for efficient air conditioning Fig 5 Window slider kit Installation Your window slider kit has been designed to fit most standard Vertical and horizontal window applications However it may be necessary for you to improvise modify some aspects of the installation procedures fo...

Страница 11: ... adjustable window kit if the width of window is less than 26 5 67 5 cm Open the window sash and place the window slider kit on the window stool Fig 9 3 Cut the foam seal adhesive type to the proper length and attach it on the top of the window Shown as in Fig 10 4 Close the window sash securely against the window 5 Cut the foam seal to an appropriate length and seal the open gap between the top w...

Страница 12: ...ow shorten the adjustable window kit if the width of window is less than 26 5 67 5 cm Open the window sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the proper length and attach it on the top of the window Shown as in Fig 14 4 Close the sliding sash securely against the window 5 Cut the foam seal to an appropriate length and seal the open g...

Страница 13: ...us pages for window kit installation 2 Insert the hook of the Exhaust hose into the hole seat of the air outlet and slide down the Exhaust hose along the arrow direction See Fig 17 for installation IMPORTANT DO NOT OVER EXTEND OR BEND THE EXHAUST HOSE Fig 17 Fig 16 COOL HEAT or AUTO mode FAN OR DEHUMIDIIFY or mode Install Remove CAUTION Make sure that there are no obstacles around the air outlet o...

Страница 14: ... models without drain connector just attach the drain hose to the hole Place the open end of the hose adaptor directly over the drain area in your basement floor Please refer to Fig 18b NOTE Make sure the hose is secure so there are no leaks Direct the hose toward the drain making sure that there are no kinks that will stop the water from flowing Place the end of the hose into the drain and make s...

Страница 15: ... mode for half a day in a warm room to dry the appliance inside and prevent mold from forming Stop the appliance and unplug it wrap the cord and bundle it with the buckle and plug the power plug into the socket on the back of the unit Fig 23 Remove the batteries from the remote controller Clean the air filter and reinstall it Unscrew the exhaust hose from the unit and pull out when uninstallating ...

Страница 16: ...mperature is lower than the set temperature Cooling mode The windows or doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocked by dust 2 Not cool enough Place the unit on a flat level ground if possible This is normal operation The ground is not level or not flat enough The sound com...

Страница 17: ...Installation Operation Maintenance Manual PS 121B PSH 141A 16 ...

Страница 18: ... GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW DSSOLFDEOH UHJXODWLRQV LQ HIIHFW RQ GDWH RI PDQXIDFWXUH KRZHYHU FHUWLILFDWLRQV DUH QRW QHFHVVDULO JUDQWHG IRU WKH OLIH RI D SURGXFW 7KHUHIRUH LW LV WKH UHVSRQVLELOLW RI WKH DSSOLFDQW WR GHWHUPLQH ZKHWKHU D VS...