5
OPERATION
Power Control
The Power Control turns the unit on and off.
Set Temperature/Timer Display
Shows the set temperature when the unit is in operation and hours when the timer is
being set.
THE TEMPERATURE DISPLAY ONLY SHOWS THE SET TEMPERATURE, NOT
THE ACTUAL ROOM TEMPERATURE.
Temperature/Timer Hour Controls
These buttons are used to raise or lower the set temperature in increments of 1° from
66°F to 88°F. By depressing both buttons at once, the display will toggle between
Celsius and Fahrenheit. When the timer is being set, these buttons are used to change
the hour setting in increments of 1 from 00 to 24.
Mode Control
A green light will indicate which mode is currently
being utilized.
Cool Mode –
The unit will circulate and cool the air.
Heat Mode (Heat Models Only)–
The unit will circulate and heat the air.
Heater Safety Feature- When heater is powered off, low fan will automatically stay on
and run for 60 seconds to ensure the removal of residual heat, meanwhile, the Low Fan
LED blinks until the low fan stops.
Fan Mode –
The unit will only circulate the air.
Energy Saver Mode –
(The energy saver mode is designed to operate with Cool mode only)
The fan will switch from the set fan speed to LO whenever the compressor turns off in
response to the thermostat. When the compressor cycles back on, the unit will return to
the original fan setting.
Fan Speed Control
High, Medium*, Low and Auto
The settings are adjusted with the Fan Speed Control, each time the button is depressed
it changes the setting. A green light will indicate which setting is currently being used.
When the AUTO feature is selected while the air conditioner is in the COOL or HEAT
mode, the fan speeds will change automatically as the temperature in the room
changes.
COOL Mode
• 7° or more above the set temperature
will use HI FAN.
• 4° or less above the set temperature
will use LO FAN.
HEAT Mode (Heat models only)
• 9° or more below the set temperature
will use HI FAN.
• 4° or less below the set temperature
will use LO FAN.
*MEDIUM FAN NOT available on HEAT models.
Set Temperature/Timer
Display
Temperature/Timer
Hour Controls
Timer Control
Fan Speed Control
Mode
Control
Power
Control
A
A.
D.
B.
E.
C.
F.
B
C
D
E
F
Built-in three minute timing delay.
If this electronic unit will not respond to touch pad or
remote control commands, it is necessary to unplug the
unit from the electrical outlet for five seconds and then
plug the unit back in.
Auto restart feature:
In the event of a power failure, this feature allows
the unit to resume operation once power has
been restored, retaining the most recent settings.
Upon restoration of power, the timer mode may
need to be reset if being utilized.
CAUTION
Heat/Cool models or units with electric
heat are designed to be used only as a
supplemental heat source. They should be
used in addition to regular heating
systems and never as the primary source
of heat.
Содержание Comfort Air
Страница 23: ......