508115-01
Issue 2043
Page 2 of 5
4
Technical Speci ications -
GDD95C
MODEL NUMBER GUIDE
REV CODE
REVISION
NOM. CFM X 100
2 TON ADD ON COOLING
3 TON ADD ON COOLING
4 TON ADD ON COOLING
5 TON ADD ON COOLING
CABINET WIDTH
A = 14.5” WIDTH
B = 17.5” WIDTH
C = 21.0” WIDTH
D = 24.5” WIDTH
BTUH INPUT
HEATING INPUT X 1000
GAS
G = GAS FURNACE
CONFIGURATION
DD = DOWNFLOW
AFUE
80 = 80% EFFICENCY
92 = 92% EFFICENCY
95 = 95% EFFICENCY
G DD 95 C
G DD 95 C 00 44 55 BB 3 M
3 M
STAGES/MOTOR
A = SINGLE STAGE PSC
C = SINGLE STAGE CONSTANT TORQUE
T = TWO STAGE VARIABLE SPEED ECM
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
%
Nom.
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
DOWNFL
OW
GDD95C045B3M
44,000
42,000
95.0%
1-1/2 — 3
1/2
120 - 60 - 1
15
6.8
40
131
GDD95C070B4M
66,000
64,000
95.0%
2-1/2 — 4
1/2
120 - 60 - 1
15
8.4
40
144
GDD95C090C4M
88,000
85,000
95.0%
2-1/2 — 4
1/2
120 - 60 - 1
15
8.4
40
160
GDD95C110C5M
110,000
106,000
95.0%
3 — 5
1/2
120 - 60 - 1
15
10.9
40
174