background image

IOM - SLEEVED PLUG VALVES, UNIFLOW PP

©COMEV

AL

 V

AL

VE SYSTEMS 

Technical Dept. Ref. IOM - SLEEVED PLUG V

AL

VES, UNIFLOW PP

 - Ed.16/05

Comeval V

alve Systems reserves the right to alter any technical data contained in this Manual without prior notice. Regularly updated data on www

.comeval.es

8. – TROUBLESHOOTING

In the event of malfunction or faulty operating performance, check that the installation and adjustment work has been 

carried out and completed in accordance with this Manual.

9. – TROUBLESHOOTING TABLE

Technical support always available through our website www.comeval.es or your local distributor.

10. – DISMANTLING THE VALVE

 

   

ATTENTION!

- Read chapters 10 & 11 before carrying out installation and repair work!

- Read chapter 6 before recommissioning!

Page 6

FAULT

POSSIBLE CAUSE

CORRECTING MEASURES

No flow

Not enough flow

Flange covers or protection not removed

Clear valve entrances

Valve closed or almost closed

Check valve position

Pipe system clogged

Check piping system

Broken flange

Bolts not properly tightened

Re-align piping and fit new valve

Mating flanges not properly aligned

Leakage between body/

cover

Bolts loose or gasket damaged

Retighten bolts or change gasket

Parts not well aligned

Check alignment

Metal Sealing surfaces damaged

Repair or change damaged surfaces

Leakage through the stem Normal wear after cycles or long time without 

use

Retighten bolts

Packing or stem worn out or damaged

Replace parts

Metal Sealing surfaces damaged

Repair or change damaged surfaces

Valve not tight at closing

Valve is not in closed position

Check correct handle rotation

Dirt trapped between plug and sleeve

Open to sweep dirty and close back

Install a strainer upstream

Seats damaged

Machine plug or change seating parts 

(sleeve and plug)

Plug surface damaged

Repair or change plug

Too much pressure

Check the system

Too high operating torque, 

lever hard to turn

Packing too tight

Check packing gland tightening

Packing rings damaged or with dirt

Inspect and replace/clean parts

Stem is bended

Replace stem

Sleeve damaged

Repair or change sleeve

Too much pressure

Check the system

 

   

ATTENTION!

The following points must be observed:

- Pressureless pipe system

- Medium must be cool

- Plant must be drained

- Purge pipe systems in case of toxic, corrosive, flammable or caustic media

 

   

ATTENTION!  

- It is essential that the safety regulations are observed when identifying faults.

Содержание UNIFLOW PP Series

Страница 1: ...RS 2 2 1 Significance of symbols 2 2 2 Explanatory notes on safety information 2 3 0 PRESERVATION STORAGE AND TRANSPORT 2 4 0 DESCRIPTION 2 4 1 General Description 2 4 2 Area of Application 2 4 3 Oper...

Страница 2: ...in Data Sheets and product marking must also be observed and complied with to the fullest extent in order to avoid faults which in turn can cause serious injury to persons or damage to property 3 PRE...

Страница 3: ...ion Check correct position of nameplate and handle with care to avoid personnel cuttings When the valve is operated there is a crushing hazard between the plug and the sleeve Ensure the valve is not u...

Страница 4: ...rings experiment a relaxation and some retighten of the gland could be needed during start up Over tightening will increase operating torque and will reduce life of the packing Also after several ope...

Страница 5: ...he valve The plug should be lifted straight up from the body followed by inspection for any scoring or process damage such as erosion or cavitation If the plug uses O rings or sleeves as the primary s...

Страница 6: ...age between body cover Bolts loose or gasket damaged Retighten bolts or change gasket Parts not well aligned Check alignment Metal Sealing surfaces damaged Repair or change damaged surfaces Leakage th...

Страница 7: ...wn by specifications or other agreements Justified complaints will be eliminated by repair carried out by us or by a specialist appointed by us No claims will be accepted beyond the scope of this warr...

Страница 8: ...Ed 16 05 Comeval Valve Systems reserves the right to alter any technical data contained in this Manual without prior notice Regularly updated data on www comeval es 12 PARTS LIST N PART 01 Body 02 Sle...

Отзывы: