18
• external detergent suction hose kit
[ETM 100, ETM 130, ETM 150]
;
• instruction manual - safety precautions;
• instruction manual - operation and maintenance;
• warranty certificate;
• after-sales centre booklet;
• EC declaration of conformity;
• nozzle cleaning pin.
In case of problems, contact your dealer or an authorised after-sales centre.
OPTIONAL ACCESSORIES
The standard fittings of the high-pressure cleaner can be integrated with the following range of accessories:
•
BA
type water mains disconnector: mandatory for connecting up to the drinking water mains.
• sandblasting lance: designed to clean surfaces, eliminating rust, paint, scale, etc.;
• drain cleaning kit: designed to unblock pipes and ducts;
• rotating-nozzle lance: designed to remove resistant dirt;
• foam lance: designed for more effective detergent distribution;
• lances and nozzles of various types.
INSTALLATION - FITTING ACCESSORIES
• Connect the quick coupling (15) of the hose (14) to the water outlet connection (7), screw down and secure.
Operation E in fig. 6.
• Screw up the connection (13) of the high-pressure hose to the thread of the spray gun (9) and tighten well
using two 22 mm fixed wrenches (not supplied)
[ETM 71
- 19 mm]. Operation D in fig. 6.
• Fit the filter (21) in the water inlet connection (20). Fit the seal (22) in the water inlet quick-fit connection (23)
and screw up to the connection (20). Operation A in fig. 2.
OPERATION - PRELIMINARY ACTIVITIES
• Move the high-pressure cleaner to work position.
• Completely unwind the high-pressure hose (14).
• Attach a supply pipe to the water inlet’s quick connection (23) using a normal garden connector. Operation F
in fig. 6.
• Open the water supply tap and make sure this is not dripping;
- if the connection is made to the drinking water mains, a
BA
type water mains disconnector (26) must be
used, in conformity with EN 12729 standard, and available from your dealer (fig. 5). With regard to its use,
refer to the relative instruction manual;
- in case of supply from a water tank, introduce the suction hose inside the tank and make sure the vertical
distance between the water level and the pump is no more than 1.5 m (4.9 ft). Operation G in fig. 5.
• Make sure the master switch (1) is on “0” position and insert the plug. Operation C in fig. 6.
• Move the master switch (1) to position “1”.
• Press the spray gun lever (19) and wait for a continuous jet of water to come out;
-
ETM 130
: in case of supply from a water tank, load the pump by pressing the “Priming” button (27) fig. 5;
release this when a continuous jet of water starts to come out of the spray gun.
• Move the master switch (1) to “0” position and connect the lance hose (10) to the spray gun (9), tightening
well. operation B in fig. 6.
STANDARD OPERATION (HIGH PRESSURE)
• Make sure the nozzle holder head (11) is not in the detergent dispensing position
[ETM 100, ETM 130,
ETM 150]
(refer to “
OPERATION WITH DETERGENT
” paragraph).
• Start the high-pressure cleaner again moving the master switch (1) to position “1”.
• Press the gun spray lever (19), making sure the spray of the nozzle is even and this is not dripping.
• If necessary, adjust the pressure by turning the knob (6). Turn clockwise to increase pressure, anticlockwise
to decrease it.
Содержание ETM 100
Страница 2: ...ETM 71 ETM 130 ETM 100 ETM 150...
Страница 3: ...ETM 130 ETM 71 ETM 130 1 3 1 4 2 6 7 8 5 5...
Страница 4: ...2 9 10 11 12 13 15 14 18 19 S 23 22 21 20 A...
Страница 5: ...ETM 100 ETM 130 ETM 150 3 11 16 17 A B 24 17 25 17...
Страница 6: ...ETM 71 4 29 L 30 28...
Страница 7: ...ETM 130 5 1 5 m 4 9 ft G 26 27...
Страница 8: ...6 D B F E C...
Страница 60: ...60 19 1 0 14 19 14 4 21 23 21 12 14 16 ETM 100 ETM 130 ETM 150 ETM 71 ETM 130 ETM 150 5 1...
Страница 61: ...61 RU 200 500 1 1 21 5 G 6 ETM 100 ETM 130 ETM 150 11 3 A 3 B 5 G BA...
Страница 62: ...62 ETM 100 ETM 130 ETM 150 11 3 B 3 A ETM 100 ETM 130 ETM 150 16 ETM 100 ETM 130 ETM 150 BA 5 G 1...
Страница 63: ......