TROUBLESHOOTING TABL
TROUBLES
CAUSES
SOLUTIONS
1 THE GENERATOR PRESSU-
RE DOES NOT INCREASE
- Resistance contactor
- Pressure switch
- Resistance
- Thermal resistance
- PT100 Thermal resistance
- Check the resistance contactor
- Check the pressure switch
- Check the resistance
- Check that the temperature is at
least 133°C
- Check
2 THE PUMP CANNOT RUN
2.1 It loads no water
2.2 Sound allarm
2.3 It does not run
- The water tank is empty
- Pump
- Check the electronic level
- Lack of water in the tank
- water solenoid valve
- Pump
- Water level probe
- Fill the tank
- Replace the pump
- Replace the solenoid valve
- Fill the tank
- Replace the pump
- Check and eventually replace it
- Clean the probe
3 THE SAFETY VALVE OPENS
REPEATEDLY
3.1 It keeps on
loading water
- Boiler water level probe
- Check the electronic level
- Pressure switch
- Resistance contactor
- Safety valve
- Clean the probe
- Replace it
- Replace the pressure switch
and check that the connection
copper tube is free from
incrustations.
- Replace the resistance contactor
- Replace the safety valve
EN
27
Содержание 9204 0006
Страница 2: ...2...
Страница 16: ...16...
Страница 28: ...EN 28...
Страница 76: ...SL 76...
Страница 78: ...OFF 09c 60 16c 17c 17c IEC OFF L RU 78...
Страница 79: ...60364 1 30 A 30 04i 23i 21i 08i 22i 10 180 RU 79...
Страница 80: ...10 35 RU 80...
Страница 81: ...2 ON OFF elettriciy BOILER START GUN START k 1000 400 RU 81...
Страница 83: ...2 ON OFF H2O IL R START GUN START GUNSTART OFF RU 83...
Страница 85: ...OFF A 1 2 RU 85...
Страница 86: ...3 4 5 6 7 8 9 2012 19 EU 2012 19 EU RU 86...
Страница 87: ...RU 87...
Страница 88: ...1 PT100 t 133 C 2 2 1 2 2 2 3 3 3 1 RU 88...