 The sensors (under the probe cover) should not be exposed to direct contact with 
water or other liquids. Probe should not be exposed to mechanical vibrations. 

Storing conditions: temperature -10 to +60 °C relative humidity 5 to 95 %RH 
Dimensions: 141 x 71 x 27 mm 
Weight including battery: approximately 150 g 
Material of the case: ABS 
Material of the probe: duralumin with the black eloxal surface finish 

  

Battery life depends  on selected display refresh  mode (see below). In FAST  mode display is 

refreshed in shortest possible interval with highest current consumption. In dynamic mode display 
is  refreshed  in  interval  up  to  5  s  in  case  measured  values  remain  stable.  Refresh  interval  is 
shortened  to  approximately 0.7  s  only  if  measured  values  change.  Current  consumption  in  this 
mode  in  usual  operation  is  lower,  battery  life  is  up  to  4  times  longer.  The  FAST  mode  is 
recommend to use only in cases, when slower display response is not acceptable. 

Battery voltage drop below 7 V is indicated with blinking of "BAT" in default display mode 

(displaying of actual values) and FAST mode is automatically canceled to save the battery. At the 
same time audio indication of alarms is automatically switched OFF. 

If  instrument  is  powered  from  external  ac/dc  adapter,  internal  9V  battery  is  replaced  with 

rechargeable NiCd accumulator. In usual operation from adapter accumulator is charged only with 
small  current.  If  accumulator  is  totally  discharged,  its  full  charging  in  instrument  takes 
approximately  100  hours.  Instrument  with  accumulator  is  not  recommended  for  permanent 
operation without ac/dc adapter plugged. Accumulator works only as  a standby source in case of 
power mains failure. 

 
 

Switching ON and OFF the instrument 

 

 

Connect  the  external  probe  to  the  connector  before  switching  ON  the 
instrument.  Probe  is  calibrated  with  the  delivered  instrument  and  it  is  not 
possible to replace it with another (if you have several instruments of this 
type). Switch ON the instrument by pressing ON/OFF key. After switching 
ON  the  instrument  all  symbols  on  the LCD are displayed.  If the ON/OFF 
key  is  being  held  pressed,  all  LCD  symbols  are  displayed  till  the  key  is 
released. 

In usual operation instrument then starts the measurement mode and actual measured values are 

displayed.  If  instrument  is  ON,  do  not  disconnect  or  connect  the  probe  to  prevent  storing  of 
incorrect value to minimum and  maximum memory. 

 
 

 

Displaying of actual measured values 

 

In  this  mode  is  instrument  anytime  after  switching  ON.  It  is  possible  to  enter this  mode from 

other  modes  by  pressing  or  by  repeating  pressing  of  MENU  key.  If  the  external  probe  is  not 
connected properly or probe temperature is out of measuring range, reading -- is displayed on the 
appropriate LCD line. 
 

Temperature  in  °C  is  displayed  on  the  upper  LCD  line  and  relative 
humidity in %RH is displayed on the lower LCD line. 
 

 
 

Содержание COMMETER C3121P

Страница 1: ...COMMETER C3121P Digital thermometer hygrometer with external probe for compressed measurement Instruction manual...

Страница 2: ...element of the device is an external probe see picture designed for compressed air measurement up to 25 bars The probe has a cable length of 1 to 4 meters with connector Mechanical connection of the...

Страница 3: ...ge current consumption 0 15 to 0 7 mA depending on operation mode Protection device IP20 sensors are located in cover with IP40 protection Typical life of Zinc Chloride battery 4 months Typical life o...

Страница 4: ...ator In usual operation from adapter accumulator is charged only with small current If accumulator is totally discharged its full charging in instrument takes approximately 100 hours Instrument with a...

Страница 5: ...ault mode Minimum and maximum memory is cleared from menu after confirmation selection CLR see below Values in HOLD MIN and MAX memories remain stored even after instrument is switched OFF Functions a...

Страница 6: ...ication can be activated if menu AUDI On is selected see setting described above Alarm activation of each value can be disabled by setting lower alarm limit of the desired value up to its maximum This...

Страница 7: ...ions and data in memory HOLD MIN and MAX will be lost For the same reason do not disconnect the battery for longer than 1 minute even if instrument is switched OFF If it happens or if battery is total...

Страница 8: ...rupting the main line closing valve 5 the sample flow is regulated by this valve Measurement accuracy is typically not affected by the sample flow rate but at low speeds increasing response time outle...

Отзывы: