Legend: buttons and indicator LEDs

 

f

Press the desired button once to activate the associated function

Wait for approximately 1 sec. before pressing the same button again. Pressing the same button several times in 

quick succession will cancel the command.

Description of buttons 

LOCK-RELEASE

 

f

Press the key to activate the 

corresponding door lock

ACTUATOR 

(default*)

 

f

Press the key to activate the corresponding 

relay

SELF-ACTIVATION 

(default*)

 

f

Press the key to access real-time viewing 

of the camera for the outdoor entrance 

panel

SILENT MODE (Privacy)

 

f

Press the key to enable silencing of the 

ringtone on receipt of a call from the 

outdoor entrance panel and from the 

switchboard

PROGRAMMABLE BUTTONS

Applies to Art. 6701W/8

Indicator LED description

Flashing LED: incoming call
1 flash after pressing button: confirms door 

opening
Slow flashing: door open
Flashing LED: device in programming mode
4 flashes: system busy
Steady LED: Silent mode (Privacy) enabled
3 flashes every 5 sec.: 

 Door Opening Upon Call 

(Doctor) function enabled

(*) Buttons may be programmed as:

• 

AUTOMATIC LOCK-RELEASE ON RECEIPT OF CALL (Doctor)

See paragraph 

“Pressing and holding keys (disabled by default from firmware version 3.0.1 (3.2.0 for 6701W/8)”

• 

INTERCOM

Allows a call from one internal unit to one or more internal units

• 

CALL TO A MAIN OR SECONDARY SWITCHBOARD

• 

PRIORITY CALL TO SWITCHBOARD (“PAN”)

• 

CALL TO CARETAKER DOOR-ENTRY PHONE

Pressing and holding keys 

(disabled by default from firmware version 3.0.1 (3.2.0 for 6701W/8)

Pressing and holding keys adds further functions to the door entry monitor.

Carry out the procedure described below to enable - or disable, depending on the factory setting - the press and 

hold feature:

 

Door entry monitor in standby.

1. 

Take note of the S2 DIP-switch settings.

2. 

Enter programming mode by setting S2 DIP-switches 1, 3, 5 to ON.

 

» the LED   flashes

3. 

Press   to enable (or press   to disable).

4. 

Make sure the 

 key flashes 4 times and the confirmation tone is emitted.

5. 

Restore the initial configuration of the S2 DIP-switches.

 

» LED   switches off

Once the procedure is complete, you will be able to enable the following functions:

Automatic lock-release on receipt of call (Doctor mode)

Automatic activation of the Lock-release relay on receipt of a call originating from the external unit.

 

f

Press and hold (4 sec.) the programmed button to enable/disable the function.

Self Activation

 

f

Press and hold (4 sec.) the programmed button to disable the function. (Enabled by default).

Содержание Mini 6701W

Страница 1: ...EN TECHNICAL MANUAL Passion Technology Design Mini door entry monitor with handset Art 6701W 6701W BM 6701W 8...

Страница 2: ...ings Installation All activities connected to the installation of Comelit products must be carried out by qualified technical personnel with careful observation of the indications provided in the Manu...

Страница 3: ...closure In systems with more than one door entry monitor connected in cascade only the door entry monitor furthest away must have CV5 closed 11 Pin for securing terminal block Terminal block for syste...

Страница 4: ...sing and holding keys disabled by default from firmware version 3 0 1 3 2 0 for 6701W 8 INTERCOM Allows a call from one internal unit to one or more internal units CALL TO A MAIN OR SECONDARY SWITCHBO...

Страница 5: ...Ringtone volume Yes Yes Yes Screen brightness Yes Yes Yes Screen colour Yes Yes Yes MAIN FUNCTIONS Lock release Yes Yes Yes Actuator control Yes Default key 1 Yes Default key 1 Yes Default key 1 Self...

Страница 6: ...6 Installation optional fixing 16 0 cm 17 5 cm 1C 1B 1A 4 3 2 2 1 6 7 1 3 2 CLACK CLACK CLACK 5...

Страница 7: ...C L L P F C FLOOR DOOR CALL LM LM OUT L IN L IN L OUT L 20 m MAX Use shielded cable for the connection and do not route the cables in the vicinity of heavy inductive loads or power supply cables 230V...

Страница 8: ...209 1210 or 1210A you can configure a maximum of 1 main door entry monitor while in systems with power supply unit 4888C you can configure up to 2 main door entry monitors To configure the door entry...

Страница 9: ...Actuator AI Self Activation CCP Call to main switchboard CCS Call to secondary switchboard K Caretaker door entry phone call PAN Priority call to switchboard INT Intercom call general programmable or...

Страница 10: ...DIP switches according to the call address of the desired apartment See Addressing table 5 Press and release the button to be associated with the function Correct procedure indication the LED flashes...

Страница 11: ...note of the S1 S2 settings and restore them when programming is complete Set the DIP switches as shown in the figure S1 S2 x4 x10 OK prog KO prog x4 x10 OK prog KO prog Generic actuator coded actuato...

Страница 12: ...ction Correct procedure indication the LED flashes for a few seconds and a confirmation tone sounds 6 Exit programming mode by setting S2 DIP switch 6 to OFF LED switches off S2 7 Set S2 DIP switches...

Страница 13: ...confirmation tones sound to change the floor door call ringtone Any further pressing of the button repeats the sequence described above 3 Press and release to scroll through the available ringtones in...

Страница 14: ...46 2 3 4 6 76 3 4 7 106 2 4 6 7 136 4 8 166 2 3 6 8 196 3 7 8 226 2 6 7 8 17 1 5 47 1 2 3 4 6 77 1 3 4 7 107 1 2 4 6 7 137 1 4 8 167 1 2 3 6 8 197 1 3 7 8 227 1 2 6 7 8 18 2 5 48 5 6 78 2 3 4 7 108 3...

Страница 15: ...2nd edition 03 2021 code 2G40002676 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Отзывы: