Connections

  20 m MAX - 

Connect a single call repetition device for each user code. 

  20 m MAX

 - Use shielded cable for the connection and do not route the cables in the vicinity of heavy inductive loads 

or power supply cables (230 V/400 V). 

Where multiple door-entry phones or door entry monitors have the same user code, connect the CFP button on one 

only; all the devices will ring simultaneously.

  For programming procedure details, see paragraph: 

“LED/alarm/lock-release/actuator programming" on page 

15

.

12/24V

AC/DC

1122/A

(12V)

IN

2 1

IN

2

+

-

1

P

F

C

L

L

P

F

C

-

S

+

S

C N

O

N

C

-

+

  20 m MAX - 

Connect a single call repetition device for each user code. If inductive loads are connected, the connection 

of 470nF capacitance in parallel with the C-NO contacts of Art. 1122/A is recommended

Variant: connection of call repetition device art. 1122/A

1212/B

0

2

0

0

3

2

0

ALIMENTAZIONE

SUPPLEMENTARE

(SE NECESSARIA)

6601W

1214/2C

MONTANTE 

VIDEOCITOFONICA

MONTANTE 

VIDEOCITOFONICA

IN

2 1

IN

2

+

-

1

P

F

C

L

L

P

F

C

-

S

+

S

CHIAMATA 

FUORIPORTA

SUONERIA

SUPPLEMENTARE

1229

CV1

CV2

LM

LM

OUT

L

IN

L

IN

L

OUT

L

INGRESSO 

PROGRAMMABILE

CV6

A
B

ADDITIONAL

POWER SUPPLY

(IF REQUIRED)

ADDITIONAL

RINGTONE

FLOOR DOOR 

CALL

PROGRAMMABLE 

INPUT

VIDEO ENTRY 

RISER

VIDEO ENTRY 

RISER

Содержание Icona Manager

Страница 1: ...Icona 2 wire door entry monitor Art 6601W Art 6601W BM Passion Technology Design EN TECHNICAL MANUAL...

Страница 2: ...communication systems in residential commercial industrial and public buildings Installation All activities connected to the installation of Comelit products must be carried out by qualified technica...

Страница 3: ...5 6 access to programming DIP 7 for power supply voltage management Paragraph Power supply management on page 9 DIP 8 for setting main and secondary door entry monitor Paragraph Main and secondary do...

Страница 4: ...he function associated with it 1 2 Press and hold keys Disabled by default from firmware version 1 5 0 Pressing and holding keys adds further functions to the door entry monitor Carry out the procedur...

Страница 5: ...s Loudspeaker 40 x 20 H mm 8 Ohm 2W 40 x 20 H mm 8 Ohm 2W Technologies implemented Full Duplex Full Duplex ELECTRICAL SPECIFICATIONS Type of power supply Power supply via video entry bus Power supply...

Страница 6: ...6 Installation Installed in flush mounted box art 6117 3 160 cm 130 cm 2 14 2 cm 14 7 cm 1 2 1 6 Lmax 10 cm Lmin 6 cm 5 2 3 4 5 1 4 1 1 2 CLACK 2 9 2 1 8 2 1 7 1 2 DISASSEMBLY...

Страница 7: ...ting in 503 series box round box 2 1 7 2 1 6 1 2 3C 2 1 3B Lmax 7 cm Lmin 6 5 cm 4A with Art 6620 2 1 5A with Art 6620 1 2 1 2 CLACK 8 1 2 DISASSEMBLY Art 6620 optional 160 cm 130 cm 2 2 1 3A with Art...

Страница 8: ...A 12V IN 2 1 IN 2 1 P F C L L P F C S S C N O N C 20 m MAX Connect a single call repetition device for each user code If inductive loads are connected the connection of 470nF capacitance in parallel w...

Страница 9: ...t DIP 8 of S2 to ON S2 1 2 3 4 6 7 5 8 S2 1 2 3 4 6 7 5 8 Power supply management For correct power supply management set S2 DIP 7 in accordance with the type of system and its configuration in system...

Страница 10: ...phone call PAN Priority call to switchboard not available in KIT systems NULL No function PROG With these S2 DIP switch settings the buttons control the programmed functions as in the Advanced config...

Страница 11: ...iguration table 4 Set the S1 DIP switches according to the call address of the desired apartment See Addressing table on page 17 5 Press and release the button to be associated with the function Corre...

Страница 12: ...g the next key by repeating the process from step 5 onwards 7 Exit programming mode by setting S2 DIP switch 6 to OFF LED switches off S2 8 Set S2 DIP switches 1 2 3 4 to ON 9 Return S1 DIP switches t...

Страница 13: ...g S2 DIP switch 6 to OFF LED switches off S2 7 Set S2 DIP switches 1 2 3 4 to ON 8 Return S1 DIP switches to the original combination 1 Take note of the S1 DIP switch settings 2 To enter programming m...

Страница 14: ...tch combination in which the desired functions corresponding to the buttons you want to program appear then set the S2 DIP switches Example For button 4 Self Activation AI and button 5 Call to Seconda...

Страница 15: ...is busy 2 Press and release Once 1 confirmation tone is emitted to change the ringtone for calls from the external entrance panel twice 2 confirmation tones are emitted to change the ringtone for call...

Страница 16: ...on the system type that best meets your requirements Simplebus2 audio video kit with power supply unit art 1209 for the creation of audio video systems for individual residences Simplebus2 audio vide...

Страница 17: ...8 14 2 3 4 44 3 4 6 74 2 4 7 104 4 6 7 134 2 3 8 164 3 6 8 194 2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 10...

Отзывы: