5.3. EX-700A w i r i n g an d set t i n g
PT1
PT2
DG1
DG2
OUT+
OUT-
DR2
DR1
POWER
<+>
<->
Main m onitor
Wiring t erm inal
Red
Bl ack
A. Wire t he system f rom term inal t o term inal accordingly.
1
Term inals for ex pansion m onit or (w/ polarit y)
Term inals from previous m onitor (w/ polarity)
Term inals for nex t m onit or (w/ polarit y)
Term inals for power adapter
Connect t o a N.C. m agnet ic swit ch sensor f or door st at us det ect ion.
1
2
PT1
PT2
IN+
IN-
OUT+
OUT-
POWER
<+>
<->
Ex pansion m onitor
wiring term inal
Red
Bl ack
To nex t
ex pansion m onit or
3
4
5
Magnet ic
swit ch
2
3
4
5
2 1
5.4. Jumper function on EX-700A
JP2
5.4.1. JP2, door status report options
A.PT1/ PT2 connect a N.C. switch sensor t o det ect door st at us and react as
JP2 options
B. Bell t one indicat ion (JP2 left ) (def ault)
C. LED light on Door Open But t on (JP2 right )