8
Main and secondary door entry monitors
A single 6741W (/BM) door entry monitor can be installed for each user code (apartment); this will also be the only main door
entry monitor
1209 / 1210 / 1210A / 4888C / 4888CU
6741W (/BM)
S2
1 2 3 4 6 7
5
8
Compatible secondary door entry monitors: art. 6601W, 6601W/BM, 6701W, 6701W/BM, 6701W/8, 6721W, 6721W/BM, 6801W, 6801W/BM.
Power Management
For correct power supply management, set
DIP 7 (S2)
according to the table.
With art. 6741W with a revision index [RR] greater than or equal to 12 and with art. 6741W/BM with a revision index [RR]
greater than or equal to 10: S2 DIP 7 should always be left set to ON (default), even in systems with 4888C and 4888CU.
with mixer
Art. 4888C/4888CU
with power supply unit
Art. 1210/1210A
with power supply unit
Art. 1209
6741W
RR < 12
ON
S2
1 2 3 4 6
7
5
8
ON
S2
1 2 3 4 6
7
5
8
6741W/BM
RR < 10
6741W
RR >= 12
ON
S2
1 2 3 4 6
7
5
8
6741W/BM
RR >= 1 0
aaRRVVT3016AA000360
aa
RR
VVT3016AA000360
aa
RR
VVT3016AA000360
< BACK