A.2.6.  Laser pointer 

 

 

 

 
During installation, the reflector is positioned with the help of the laser pointer built into the E / R. 
This pointing function is independent and does not require an external power supply. 
 
To activate the laser pointer: press the button and hold for more than a second, then release. 
To deactivate the laser pointer: press the button again. If the button is not pressed, it will deactivate automatically after 
20 minutes. 

A.2.7.  Securing the reflector 

Once  the  zone  indicated  by  the  laser  pointer  has  been  identified,  deactivate  the  pointer  or  block  the  laser  beam  to 
prevent it from reflecting into the eyes of the installer while it is fixed in place. 

Caution: 

 

The smooth surface of the safety reflector must be directed outwards. 

 

Switch off the pointer as soon as you have identified the point indicated by the laser beam. 

 
The reflector is secured in 2 steps: 

Step 1: 

securing the safety reflector support. 

  Use  screws  with  a  maximum  diameter  of  4  mm  to  secure 

the safety reflector support to the wall. 

 

 

Step 2: 

safety reflector coupling. 

  The smooth surface of the safety reflector must be directed 

outwards (i.e. towards the E / R). 

 

 

A.2.8 Securing the E / R part 

After  the  electrical  connections  have  been  carried  out  on  the  9-  and  10-pole  terminals,  fit  these  terminals  in  the 
corresponding positions on the back of the E / R. 
Encoding on the base (ref. 10 in the nomenclature) allows correct positioning when fixing the E / R part to the base. 

A.3. 

ELECTRICAL CONNECTIONS 

Once  the  base  has  been  fixed  to  the  wall,  carry  out  the  electrical  connections;  make  sure  you  use  a  power  supply 
which conforms to the electrical specifications contained in this manual. 
For information regarding electrical connections, please refer to the table below and the installation sheet at the end of 
this document. 
 

 

Содержание 48BFC000

Страница 1: ...1 OPTICAL BEAM LINEAR SMOKE DETECTOR WITH REFLECTOR 3 30 M 48BFC000 Please read this manual before using the equipment and keep it safe for future reference...

Страница 2: ...with national installation regulations Make sure both the detector and reflector can be accessed for commissioning and maintenance procedures A 2 2 Rules for the installation site The E R and the ref...

Страница 3: ...Securing the reflector 6 Deactivating the laser pointer press button Caution Leave a free area of at least 30 cm around each element installed on the wall A 2 4 Flush mounted base The flush mounted b...

Страница 4: ...ified the point indicated by the laser beam The reflector is secured in 2 steps Step 1 securing the safety reflector support Use screws with a maximum diameter of 4 mm to secure the safety reflector s...

Страница 5: ...2 x 0 5 mm2 cables are recommended for COM COM and TL TL respectively The K terminal is connected by means of a wire from a 2 x 0 5 mm2 cable COMMISSIONING A 4 MAIN STEPS Commissioning takes place by...

Страница 6: ...you press the button to deactivate the laser pointer make sure the detector and reflector are not exposed to direct sunlight Note If the orange light flashes after a succession of green pulses carry o...

Страница 7: ...ection rating E R part Flush mounted base IP 54 IP 41 Optical parameters Value Wavelength 940 nm Operating distance 3 to 30 m Max E R corner misalignment 0 35 Max reflector corner misalignment 5 Max E...

Страница 8: ...one B MAINTENANCE The specific equipment required for servicing the detector is A clean slightly damp cloth for cleaning the E R window and the reflector The alarm test filter to be positioned in fron...

Страница 9: ...9...

Отзывы: