Comelit 4682HD Скачать руководство пользователя страница 2

2

Table of contents

Warning ............................................................................................ 2

Description ....................................................................................... 3

Art. 4682HD - Compatibility table .......................................................3

Technical characteristics ................................................................ 5

External unit installation ................................................................. 6

Connections ..................................................................................... 7

Connection with POE power supply .......................................................7
Connection with additional power supply (Art. 1595)  ..........................7
Variants .....................................................................................................8

Module Connection ......................................................................... 9

External unit module consumption table ...............................................9
Connection of Ikall modules .................................................................10

Connection of button modules 33433, 33434, 33436, 33433M, 
33434M, 33436M ..............................................................................10
Connection of Art. 3360B, 3360BM ..................................................10

Connection of Vandalcom modules .....................................................11

Connection of Art. 3064S and Art. 1172B ........................................11
Connection of Art. 3188SB ...............................................................11
Connection of Art. 3070S, 3072S .....................................................12

Modules for Single-plate external unit .................................................12

Connection of Art. 3063D with additional power supply ..................12

Simplekey modules ................................................................................13

Connection of readers Art. SK9000I, Art. SK9001I ...........................13

Programming ................................................................................. 14

Assigning an index number to the “additional button modules” .......14
Addressing table ....................................................................................15
Device reset ............................................................................................16

Connection distances ................................................................... 17

Warning

Intended use

 

This Comelit product has been designed and manufactured for use in the creation of audio and video communication 

systems in residential, commercial, industrial and public buildings.

Installation

 

All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with 

careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.

Wires

 

Disconnect the power supply before carrying out any operations on the wiring. 

 

Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system 

manual.

 

We advise against running the system wires through the same duct as power cables (230V or higher).

Safe usage

 

To ensure Comelit products are used safely:

 

• carefully observe the indications provided in the Manuals / Instruction sheets,

 

• make sure the system created using Comelit products has not been tampered with / damaged. 

Maintenance

 

Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance 

with the indications provided in the Manuals / Instruction sheets.

 

Any repairs must be carried out:

   • for the products themselves, exclusively by 

Comelit Group S.p.A.

,

 

• for the systems, by qualified technical personnel.

Disclaimer

 

Comelit Group S.p.A. 

accepts no liability for

 

• any purpose other than the intended use,

 

• failure to observe the indications and warnings contained in this Manual / Instruction sheet.

 

Comelit Group S.p.A. 

reserves the right to change the information provided in this Manual / Instruction sheet at any 

time and without prior notice.

Содержание 4682HD

Страница 1: ...Passion Technology Design EN TECHNICAL MANUAL Audio video module for ViP system Art 4682HD...

Страница 2: ...ucts must be carried out by qualified technical personnel with careful observation of the indications provided in the Manuals Instruction sheets supplied with those products Wires Disconnect the power...

Страница 3: ...et all system requirements Art 4682HD Compatibility table Ikall Ikall Metal Vandalcom Roma 33410 33410M 3268S 0 32xx RI 33411 33411A 33411M 3268S 1 33412 33412A 33412M 3268S 2 For programming and conf...

Страница 4: ...D sound activated 11 Colour camera 12 Indicator LED lock release activated 1 Connector for 8 core wire for button module connection 2 JP1 manages the RC network for door lock filter on the relay conta...

Страница 5: ...utton function Yes HARDWARE CHARACTERISTICS Visual indications Yes Acoustic indications Yes Voice synthesis Yes ADJUSTMENTS Loudspeaker volume Yes via ViP Manager Mic volume Yes via ViP Manager GENERA...

Страница 6: ...long enough so as to allow easy programming of the audio video module L E D O F F LE D O F F WHITE OFF BLUE 6 Index the modules before proceeding with installation see Assigning an index number to th...

Страница 7: ...1440 L N V V OUT 4 3 OUT OUT 2 1 IN 2 1 IN OUT J1 J2 J1 J2 SE NC NO GND SE V V M O C R T E RX RX TX TX ORANGE WHITE ORANGE GREEN WHITE GREEN TX 4682HD 3268S J2 J1 C V S J1 J2 C V S J2 C V S J1 1172B 1...

Страница 8: ...n C NC contacts Excluded voltage free contact In case of replacement of a module previously installed with the Art 4682HD f f remove the existing terminal block and replace it with the terminal block...

Страница 9: ...stem configuration using the Consumption table External unit module consumption table Code Consumption Ikall modules 33433 33434 33436 33433M 33434M 33436M 0 4W 3336 3336M 0 4W 3339M 0 4W 3348B 3348BM...

Страница 10: ...N 2 1 IN OUT SE NC NO GND SE V V M O C R T E RX RX TX TX Connection of Ikall modules Connection of button modules 33433 33434 33436 33433M 33434M 33436M J1 J2 J1 J2 MAX 12 4682HD 1441 1440 L N V V OUT...

Страница 11: ...lb Art 1172B for nameplate lighting The bulb is polarised Use the cable supplied with Art 3268S Connection of Art 3188SB 4682HD 3268S C V S J2 J1 J1 J1 J2 C V S J2 C V S J2 J1 3188SB AL CK AC OUT D D...

Страница 12: ...Art 3072S Modules for Single plate external unit Connection of Art 3063D with additional power supply MAX 20 MAX 20 P 2 P 1 S C P 3 P 4 P 5 P 6 P 7 P 8 V J2 J1 J1 J2 3063D 3063D P 2 P 1 S C P 3 P 4 P...

Страница 13: ...1I RTE 12V 12V SK9000I NC D D C NO Ao Ai PB G D D SK9001I MAX 20 J1 J2 J1 J2 120 230 V 1595 4682HD 12 24V AC DC 1440 1441 L N V V OUT 4 3 OUT OUT 2 1 IN 2 1 IN OUT ORANGE WHITE ORANGE GREEN WHITE GREE...

Страница 14: ...are If the module has not yet been powered up carry out the necessary wiring and wait for the device to start running f f Wire the modules and buttons and power up the external unit after 10 sec the t...

Страница 15: ...44 3 4 6 74 2 4 7 104 4 6 7 134 2 3 8 164 3 6 8 194 2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 106 2 4 6 7 1...

Страница 16: ...16 Device reset The reset procedure restores the factory settings of the external units deleting all settings implemented by the installer 6 FAST BLINK 7 1 2 3 LED ON 10 SLOW BLINK 4 5...

Страница 17: ...00Mb IN 100Mb OUT 10Mb OUT 10Mb 6802W 6802B 6842W 6722W 6742W 1441 1441B 1440 4682HD MAX 150m 17 Connection distances If Art 4682HD is powered directly from third party standard POE switches the maxim...

Страница 18: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 2nd edition 06 2018 code 2G40002296 C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Отзывы: