Comelit 40799 Скачать руководство пользователя страница 28

22 

  

 

 
 

• WB (White Balance) CONTROL 

 

 

WB SETUP 

 

MODE 

AUTO 

R GAIN : 

210 

B GAIN : 

155 

EXIT(ESC TO EXIT) 

 

 
 
 

MODE: MANUAL / AUTO / INDOOR / OUTDOOR / ONE PUSH / ATW 
R GAIN: 0 ~ 255 
B GAIN: 0 ~ 255 
Use the ATW mode for normal use. 
R GAIN / B GAIN modes are controllable only in MANUAL Mode 
Push the Joystick to the right or left to change. 

 

NOTE : “ONE PUSH” means that when rotating the Joystick handle for a moment the lens moves 
to adjust the focus for the subject. The focus lens then holds that position until the Joystick 
handle rotation. 

 

 

• AE CONTROL 

 

 

 

AE

 

 

SETUP

 

 

MODE

  

 

: FULL AUTO

 

SLOW

 

SHUTTER

 

: AUTO

 

IRIS

  

: F2.4

 

GAIN

  

: 0 DB

 

BRIGHT 

: 14 

SHUTTER 

: 1/60 

EXIT(ESC TO EXIT) 

 
 
 
 

 

MODE: 

FULL AUTO / MANUAL / SHUTTER PRIO / IRIS PRIO / BRIGHT 

SLOW SHUTTER:   AUTO / MANUAL  ----- 

AUTO effect only FULL AUTO mode 

IRIS: 

CLOSE / F28 / F22 / F19 / F16 / F14 / F11 / F9.6 / F8.0 / F6.8 / F5.6 / 

F4.8 / F4.0 / F3.4 / F2.8 / F2.4 / F2.0 / F1.6 

GAIN: 

0 / 2 / 4 / 6 …… / 28 / -3 DB 

BRIGHT: 

0, 2, 3, 4 ..... 29, 30,31 

SHUTTER: 

1/1 , 1/2 , 1/4(3), 1/8(6). .. 1/4000(3500), 1/6000, 1/10000 

EXIT (ESC TO EXIT) 

 

NOTE : Values in (  ) are for PAL Camera. 

Содержание 40799

Страница 1: ...DAY NIGHT ALL IN ONE DOME CAMERA ART 40799 40800 Please read this manual thoroughly before use and keep it for future reference Via Don Arrigoni 5 24020 Rovetta S Lorenzo Bergamo http www comelit it E...

Страница 2: ...ightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of suffici...

Страница 3: ...E TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPEN...

Страница 4: ...nt of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachmen...

Страница 5: ...Setting Dome Camera Protocol 7 2 7 Connections 8 2 8 Getting Started 10 Chapter 3 Program and Operation 11 3 1 Dome Camera Selection 11 3 2 Accessing On Screen Menu Utility 11 3 3 How to control On Sc...

Страница 6: ...tup 28 OSD Display 29 View Direction 29 Dome OSD Display 29 Area Display 29 View Angle Setup 30 Panning Range 30 Flip 30 Tilt Over Angle 30 Initialize Data 31 Origin Offset 31 Dome Reset 31 System Inf...

Страница 7: ...set positions 4 Tours consist of Preset Pattern Auto Scan can be programmed 4 Auto Scans including vector scan and 1 Endless Auto Scan 2 Patterns 60 second 8 Privacy zones 4 Alarm inputs 1 relay outpu...

Страница 8: ...2 Figure 1 Typical System Configuration...

Страница 9: ...eiling mount to install The wall or ceiling mount must be attached to a structural object such as hard wood concrete that will support the weight of the mount and AIO The use of a solid backboard is r...

Страница 10: ...c Configuration of Dome Camera System Figure 2 Basic Installation Diagram The dome camera must be installed by qualified service personnel in accordance with all local and federal electrical and build...

Страница 11: ...5 Figure 3 Layout of Switches...

Страница 12: ...etting Dome Camera Address ID To prevent damage each dome camera must have a unique address ID When installing multiple dome cameras using a multiplexer it is suggested that the dome camera address ma...

Страница 13: ...oard controller select F2E protocol Consult service personnel if a dome camera is installed with device other than a keyboard controller S4 S3 on 1 2 3 4 S4 D1 D2 D3 D4 PROTOCOL OFF OFF OFF OFF F2 F2E...

Страница 14: ...AC 24V 2 2A for the heater and the fan Use certified Listed Class 2 power supply transformer only Connector 3 AL1 AL2 AL3 AL4 G Alarm In You can use external devices to signal the dome camera to react...

Страница 15: ...LACK NO ALARM OUTPUT CONNECTOR 1 AC AC G R R G CONNECTOR 2 F F COLOR DESCRIPTION RED AC AC 24V ORANGE AC AC 24V YELLOW G GND GREEN R GRAY R BLUE G GND CONNECTOR 3 AL1 AL2 AL3 AL4 G CONNECTOR 4 COM NC...

Страница 16: ...ion is displayed on the monitor FASTRAX IIL Vx xxx CAMERA TYPE xxxx WAIT DOME SETTING INIT TILT ORGIN SET OK INIT PAN ORGIN SET OK INIT CAMERA SET OK PRESET No PRESET TITLE or AREA TITLE INFORMATION D...

Страница 17: ...ill select dome camera 10 The selected dome camera ID will be displayed on the LCD monitor of the keyboard controller 3 2 Accessing the On Screen Menu Utility You can call up the On screen menu utilit...

Страница 18: ...Auto Scan First Item of the Main menu Shortcut SCAN The Auto scan supports up to 4 programmed angles at user programmable speeds Follow these steps to program Auto Scan AUTO SCAN SETUP SCAN 01 AUTOSCA...

Страница 19: ...nward to select Speed and set the speed by twisting the Joystick clockwise or counterclockwise 7 Select Save and Exit by pushing the Joystick to the right Press ESC to exit the program without saving...

Страница 20: ...MENU to display the main menu Select the Preset option by using the Joystick to the right Press Prst to go directly to the Preset menu without going through the main menu 2 Select the blank preset po...

Страница 21: ...om and focus then press No 1 to 128 and then press PGM PRST subsequently The current view will be stored to the selected preset number if position is empty If selected preset number is not empty PRESE...

Страница 22: ...ress Zoom Key Programmed preset will scroll To remove a stored preset from the Tour press the Home key blank position mark will be displayed You can overwrite the programmed position 5 To place functi...

Страница 23: ...in menu on the monitor 2 Scroll down to PATTERN and push the Joystick to the right Or simply press the PTRN key rather than use the Main Menu 3 Select the empty Pattern number to be programmed by push...

Страница 24: ...ity can be selected Preset only During responding 0 priority alarm other alarms won t be serviced until the 0 priority action is completed 1 Press Menu to display the main menu on the monitor Select t...

Страница 25: ...to enter the detail menu 2 Select the area number by pushing the Joystick up or down Select Start End or number column to be set by pushing the handle to the right or left The selected column will be...

Страница 26: ...dle clockwise or counterclockwise You can select alphanumeric characters by rotating the handle Move to the next character position by pushing the Joystick to the right To finish entering the title pu...

Страница 27: ...imited to the optical 2x Zoom is extendable up to 2x of digital range 4x Zoom is extendable up to 4x of digital range MAX Zoom is extendable Max digital zoom range FOCUS CONTROL FOCUS SETUP MODE AUTO...

Страница 28: ...ves to adjust the focus for the subject The focus lens then holds that position until the Joystick handle rotation AE CONTROL AE SETUP MODE FULL AUTO SLOW SHUTTER AUTO IRIS F2 4 GAIN 0 DB BRIGHT 14 SH...

Страница 29: ...ared NIGHT SHOT SETUP MODE MANUAL LOCAL CONTROL OFF EXIT ESC TO CANCEL MODE MANUAL AUTO GLOBAL AUTO Camera goes in to B W mode at low light GLOBAL Controlled by the keyboard The operator can enable NI...

Страница 30: ...is because a sufficient amount of aperture is not available due to the CCD size and the lens structure of this model However it has been verified that the eclipse will not be visible in the case of a...

Страница 31: ...picture will be enhanced User can adjust sharpness level from 0 to 20 Level 20 is default BACK LIGHT Objects in front of bright backgrounds will be clearer with BLC ON DIGITAL ZOOM OFF Zoom range is l...

Страница 32: ...ON MANUAL MODE ONLY IRIS F1 6 F2 0 F2 8 F4 0 F5 6 F8 0 F11 F16 F22 F32 GAIN OFF 2 4 6 8 10 12 14 16 18 20 DB BRIGHT User can adjust brightness level 0 90 Level 30 is default SHUTTER 1 1 1 2 1 3 1 6 1...

Страница 33: ...ared NIGHT SHOT SETUP MODE MANUAL LOCAL CONTROL OFF EXIT ESC TO CANCEL MODE MANUAL AUTO GLOBAL AUTO Camera goes in to B W mode at low light GLOBAL Controlled by the keyboard The operator can enable NI...

Страница 34: ...ted follow the directions below to set the function HOME FUNCTION SETUP HOME FUNCTION NONE FUNCTION NUMBER WATING TIME 120 SEC FUNCTION ENABLE OFF SAVE AND EXIT ESC TO CANCEL HOME FUNCTION None Preset...

Страница 35: ...t OSD DISPLAY DISPLAY SETUP CAMERA TITLE DOMEID VIEW DIRECTION OFF DOME OSD DISPLAY ON AREA DISPLAY OFF SAVE AND EXIT ESC TO CANCEL CAMERA TITLE 8 CHARACTER CAN BE SET VIEW DIRECTION ON OFF DOME OSD D...

Страница 36: ...the same as previous OFF when the camera reaches the floor directly above the moving object it will stop TILT OVER ANGLE This option is used to set the limit of the horizontal view angle so that the...

Страница 37: ...camera can be stored in the keyboard controller temporarily ORIGIN OFFSET This feature is useful to align a new dome camera exactly the same as the previously installed dome camera Dome camera s orig...

Страница 38: ...Illumination 1 0 lux normal shutter 0 02 lux 1S slow shutter 0 002 lux ICR ON 1S slow shutter S N ratio more than 52dB Camera art 40799 Image Sensor 1 4 Ex view CCD Picture elements NTSC 768 x 494 App...

Страница 39: ...ight Approx 3 3 kg Features Pan Angle 360 continuous rotation 0 1 to 90 sec proportional to zoom 360 sec maximum with CTRL PGM key pressed Speed Preset Speed 360 sec Flip Rotate 180 art 40799 Digital...

Страница 40: ...34 Figure 6 Dimensions...

Страница 41: ...o video Verify that power is connected to all pieces of equipment in the system Verify that the power switches are in the ON position Check the video connections Poor video quality Check that the BNC...

Страница 42: ...creen Menu The text overlay menu system used for setting dome features The utility is accessed using a keystroke combination The utility provides settings for camera functions zoom alarms text display...

Страница 43: ...t State Describes the expected state of a device connected to one of eight dome camera s inputs The normal state may be open or closed When a device is not in its normal input state an alarm is issued...

Страница 44: ...elds high and normal every 60th or 50th of a second and combines two fields into one progressive scan frame It allows every detail to be captured accurately even if one portion of an image is brillian...

Страница 45: ...12 ON Digital Zoom on According to digital zoom setting 12 OFF Digital Zoom off 13 ON Dome OSD on 13 OFF Dome OSD off 14 ON Dome Area Title Display on 14 OFF Dome Area Title Display off 15 ON View Di...

Страница 46: ...te cables through a section of 0 75 in 19mm conduit pipe 4 Remove the access plate from the wall mount bracket 5 Attach the wall mount bracket using screws routing cables through the access plate s ho...

Страница 47: ...from the ceiling 4 Attach the ceiling mount bracket using screws routing cables through the locking nut 5 Tighten the housing with the pipe using the socket after routing cables through the pipe 6 At...

Страница 48: ...Via Don Arrigoni 5 24020 Rovetta S Lorenzo Bergamo http www comelit it E mail export department comelit it...

Отзывы: