Comelit 1998VC Скачать руководство пользователя страница 4

4

Description

 1.

 Message indication display

 2.

     Menu option navigation keys

  3. CANC

 Key used to cancel a call or delete entered data

 4. 

 Menu navigation keys

  5. ESC

 Exit menu key

 6. 

 Key activating self-ignition

  7. OK

 Confirm key

  8. ON/OFF

 Power on/off (press and hold for 2 seconds)

 9. 

   Key activating DAY or NIGHT mode

10. MENU

 key

11.

 

 Call key

12.

 

 Lock-release key

13.

 

 Follow Me key

14.

 

 Call hold key 

15.

 

 Key for calling the Simplebus Top switchboard from 

the Simplebus switchboard

16.

 

 Key used to activate an additional relay

17.

 Wheel for call volume adjustment

18.

 Alphanumeric keypad

19. 

 Directory key

20. 

 Speed numbers

21. 

Handset

Do not press and hold the audio hook while 

the handset is lifted

Description of terminal block:

C NO

 Normally open contact for “FOLLOW ME” function

24 ~

 

24 V AC power supply

0 ~ 

0 V AC power supply

 Earthing

OUT OUT

 CNO output for remote camera control

CH CH

 Free contact for “call repeat” or “enable external 

monitor”  

LM LM

 Data line to risers

LP1 LP2

 Incoming data line from external unit

GND TX RX 

RS232 serial port for connection to the 

remote switchboard in systems with multiple 

switchboards in series or in parallel.

The porter switchboard in its desk version with alphanumeric digital keypad and 3.5” colour display, for viewing visitors and 

controlling entrances. Allows the code and name of the called and calling users to be displayed, keeping unanswered calls 

stored in the memory. Day/Night mode and user/user intercom service. Allows call addressing for up to 120000 users. It allows 

call transmission with indirect codes, management of alarm indications originating from users. Can be used as a main or 

secondary switchboard. Up to 4000 names can be stored. Equipped with USB port, special PC SW for downloading names 

and bushing for connection to the disconnectable system via RJ cable. Compatible with all SBTOP functions and products. 

0

1

2

3

4

5

6

7

8

9

#

ABC

DEF

MNO

JKL

GHI

WXYZ

TUV

PQRS

ON/OFF

MENU

ESC

OK

CANC

4

10

8

1

2

3

4

5

6

7

8

1

9

11
12

13
14

3

2

7

5 6

18

20

21

16

15

19

17

Содержание 1998VC

Страница 1: ...EN TECHNICAL MANUAL Porter switchboard Art 1998VC Passion Technology Design...

Страница 2: ...s the power cables 230V or higher Safe usage To ensure Comelit products are used safely carefully observe the indications provided in the Manuals Instruction sheets make sure the system created using...

Страница 3: ...dditional relay e g to activate independently using a specific command lights CCTV alarm contacts vehicle barriers entrances without an external unit or other devices 13 U15 How to use the directory 1...

Страница 4: ...r enable external monitor LM LM Data line to risers LP1 LP2 Incoming data line from external unit GND TX RX RS232 serial port for connection to the remote switchboard in systems with multiple switchbo...

Страница 5: ...ing indicates malfunctioning of the serial line 10 LM flashing indicates a short circuit on the riser line the text is accompanied by a tone which sounds repeatedly The switchboard rejects any attempt...

Страница 6: ...ch could not be answered are stored a DIRECTORY which can be programmed so as to identify the caller easily Technical features MAIN FEATURES Height mm 130 Width mm 200 Depth mm 223 Operating temperatu...

Страница 7: ...L UNIT 1998VC 1195 1 2 1 2 0 2 3 0 0 2 4 LP 1 24 0 L M L M C H C H LP 2 O U T O U T T X R X G N D C NO RS 232 FOR DOWNLOADING NAMES IN DIRECTORY VIA 1249 A Free contact for CALL REP or ENABLE EXTERNAL...

Страница 8: ...mode in NIGHT mode it will only answer direct switchboard calls The switchboard can receive a call from an external unit addressed directly to an internal unit in which case the NAME of the called un...

Страница 9: ...n is equal to the audio time set on the main switchboard MENU Settings Timers Audio min 10 seconds max 90 seconds U4 How to transfer a call from the external unit to an internal unit When the switchbo...

Страница 10: ...ith internal unit 003 and press to resume communication with internal unit 002 14 15 26 Lun 12 Mar 12 In comunicazione con 002 f f to end the conversation hang up the handset CAUTION If the external u...

Страница 11: ...e call has not taken place correctly 14 15 26 Mon 12 Mar 12 User not available if the system is busy 14 15 26 Mon 12 Mar 12 Line busy When the handset of the switchboard called is lifted it communicat...

Страница 12: ...hboard 14 15 26 Mon 12 Mar 12 Switchboard call f f to answer the call coming from the main switchboard lift the handset f f to end the conversation hang up the handset CAUTION If the switchboard is bu...

Страница 13: ...nu press OK 14 15 26 Mon 12 Mar 12 Settings Configurations Directory Received calls Alarms 2 use the keys to view the Services menu press OK 14 15 26 Mon 12 Mar 12 System Services 3 use the keys to vi...

Страница 14: ...Mar 12 ________________________ Sergio Rossi Code 012 Scroll Menu Or f f enter the name even using just part of the extension If there are several users with the same initial you can scroll through t...

Страница 15: ...nu Or 1 enter the name even using just part of the extension If there are several users with the same initial you can scroll through the list using the keys 14 15 26 Mon 12 Mar 12 ____________________...

Страница 16: ...te all Info a screen will appear asking if you wish to delete the entire directory confirm using OK or cancel using ESC Delete All Ok Esc f f press ESC repeatedly to return to the main screen U21 Dire...

Страница 17: ...Mar 12 Settings Configurations Directory Received calls Alarms 2 use the keys to view the View entry press OK 14 15 26 Mon 12 Mar 12 View Delete all the calls received and made are displayed in chron...

Страница 18: ...ry press OK 14 15 26 Mon 12 Mar 12 View Delete all the calls are displayed in chronological order beginning with the most recent call received use the keys to scroll through the list To speed up scrol...

Страница 19: ...larm Alarm 1 Key tone Date Year 2010 Month Marzo Day 12 Time Hours 14 Minutes 15 Seconds 26 Daily mode Enable Sun Night Mon Night Tue Night Wed Night Thur Night Fri Night Sat Night Skins Reset setting...

Страница 20: ...ations Directory Received calls Alarms 2 use the keys to view the Video menu press OK 14 15 26 Mon 12 Mar 12 Language Video Audio Tones Date 3 use the keys to view the video setting you wish to adjust...

Страница 21: ...5 26 Mon 12 Mar 12 External Spring Internal Spring Alarm Alarm 1 Key tone Esc Ok 4 select the melody using the keys 5 Activate the Tone service using the key Disable it using 6 press OK to confirm the...

Страница 22: ...ress OK 14 15 26 Mon 12 Mar 12 Tones Date Time Skins Timers 3 use the keys to view the setting you wish to adjust audio reset wait time standby relay activation call repeat and decrease or increase th...

Страница 23: ...3 00 22 00 Day mode operation 14 15 26 Mon 12 Mar 12 Swt1 07 00 Day Swt2 12 00 Night Swt3 13 00 Day Swt4 22 00 Night Esc Ok 1 press the MENU key and use the keys to view the Settings menu press OK 14...

Страница 24: ...2 Mar 12 Skins Timers Daily mode Automatic switching Reset settings 3 a screen will appear asking if you wish to reset the settings confirm using OK or cancel using ESC 14 15 26 Mon 12 Mar 12 Timers M...

Страница 25: ...he LS LS line of switching device Art 1424 as Parall LS IN set the switchboard located under the LPin LPin line of switching device Art 1424 as Parall LP IN For the parallel switchboard switching to N...

Страница 26: ...ESC repeatedly to return to the main screen C4 Call via Simplebus or indirect code This function can be used to select the manual switchboard calling mode from the 2 options available 1 Simplebus cal...

Страница 27: ...calling will allow you to make a video call to an internal unit The monitor called by the switchboard will switch on making it possible to view for example the images from the remote cameras connected...

Страница 28: ...is function can be used to activate or deactivate the triple call made by the switchboard to the internal units The call will therefore take place on consecutive occasions in the case of video calls t...

Страница 29: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 2 nd edition 06 2019 cod 2G40002109 C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Отзывы: