Comelit 1259C Скачать руководство пользователя страница 6

6

2. Coded actuator mode

3. Mode with external audio unit

Before programming the module, see 

“5. Compatibility table for Art. 1259C”

.

In this mode and with the door entry phone monitor switched on, by repeatedly pressing the button programmed as “

coded 

actuator

”, it is possible to cycle through ONLY the cameras connected to Art. 

1259C

 with the corresponding address.

 

f

To activate the function, program the button on the monitor as coded actuator (with address between 220 and 227 

inclusive) and set selector “

S1

” as illustrated in the table below:

Generic/coded actuator modes can also be used on a system which includes an audio-only external unit 

Art. 1622

For operation with “audio only” external unit:

 1. 

set DIP 1 of selector “

S1

” as illustrated below:

 2. 

set the external unit to video mode as shown in the picture below:

12

34

56

78

ON

DIP

In this mode, every time a call is received from the external unit or when self-ignition takes place, the monitor switches on and 

displays the image from the first camera connected to Art. 

1259C

. It will be possible to cycle through all cameras connected by 

repeatedly pressing the programmed button.

Up to 8 modules Art. 1259C with 8 different codes can be installed in the same system.

Example for setting address on Art. 1259C for control by means of actuator code 224

S1

1259C address-coded actuator correspondence

DIP 1

DIP 2

DIP 3

DIP 4

DIP 5

DIP 6

Address 1259C

Actuator code on monitor

1

0

0

0

0

0

0

220

1

0

1

0

0

0

1

221

1

0

0

1

0

0

2

222

1

0

1

1

0

0

3

223

1

0

0

0

1

0

4

224

1

0

1

0

1

0

5

225

1

0

0

1

1

0

6

226

1

0

1

1

1

0

7

227

Содержание 1259C

Страница 1: ...EN TECHNICAL MANUAL Module for SBTOP remote camera module Art 1259C Passion Technology Design...

Страница 2: ...s the power cables 230V or higher Safe usage To ensure Comelit products are used safely carefully observe the indications provided in the Manuals Instruction sheets make sure the system created using...

Страница 3: ...a 3 IN A Camera module external control contact GND Common contact 2 Programming microswitches S1 3 Terminal block MR1 for system connection L OUT L OUT BUS line output L IN L IN BUS line input 12 Vac...

Страница 4: ...4 Connection CAMERA CONTROL KEY 1259C 1200 12V 230V G N D A N I 3 V S 3 2 S V 2 S 1 1 V L L L OUT L OUT IN IN VIDEO ENTRY SYSTEM RISER VIDEO ENTRY SYSTEM RISER Requires separate power supply...

Страница 5: ...E MODE WITH AUDIO PORTER OR SWITCHBOARD In this mode and with the door entry phone monitor switched on it is possible to cycle through all the connected cameras by repeatedly pressing the button progr...

Страница 6: ...al unit 1 set DIP 1 of selector S1 as illustrated below 2 set the external unit to video mode as shown in the picture below 1 2 3 4 5 6 7 8 O N D I P In this mode every time a call is received from th...

Страница 7: ...e OUT OUT terminals of the switchboard you will be able to cycle through all available cameras f f To use this function the remote camera module must be connected to the outgoing Bus line from termina...

Страница 8: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 6 edizione 10 2018 cod 2G40002083 C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Отзывы: