6
2. Coded actuator mode
3. Mode with external audio unit
Before programming the module, see
“5. Compatibility table for Art. 1259C”
.
In this mode and with the door entry phone monitor switched on, by repeatedly pressing the button programmed as “
coded
actuator
”, it is possible to cycle through ONLY the cameras connected to Art.
1259C
with the corresponding address.
f
To activate the function, program the button on the monitor as coded actuator (with address between 220 and 227
inclusive) and set selector “
S1
” as illustrated in the table below:
Generic/coded actuator modes can also be used on a system which includes an audio-only external unit
Art. 1622
.
For operation with “audio only” external unit:
1.
set DIP 1 of selector “
S1
” as illustrated below:
2.
set the external unit to video mode as shown in the picture below:
12
34
56
78
ON
DIP
In this mode, every time a call is received from the external unit or when self-ignition takes place, the monitor switches on and
displays the image from the first camera connected to Art.
1259C
. It will be possible to cycle through all cameras connected by
repeatedly pressing the programmed button.
Up to 8 modules Art. 1259C with 8 different codes can be installed in the same system.
Example for setting address on Art. 1259C for control by means of actuator code 224
S1
1259C address-coded actuator correspondence
DIP 1
DIP 2
DIP 3
DIP 4
DIP 5
DIP 6
Address 1259C
Actuator code on monitor
1
0
0
0
0
0
0
220
1
0
1
0
0
0
1
221
1
0
0
1
0
0
2
222
1
0
1
1
0
0
3
223
1
0
0
0
1
0
4
224
1
0
1
0
1
0
5
225
1
0
0
1
1
0
6
226
1
0
1
1
1
0
7
227