DAMPER TYPES
Damper assemblies are to be installed as per layout
drawing. Each burner flow must be equipped with a
damper assembly so that accurate vacuum settings can
be made.
NOTE:
Install all damper handles so that they face
downward. The damper handle can be rotated by
removing the two nuts, which hold the blade, and setting
plate in place. Rotate setting plate 180° and reassemble -
take care so as not to "strip out" handle. When turning the
damper handle, the retaining spud on the opposite side
should rotate simultaneously.
NOTE:
0641.00 damper assembly for use with single
burner systems and when DAMPER TEE'S are not used.
Install Handle On Side, Or Bottom Of
Tube (Position locating holes as shown)
0441.00 DAMPER ASSEMBLY
0407.AS.C - Damper
Single
Burner Flow
To Vacuum Exhauster
Single
Burner Flow
0407.AS.B - Damper TEE
Single
Burner Flow
To Vacuum Exhauster
Single
Burner Flow