43
EN
EN
6.10 Errors that can be displayed
List of ERRORS that can be displayed, with the button (7) red steady/blinking:
- Errors 01, 05, 09, 10, 11, 12 are critical (button 7 steady red) and shut down the machine
completely. To reinstate the machine, request technical assistance. To reset these errors, the PCB
must be switched off and then on again (ON-OFF button 1).
- With errors 02, 03, 04, 06, 07 and 08 the button 7 continues to blink red until the error is reset
(press the button 3). If the problem persists, request technical assistance.
- With error 13 the machine goes to the first installation sequence. It is necessary to request the
assistance of a technician who must enter the machine mode.
42
Alarm 01
Alarm 02
Alarm 03
Alarm 04
Alarm 05
Alarm 06
Alarm 07
Alarm 08
Alarm 09
Alarm 10
TANK FILLING
BOILER HEATING
TANK HEATING
TANK
DRAINING
BOILER FILLING
BOILER PROBE
TANK PROBE
Thermostop
TIME-OUT
BOILER SAFETY
SW
TANK SAFETY
SW
No TANK filling
No BOILER heating
No TANK heating
No TANK draining within
time-out
No BOILER filling
Boiler probe temperature
outside range
Tank probe temperature
outside range
Thermostop time-out
before rinse
Boiler safety thermostat
intervention
Tank safety thermostat
intervention
- Water tap does not
deliver water;
- Overflow incorrectly or
not inserted;
- Rinse arm nozzles
clogged;
- Inlet pipe constricted
Request
technical
assistance
Request
technical
assistance
- Check cleaning of filters;
- Make sure the drain hose
is not blocked or pinched;
- Water supply tap does
not deliver water;
- Inlet pipe constricted
Request technical
assistance
Request technical
assistance
Request technical
assistance
Request technical
assistance
Request technical
assistance
- Solenoid valve faulty
or clogged;
- Boiler clogged;
- Pressure switch faulty;
- Air cage clogged
- Heating element faulty;
- Check possible contactor
Heating element faulty;
Drain pump blocked by
a foreign body or faulty
- Solenoid valve faulty
or clogged;
- Pressure switch faulty
Check boiler
temperature probe
Check tank temperature
probe
- Boiler heating element
faulty;
- Check possible contactor
Check boiler safety
thermostat
Check tank safety
thermostat
Alarm
number
Display Message
Description
User checks
Installer checks
RED
STEADY/BLINKING
7
1
3
ALARM 02
HEATING BOILER
Alarm 12
Alarm 13
Alarm 15
PANEL
CONNECTION
PARAMETER
ERROR!
SERVICE
WARNING
No communication with
board
The parameters have been
compromised
The cycles for performing
maintenance have been
exceeded
Request
technical
assistance
Request
technical
assistance
Request
technical
assistance
Check board cable
connections
Do the sequence before
installation by entering
the four-digit machine
code
Do a warewasher
maintenance/check
Содержание 7280.0070
Страница 70: ...139 138 RU RU 1 10 C 50 C 10 C 25 C ES S 200 500 2 5 100 500 1 5 PRS 5 20 f 2 8 11 d f d 2 2 1 2 2...
Страница 71: ...141 140 RU RU 2 3 MODEL TYPE CODE S N 400 V 3N 50 Hz Power IPX2 Electronic code PW 2 4 2 5 2 6 2 7...
Страница 72: ...143 142 RU RU 70 dB A 3 1 2 3 4 5 6 7 8 3 1 P K 4 3 40 4 1 5 C 40 C PRS 1 2 3 6 7 8 5 4...
Страница 73: ...145 144 RU RU 4 2 10 4 3 100 500 1 5 200 500 2 5 20 f 4 3 4 10 C 50 C ES 25 800 4 4 30 3 10 10...
Страница 74: ...147 146 RU RU 4 5 5 5 1 1 2 3 4 5 6 7 8 5 2 1 2 2 3 3 4 5 6 7 OFF 8 V 5 5 C B 8 2 C 60...
Страница 75: ...149 148 RU RU 6 6 1 4 3 6 2 3 0 0 12 0 0 82 0 82 0 12...
Страница 80: ...159 158 RU RU 9 7 6 1 25 2 8 3 SERVICE WARNING A B A B C D A A 55 D E F A B C D A B C D E F 80 85 A B C D E...