Cleaning and Maintenance 

 

 

 

Make sure all taps are closed. If possible, close the valve connected to the device 
inlet.  

 

Let the appliance cool down first. Remove coarse dirt with a dry cloth.. 

 

Check the Oil Drawer frequently during cooking. Do not pour used oil into the sink. 

 

If possible, dispose of the oil in an irreversible garbage (non-recyclable) or in 
accordance with the regulations in your country. 

 

Clean with a warm soapy cloth. 

 

Do not use abrasive cleaning agents such as stains or rust removers and hard surface 
sponges.. 

 

Always dry your device with a clean cloth after every wet cleaning. 

 

• Do not use chemicals or steel cleaning agents. Remove dirt immediately. Dirt that 
remains for a long time can damage the surfaces of your device. 

 

Clean your appliance regularly, if possible, after each cooking process..  

 

Do not wash the appliance with high pressure water or steam. 

 

What to do in case of failure? 

                

                 

During Breakdown      

 

 

 

Repairs  should  only  be  carried  out  by  an  Authorized  Service  Agent.  Incorrect 
repairs carried out by unauthorized services may present a hazard to the user.. 

 

During maintenance, the main gas valve must be kept closed and the device 
should not be approached with fire. After repair or replacement of parts, a 
tightness test must be carried out, using a foam or gas detector. In case of a 
dangerous situation, contact the authorized service.

 

Do not allow unqualified 

persons to interfere with the device. 

 

Dangerous: Never allow the flame check to be carried out with flame

 

 

 

FAULT

 

REASON 

 

SOLUTION

 

The appliance does not cook stable. 

Some of the burners being clogged. 

Close the gas valve. Clogged burner holes of the device should be 

cleaned by qualified persons with water and the device should be 

cleaned after each use. 

The screw of the gas tap is worn.. 

The gas tap must be replaced by the technical service.. 

Leakage in gas installation. 

The gas connection must be checked by a technical service.

 

There is a leak in the gas inlet fittings. 

Technical service should be called.

 

Clogged injectors. 

 Cleaning the gas valve by removing the injector in.

 

the gas circuit by qualified persons.

 

There is sediment in the gas used. 

Technical service should be called

 

The smell of gas in the room 

Do not burn the appliance even though  

the gas connection is made. 

 