After gas inlet connection is completed, check for possible gasleakages.
Feed the device with the gas and pressure as specified on device information plate and adjusted. If the
gas type to which the device was adjusted for is not suitable to the gas type at the mounted place, follow
the instructions writtenbelow.
ATTENTION:
All adjustments and modifications to be performed on the gas
installation and connection of the device should be performed by authorized people.
Gas pressure may never exceed 21mbar for Natural gas and 30mbar for LPG.
START-UP
Turn the main gas valve to openposition.
Turnthegrillgasbutton(5)tolighterposition
”bypushingitgently.Inthisposition,ignite
(6) the burner with lighter.
After the burner is ignited, keep the button pressed for a few seconds (min. 10) to heat the safety
thermocoupleend.
Later,youcanadjustittothedesiredpositionbyturningtohighflame
”orlowflame“
”
marks indicated onbutton.
If the device is operated for the first time, keep the button pressed at burner flame position for a while
before ignition to discharge the air in the gasinstallation.
TURNING OFF
Turn the gas button to lighter position
”. Turn to position “0” to turn offcompletely.