It will reset PA and then re-detect the PA output power and reflected power, if they are normal, the PA
Service Status will turn to
Normal
, if PA output power or reflected power is still over the threshold, PA
Service Status will turn to
Recovery
again.
If PA output power or reflected power is still over the threshold after six times of PA Recovery, PA
Service status will be
Shutdown
which will need to be reset manually. Reset at Management > PA
Reset.
Click on a specific band on the left side of RU Device page, the corresponding band information will show.
Figure 50: RU Device
– 850MHz
5.2.2 [COMMISSIONING]
A work flow of the commissioning process is shown on [Commissioning] page. Click the [Start] button, the
software will guide you through the commissioning step by step. For details, please refer to chapter 5.3.
Figure 51: [Commissioning] Screen
Select
850MHz
band
850MHz RF
parameter setting table
850MHz alarm information
and configuration table