USER MANUAL FOR COMFLEX-4500 5W

 

ENU STATUS : 1-0-0 

Copyright - refer to title page 

Page 31 

 

3.4 

EQUIPMENT CONNECTORS 

The figures below present the connectors of ComFlex MU. 

1

2

3

4

5

6

7

8

 

 

Figure 27: MU Front Panel Connectors 

 
 
 

 

13

12

11

10

9

14

15

16

17

18

19

20

21

22

23

 

 

Figure 28: MU Rear Panel Connectors 

 

Содержание MRU-4500

Страница 1: ...M ME ED DI IU UM M PO OW WE ER R D DI IS ST TR RI IB BU UT TE ED D A AN NT TE EN NN NA A S SY YS ST TE EM M MRU 4500 USER MANUAL MRU 4500 5W QE 1 0 0 Comba Telecom Ltd...

Страница 2: ...in which vests in Comba International Comba All rights reserved The information contained herein is confidential and the property of Comba and is supplied without liability for errors or omissions No...

Страница 3: ...NG CONSIDERATIONS 17 3 3 INSTALLATION PROCEDURES 19 3 4 EQUIPMENT CONNECTORS 31 3 5 EQUIPMENT CONNECTION 34 4 COMMISSIONING 39 4 1 PRE COMMISSIONING TASKS 39 4 2 LED INDICATORS 39 4 3 DIGITAL DISPLAY...

Страница 4: ...tion 29 Figure 24 Remote PSU installed on the right of RU 29 Figure 25 Mounting Rack Installation Unit inch 30 Figure 26 Remote PSU wall mounting 30 Figure 27 MU Front Panel Connectors 31 Figure 28 MU...

Страница 5: ...59 Figure 74 Commissioning Procedure Params Setting 59 Figure 75 Dev Info Date Time 60 Figure 76 Flow to select 60 Figure 77 Calibration screen 61 Figure 78 Commissioning Procedure Automatic Calibrat...

Страница 6: ...MFLEX 4500 5W ENU STATUS 1 0 0 Copyright refer to title page Page 6 0 3 HISTORY Change No ENU Details Of Change 1 1 0 0 This user manual first created in Oct 2014 which referred to its Chinese manual...

Страница 7: ...rminal MTBF Mean Time Between Failures MU Master Unit NC Normally Closed NF Noise Figure NO Normally Open OMC Operation Maintenance Center OMT Operation Maintenance Terminal WebOMT Web Operation Maint...

Страница 8: ...xt label may accompany the symbol label Hazard labeling is supplemented by safety notices in the appropriate equipment manual These notices contain additional information on the nature of the hazard a...

Страница 9: ...he low signal transmission loss of optical fiber is applicable for long distance transmission ComFlex 4500 can support the optical transmission of up to 6 5dBo optical loss equivalent to 8 miles fiber...

Страница 10: ...USER MANUAL FOR COMFLEX 4500 5W ENU STATUS 1 0 0 Copyright refer to title page Page 10 Figure 2 Remote Unit RU and RU PSU End of Section...

Страница 11: ...The Optical TX RX Module of RU converts the DL optical signals into RF signals After amplification the signals are transmitted at the ANT port to the service antenna On the UL the signals transmitted...

Страница 12: ...s optical signal and RF signal conversion One FOU has four optical ports which means each FOU can support up to four RUs MU01 RFU Master Unit RF Unit RFU completes separation and combination of uplink...

Страница 13: ...the following part Table 2 RU Components Module Description MRU01 4500 Remote Unit A compact and slim design which supports 4 bands including 850MHz 1800MHz 2100MHz and 2600MHz bands LRU01 PSU A92W300...

Страница 14: ...le 3 Master Unit MU KOP Item Qty Image MU Chassis 1 RF Unit RFU 1 8 Fiber Optical Unit FOU 1 2 FOU Dummy Load 0 1 RFU Dummy Load 0 6 Power Supply Unit PSU 1 Power Supply Cable 13 Feet 1 inch 1 Communi...

Страница 15: ...1 Mounting Rack for RU wall mounting 1 Masonry Bolt set M8x80 for RU concrete wall mounting 4 Masonry Bolt set M8x80 for RU PSU concrete wall mounting 2 Nuts M10x25 Spring Washers 10 Plain Washers 10...

Страница 16: ...t involving installation operation or maintenance must be free from danger as far as reasonably possible Where there is a risk of damage to electrical systems involving adverse weather extreme tempera...

Страница 17: ...c sources such as large electrical equipment Environmental Humidity has an adverse effect on the reliability of the equipment It is recommended to install the equipment in locations having stable temp...

Страница 18: ...thin reach of the power cord and the power source has sufficient capacity Where appropriate ensure unused RF connectors are terminated Where appropriate ensure unused optical fiber connectors are prot...

Страница 19: ...items from packing materials until installation 3 3 2TOOLS See Appendix A for a full list of tools required for installation and maintenance 3 3 3PREPARATION Optical Fiber Fiber optic cables require p...

Страница 20: ...mFlex Master Unit Step 1 RF Unit installation Remove RFU slot cover plate on Chassis insert RFU and fasten the screws Each Unit can be installed in any one of eight RFU slots Power Supply Unit Fiber O...

Страница 21: ...tep 2 FOU installation Remove FOU slot cover plate on Chassis insert FOU and fasten the screws Each Unit can be installed in either one of two FOU slots Figure 8 FOU Installation Step 3 PSU installati...

Страница 22: ...stallated on the rear panel with four screws Connect DC 28V power cable to the EXT_PSU connector of the rack shown as below figure and the grounding wire must conncet to the rack grounding connector F...

Страница 23: ...to the modem abutment before installation Access the optional modem unit into the slot on the rear panel and screw Connect MODEM connector with MODEM connector of the rack with communication cable in...

Страница 24: ...ANUAL FOR COMFLEX 4500 5W ENU STATUS 1 0 0 Copyright refer to title page Page 24 Figure 14 Mounting Rack Figure 15 Angle Iron Installation Step2 Slide the MU on to the angle brackets and confirm it is...

Страница 25: ...FLEX 4500 5W ENU STATUS 1 0 0 Copyright refer to title page Page 25 Figure 16 MU Installation Step 3 Attach the MU onto the rack with the recommended rack screws Figure 17 Secure the Enclosure Step 4...

Страница 26: ...he following criteria General surroundings If mounting on dry wall 0 75 In min plywood backboard is required to support the weight of the equipment Ventilated and easy to reach area for maintenance an...

Страница 27: ...Wall Drilling Dimensions of RU Unit inch Step 3 Attach the mounting rack on a wall If a concrete wal use the 4 M10 110 masonry bolts Two M8x80 Masonry bolts Figure 20 Install Mounting Rack on the Wal...

Страница 28: ...Figure 21 Hang RU onto the Mounting Rack Step 5 Tighten the RU on masonry bolts with four M8 80 nuts Figure 22 Tighten the Screws at the Bottom of RU Step 6 Check the RU installated tightly and the he...

Страница 29: ...7 Remote PSU Installation Remote PSU should be installed afer RU finish installation It can be installed on the RU or on the wall nearby RU Installed on RU Remote PSU should be installed on the right...

Страница 30: ...0 Installed on the wall Step 1 Measure and mark two holes on the wall nearby RU the max demision from RU is 0 5m 14 96 4 37 Figure 25 Mounting Rack Installation Unit inch Step 2 Screw two hexagonal ma...

Страница 31: ...Copyright refer to title page Page 31 3 4 EQUIPMENT CONNECTORS The figures below present the connectors of ComFlex MU 1 2 3 4 5 6 7 8 Figure 27 MU Front Panel Connectors 13 12 11 10 9 14 15 16 17 18 1...

Страница 32: ...n connector 8 Digital display tube See chapter 4 for the detailed description 9 Grounding connector for redundant PSU 10 FOU Expansion FOU communication connector 11 POI POI communication connector 12...

Страница 33: ...cal fiber access port EXT_ALM External alarm port It provides an alarm report interface for other devices to report their alarms to CMS RS 485 For communication of expansion device LAN For local monit...

Страница 34: ...ied copper wire GND cable to RU Grounding point and connect the other side of the supplied copper wire GND cable to the building EARTH with two M6 10 screws Step 2 Connect one side of another supplied...

Страница 35: ...plex application connect the MU RFU TX RX port to the RF Source BTS or BDA For simplex application connect the MU RFU TX RX port to the RF Source downlink and then connect MU RFU RX port with RF Sourc...

Страница 36: ...a broadband antenna Step 3 Connect DC28V port of RU to DC28V port of remote PSU Step 4 Connect power cable on AC port with the public power grid 110 220VAC 6Amp maximum ANT PWR RUN ALM OP OP EXT_ALM R...

Страница 37: ...and definition Pin numbering are shown looking into the connector on the enclosure 1 2 3 4 Figure 36 Pins Allocation for EXT_ALM Port for RU Table 7 Pin Definition of EXT_ALM Port for RU Pin number 1...

Страница 38: ...the open terminal of the voltage free relay 2 BTS_COM Connects to the common terminal of the voltage free relay 3 BTS_CLOSE Connects to the close terminal of the voltage free relay 4 9 NC Reserved 3 5...

Страница 39: ...anel and RU bottorm panel each indicates the status of a particular function Table 9 MU LED Indications LED Indicator Normal Status Indication PWR Steady green Power indicator If LED is off it indicat...

Страница 40: ...ll show L when DL input powe is higher than 33 it will display H Figure 38 RFU Digital Display Table 11 RFU Digital Display Figure DL Input Power Level L 19dBm 19 33 19 33dBm H 33dBm 4 3 2 DIGITAL DIS...

Страница 41: ...FOR COMFLEX 4500 5W ENU STATUS 1 0 0 Copyright refer to title page Page 41 A b C d Figure 39 Optical Port No and Digital Display Table 12 FOU Digital Display Figure Optical Loss 0 9 0 9dBo H 9dBo End...

Страница 42: ...45 port with the supplied Ethernet cable to set up a physical connection Step 2 Go to laptop Control Panel Network and Internet Local Area Connection Right click it and click Properties Then click Obt...

Страница 43: ...R COMFLEX 5H00 1W2W ENU STATUS 1 0 0 Copyright refer to title page Page 43 Figure 42 Input IP Address Step 4 Input User Name admin Password default password admin Click Log in Figure 43 Input User Nam...

Страница 44: ...GUI Main Screen On Comba Web GUI Home page there are four Menu bars Devices Commissioning Firmware and Management 5 2 1 DEVICES The Devices page shows the actual connection diagram of MU and RU Figure...

Страница 45: ...Page 45 MU Main Management Screen Figure 46 MU Device Monitoring Unit Optical Unit Management Screen Figure 47 MU Device Optical Unit Note MU transmit optical power is 4 2dBm This part shows MU basic...

Страница 46: ...re connected by optical fiber RU device scanning is done Note Go to Commissioning page or Management page for device scanning Figure 49 RU Device NOTE There are three statuses for PA Service Normal Re...

Страница 47: ...ix times of PA Recovery PA Service status will be Shutdown which will need to be reset manually Reset at Management PA Reset Click on a specific band on the left side of RU Device page the correspondi...

Страница 48: ...sed to upgrade software and Swap is to replace current firmware version to the previous one Follow steps shown in below figure to upgrade firmware Figure 52 Firmware Screen Upgade Step 4 After clickin...

Страница 49: ...g reset Figure 54 Firmware Screen Pop up Window 2 Step 6 Clear browsing history and cookies from browser NOTE For MU software upgrade users need to re login Web GUI after reset is done Follow steps sh...

Страница 50: ...e 50 Figure 56 Firmware Screen Module upgrade 5 2 4 MANAGEMENT Other parameters can be configured on Management page Figure 57 Management Screen Click here to enter corresponding page Select device pa...

Страница 51: ...aremeter Device Parameter MU Alarm Enable RU Alarm Enable ATT value ATT value RF Switch RF Switch SNMP parameter Over temperature alarm threshold DL over output power threshold External Alarm level Im...

Страница 52: ...1 0 0 Copyright refer to title page Page 52 IP Setting Figure 59 Management IP Setting Note Here the device IP Address CANNOT be set as 192 168 8 SMS Setting Figure 60 Management SMS Setting Configur...

Страница 53: ...NUAL FOR COMFLEX 5H00 1W2W ENU STATUS 1 0 0 Copyright refer to title page Page 53 Maintenance Figure 61 Management Maintenance Security Figure 62 Management Security Click Modify Password window will...

Страница 54: ...e 63 Modify Password Note Username cannot be modified Device Reset Figure 64 Management Device Reset Note Device Reset process will last about 2 4 minutes For MU monitor reset users need to re login W...

Страница 55: ...PA will be turned off by software when PA output power or VSWR reflected power is exceed the threshold Users need to reset PA after debugging Device Info Figure 66 Management Device Info Note Users c...

Страница 56: ...1 of Commissioning Running scanning software will allocate an ID to RU so that MU can identify and visit it Device Remove Figure 68 Management Device Remove Note If the RU has been scanned and identif...

Страница 57: ...ER MANUAL FOR COMFLEX 5H00 1W2W ENU STATUS 1 0 0 Copyright refer to title page Page 57 Report Figure 69 Management Report License Figure 70 Management License Device frequency band authorization statu...

Страница 58: ...ement Alarm Log 5 3 COMMISSIONING PROCEDURE To complete the installation and commissioning users need to follow the steps below Step 1 Click Menu bar Commissioning on home page a work flow will show u...

Страница 59: ...1 0 0 Copyright refer to title page Page 59 Figure 73 Commissioning Procedure Device Scan Step 3 Click to enter to Params Setting page Click users can set the device information and system time Figur...

Страница 60: ...r time Step 4 Click to enter to the page to select folw to continue There are three flows to select Goto calibration flow Goto setup flow and Finish flow Figure 76 Flow to select NOTE1 Calibration is...

Страница 61: ...m before proceeding to step 5 Step 5 Select Goto calibration flow and click to enter to Calibratiion page after finishing Parems Setting Figure 77 Calibration screen Automatic calibration no need to s...

Страница 62: ...OMFLEX 5H00 1W2W ENU STATUS 1 0 0 Copyright refer to title page Page 62 Figure 78 Commissioning Procedure Automatic Calibration Figure 79 Commissioning Procedure Manual Calibration Select RU and frequ...

Страница 63: ...1 0 0 Copyright refer to title page Page 63 Figure 80 Commissioning Procedure Calibration Finish Step 6 Click to enter to MU Setup page after finishing Calibration Figure 81 Commissioning Procedure MU...

Страница 64: ...U unit RF Switch Set the RF switch status of this RF unit DL Input Power Input Power of the BTS signal access to this RF unit Note ComFlex system reaches its rated output power 30dBm when input power...

Страница 65: ...U Figure 84 RU Frequency Band Table Two parameters need to be set in this step RF Switch Set the RF switch status of Remote Unit Target DL Output Power Expected DL output power setting Note Rated outp...

Страница 66: ...and they have the same input power level each channel will reach it s rated power so the total output power will be input A gain inputB gain inputN gain For example if there are two 1900MHz bands ace...

Страница 67: ...e the same H L level with alarm level otherwise normal Alarm period 10s by default Over Temperature Alarm Alarm when equipment temperature is higher than the threshold otherwise normal Alarm judgment...

Страница 68: ...alarm Check device temperature on WEB GUI If device temperature e is over threshold make sure environment temperature is within the envireonment temperature range that RU supported 20 50 Apply climat...

Страница 69: ...1 APPENDIX A TOOLS FOR INSTALLATION AND MAINTENANCE The following tools not included in package are required for installation or routine maintenance Power Drill for wall mount Adjustable Wrench 0 31 i...

Страница 70: ...USER MANUAL FOR COMFLEX 5H00 1W2W ENU STATUS 1 0 0 Copyright refer to title page Page 70 7 2 APPENDIX B RMA RETURN MATERIAL AUTHORIZATION End of Section End of Document...

Страница 71: ...USER MANUAL FOR COMFLEX 5H00 1W2W ENU STATUS 1 0 0 Copyright refer to title page Page 71...

Отзывы: