background image

CSB200 Class B AIS 

R1.0 

 

                         3 

 

 

 

 

 
 
 
 
 

DISCLAIMER 

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND 
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED 
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL 
THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY 
DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR 
CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, 
PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF 
USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) 
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, 
WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING 
NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE 
USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY 
OF SUCH DAMAGE. 
 
 
This software uses components and source code developed by other 
companies or groups. 
 
Microsoft .Net Framework V2.0: 
 

Copyright © 2005 Microsoft Corporation 

 
ZedGraph Graphing component dll (http://zedgraph.org): 
 

Provided under the GNU Lesser General Public License 

 
 
 

 

All trademarks mentioned in this document are the property of their 
respective owners. 

CSB200 Class B AIS 

R1.0 

 

                         4 

 

 

 

 

PROGRAMMING THE CSB200 

proAIS Program 

Before the CSB200 can transmit it requires to be programmed with your 
own vessels information. This is done via the CSB200 field programmer 
proAIS 

 

Requirements 

The proAIS application is designed to operate with Microsoft Windows 
200, XP and above. Recommended minimum system requirements are: 

 Microsoft 

Windows 

XP 

SP2 

 

Display resolution of at least 1024 x 768 

 

At least one RS232 serial port (or USB to serial converter 
already installed*) 

*If you are using a USB to serial converter please ensure this is fully 
installed before proceeding. 

 

This software uses the Microsoft .Net Framework V2.0. The Framework 
will be automatically installed during setup if not already present on the 
system. 

Setup 

1.  Insert the installation CD and locate the Setup.exe file. 
2.  Double click the Setup.exe file to begin the installation.  
3.  Follow on screen prompts to install the .Net Framework if 

required 

4.  When the security warning below is displayed, select 'Install' 

 

Содержание CSB200

Страница 1: ... Manual CSB200 Class B AIS Transponder CSB200 Class B AIS R1 0 2 PROGRAMMING THE CSB200 4 PROAIS PROGRAM 4 STATIC DATA 7 GPS STATUS 10 DIAGNOSTICS 11 SERIAL DATA 14 OTHER VESSELS 15 SAFETY MESSAGES 16 COMMANDS 17 ...

Страница 2: ...tp zedgraph org Provided under the GNU Lesser General Public License All trademarks mentioned in this document are the property of their respective owners CSB200 Class B AIS R1 0 4 PROGRAMMING THE CSB200 proAIS Program Before the CSB200 can transmit it requires to be programmed with your own vessels information This is done via the CSB200 field programmer proAIS Requirements The proAIS application...

Страница 3: ... Connect 5 Once a connection is established the application is ready to use Connection status is indicated at the bottom left of the application window 6 The functions of proAIS are arranged in a series of tabs Each tab contains information relating to a particular aspect of the connected AIS transponder Depending on the version of proAIS installed not all tabs shown below may be visible Static da...

Страница 4: ...sh screen and version information Static Data This tab shows the current configuration of the AIS transponder and allows the configuration to be programmed during installation into a vessel CSB200 Class B AIS R1 0 8 When an un configured AIS transponder is connected for the first time the display will be similar to that shown below To configure the transponder all of the data fields must be comple...

Страница 5: ... Save static data to AIS button to programme this configuration into the AIS transponder A warning will be displayed asking you to verify the MMSI number Please check the number displayed is correct before proceeding If the number is incorrect click the No button to cancel programming of the MMSI CSB200 Class B AIS R1 0 10 Click the Yes button if the MMSI is correct The static data tab will be upd...

Страница 6: ...the green tick to appear If the red cross is still present after this time please refer to the active alarms section below The AIS will not transmit unless it has acquired GPS fix and has a valid MMSI programmed o AIS has received a position report has a red cross a position report from another vessel has been received If there is no other AIS equipped vessel in the area the red cross will remain ...

Страница 7: ...number of AIS messages received and transmitted on each of the AIS channels You can use this information to verify that the transponder is successfully receiving and transmitting data when other AIS equipped vessels are in range CSB200 Class B AIS R1 0 14 Serial Data This tab shows the raw NMEA 0183 serial data being output by the AIS A typical display is shown below Serial data can be logged to a...

Страница 8: ... with Class A AIS have the MMSI displayed in black text o Vessels equipped with Class B AIS have the MMSI displayed in blue text The name and call sign of each vessel is shown CSB200 Class B AIS R1 0 16 o Due to the way AIS operates this information may take some time to appear The speed in knots course in degrees decimal latitude and longitude are shown for each vessel The approximate distance to...

Страница 9: ...e Configure baud rates o Baud rates for the RS232 and RS422 NMEA 0183 communications ports can be set here The default value is 38400 should be used where possible The CSB200 Class B AIS R1 0 18 Update button should be clicked to send new settings to the AIS transponder Alarm output options By default the AIS transponder will output the status of all alarms every minute using AIALR sentences The u...

Страница 10: ...CSB200 Class B AIS R1 0 19 ...

Отзывы: