background image

9

Limited Warranty

Comar Electrical Services Ltd. warrants its power products against defects in material 
and workmanship for a period of one (1) year from date of purchase and extends this 
warranty to all purchasers or owners of the product during the warranty period.  Comar 
Electrical Services does not warrant its products against any and all defects: (1) Arising 
out of material or workmanship not provided or furnished by Comar Electrical Services 
Ltd. or (2) resulting from abnormal use of the product or use in violation of the 
instructions, or (3) in products repaired or serviced by other than Comar Electrical 
Services repair facilities, or (4) in components, parts or products expressly warranted by 
another manufacturer.  Comar Electrical Services agrees to supply all parts and labour or 
repair or replace defects covered by this warranty with parts or produc ts of original or 
improved design at its option, if the defective product is returned to any Comar Electrical 
Services authorized warranty repair facility or to the Comar Electrical Services factory in 
the original packaging, with all transportation costs and full insurance paid by the 
purchaser or owner. 

ALL REMEDIES AND THE MEASURE OF DAMAGES ARE LIMITED TO THE ABOVE.  
COMAR ELECTRICAL SERVICES SHALL IN NO EVENT BY LIABLE FOR 
CONSEQUENTIAL, INCIDENTAL, CONTINGENT OR SPECIAL DAMAGES, EVEN IF COMAR 
ELECTRICAL SERVICES HAS BEEN ADVISED OF THE POSSIBLITY OF SUCH DAMAGES.  
ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED ARISING BY LAW, COURSE 
OF DEALING, COURSE OF PERFORMANCE, USAGE OF TRADE, OR OTHERWISE, 
INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO A PERIOD OF (1) 
YEAR FROM THE DATE OF PURCHASE. 

SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY 
LASTS, OR THE EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE.  SO THE 
ABOVE LIMITATIONS MAY NOT APPLY TO YOU.  THIS WARRANTY GIVES YOU 
SPECIFIC LEGAL RIGHTS.  YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM 
STATE TO STATE. 

Содержание 50-120-240

Страница 1: ...ual Revision 1 08 NA Model No 50 120 240 60Hz 50 Amp AutoShore Comar Electrical Services Ltd 114 1515 Broadway Street Port Coquitlam BC Canada V3C 6M2 Tel 604 941 7646 Fax 604 941 7610 Email info comarelectric com ...

Страница 2: ...Table of Contents Pg 3 Pg 4 Pg 5 Pg 6 Pg 7 Pg 8 Important Safety Instructions Introduction Description of Operation Installation Specifications Performance Graphs Limited Warranty Pg 9 ...

Страница 3: ...Switching voltage selector switch to off does not completely isolate control wiring To do so disconnect shore cable at dock and switch main breaker off 5 Warning Install transformer in a well ventilated location Do not store materials particularly flammable material on or around transformer 6 No terminals or lugs are required for hook up of the AC wiring AC wiring should be no less than No 6 AWG c...

Страница 4: ...E unit you have the ability to automatically boost low dock voltage insuring the supply of usable voltage from virtually any dock The unit also provides protection from excessively high and excessively low dock voltage and provides isolation to combat electrolysis and reduce personal shock hazard ...

Страница 5: ...voltage has to drop to at least 262 volts before the unit can be reset by pushing the lit reset button on the front of the panel 4 For the unit to trip due to low voltage input shore voltage must be lower than 178 volts for 3 seconds The input shore voltage has to raise to at least 180 volts before the unit can be reset by pushing the lit reset button on the front of the control panel The unit wil...

Страница 6: ...ng diagram for proper installation Temp Sense Transformer Shore Receptacle Control Box Output to Ships Distribution Note A Circuit Breaker may be required between the Shore Receptacle and Control Box Consults local codes and regulations ...

Страница 7: ...W Transformer 18 x 12 x 18 W x D x H Transformer weight 267 pounds ABYC ISOLATION OF GALVANIC CURRENTS 8 20 1 A metallic shield shall be located between the primary and secondary windings and be electrically insulated from all other portions of the transformer It shall be designed to withstand without leakage a high potential test of 4000 volts 60 Hz for one minute applied between the shield and a...

Страница 8: ...8 Performance Graph ...

Страница 9: ...the defective product is returned to any Comar Electrical Services authorized warranty repair facility or to the Comar Electrical Services factory in the original packaging with all transportation costs and full insurance paid by the purchaser or owner ALL REMEDIES AND THE MEASURE OF DAMAGES ARE LIMITED TO THE ABOVE COMAR ELECTRICAL SERVICES SHALL IN NO EVENT BY LIABLE FOR CONSEQUENTIAL INCIDENTAL...

Отзывы: