Nokia Smart Home - умное решение для вашего дома. Скачайте бесплатное руководство пользователя для нашего продукта на нашем веб-сайте. Управляйте своим домом с легкостью и комфортом с помощью нашего умного устройства. manualshive.com.
2
3
• Read these instructions carefully before installation
• Must be installed by a trained and experienced technician
• Make sure you have turned off the power before doing
anything
Precautions
Страница 1: ...Smart heating solution Comap Smart Home Installation manual ...
Страница 2: ...2 3 Read these instructions carefully before installation Must be installed by a trained and experienced technician Make sure you have turned off the power before doing anything Precautions ...
Страница 3: ...module 1x gateway The thermostat is attached to the wall in a living area e g the living room The three devices communicate with each other via radio waves 868MHz The maximum distance between the gateway the module s and the thermostat depends on the structure of your home thickness of walls and building materials used and the radio environment presence of high voltage power lines overhead wires d...
Страница 4: ...it If the thermostat is no longer paired with the heating module contact Customer Service 1 2 3 ERROR CODES 1 Problem with pairing 2 Communication problem 3 Disconnection STARTING UP Welcome Heating command Stop command Room temperature Setpoint temperature Heating off Heating in progress LED display Heat indicator Activation zone Arrows OPERATION BUTTONS 19 5 You can activate the product by tappi...
Страница 5: ...at in a place where it cannot be exposed to direct sunlight If you have pets place the thermostat away from furniture they can sit on so that they are not detected by the presence detection sensor Recommended locations Connect the gateway to the modem using the two cables supplied Note If the modem does not have a USB port you can connect the gateway to the mains using a 5V DC USB charger minimum ...
Страница 6: ...ostat display 2 GAS OIL WOOD HEAT PUMP ELECTRIC ON OFF CONTACT Replacing a wired thermostat 12 Replacing a wireless thermostat or 1st installation 16 ELECTRICAL VERSION CONTROL WIRE 19 The following steps depend on the heating system Switch off the general power supply to the housing in order to avoid any risk of electrocution Switch off the power 3 ...
Страница 7: ...thermostats are connected to an input other than the one listed above eBus or EMS for example In this case identify the thermostat input TA LS LR or RT24 To install it open the protective cover of your water heater using the manual if necessary Find the terminal block of the room thermostat Connect terminals L phase and N neutral of the heating module to terminals L and N of the boiler or the term...
Страница 8: ... m max Note The current circuit of the potential free contact must be adjusted to the capacity of the radiators being controlled The required current for the control circuit must be less than 3A Attach the heating module holder 2 INSTALLATION OF THE CONTROL WIRE Installation on electric heating with centralised control wires Single zone ELECTRIC VERSION ...
Страница 9: ... electric heating with multiple control wires Single zone or multi zone Note for multi zones You can create up to 10 zones with one or more radiators in each zone To configure your zones go to My Account Configure Multi Zones once the installation is complete 1 2 Open the module by unclipping the back Open the heating module Then thread the wires through the hole in the holder Check the stripping ...
Страница 10: ...the dowels and screws Connect the three wires as shown In general the phase wire L is brown the neutral wire N is blue and the control wire FP is black The cross sectional area of the cables used for the power supply L N and the control wire must be adapted to the protection installed upstream Next steps p 23 Repeat the installation of the heating module for each radiator Screw the lid back on INS...
Страница 11: ...hermostat display which will automatically pair with the heating module E Activate the COMAP CSH thermostat If necessary you can perform a heating test by increasing the temperature using the arrow to the right a flame will appear on the thermostat display and the sensor will turn red indicating a heating command The heating light in the centre of the heating module must then light up Afterwards d...
Страница 12: ...Remove the thermostat holder by unclipping it 2 Fix the holder to the wall using screws and dowels Recommended location p 22 3 Place the thermostat on the holder by clicking it into place CONGRATULATIONS YOUR INSTALLATION IS COMPLETE ...
Страница 13: ... breaker with an output of max 2 A Contamination level 2 Nominal pulse voltage 2500V Automatic action type 1 Maximum current of the dry contact 3A Required material Modem with one RJ45 port and one free USB port Without a USB port a USB charger is required not included SPECIFICATIONS Dimensions Thermostat 110x110x25mm Heating module 110x110x25mm Gateway 82x82x23mm Design Design 5 5 Design Studio L...
Страница 14: ...FAQ http support comapsmarthome com Email contact comapsmarthome com Please do not hesitate to contact us our staff will be happy to help you ...