ID-FLX Lite Global Guide
67
Input
Analog input
CU: AI1-AI9
AIO: AI1-AI4
Binary input
Binary input
LoadRequest2
LoadRegDisable
(optional)
Binary input
Binary input
RegRequest2
R Reg Disable
(optional)
Output
Analog output
Analog output
Load Limit
ByRPMCtrlAout
(plug-in module)
Setpoints
Load limit
Load Input = Load
Load Bias
Load Request 1
Load Request 2
Load ReqRamp
Load UpLimit
Load DownLimit
Load Gain
Load Integral
Regulator
Reg Input
Reg Bias
Request
Request 2
Reg Gain
Reg Integral
Engine load limitation with analog output
Purpose: Protect the engine against overload by reducing the load.
Description: The engine load (e.g. feeder speed) is reduced when actual “Percentual load” (coming from ECU) is
over the
(or
) setpoint. Load can be continuously