P
P
a
a
g
g
e
e
1
1
2
2
o
o
f
f
3
3
8
8
I
I
N
N
S
S
T
T
R
R
U
U
C
C
T
T
I
I
O
O
N
N
M
M
A
A
N
N
U
U
A
A
L
L
C
C
D
D
N
N
M
M
-
-
s
s
e
e
r
r
i
i
e
e
s
s
C
C
O
O
U
U
P
P
L
L
I
I
N
N
G
G
/
/
D
D
E
E
C
C
O
O
U
U
P
P
L
L
I
I
N
N
G
G
N
N
E
E
T
T
W
W
O
O
R
R
K
K
S
S
(
(
C
C
D
D
N
N
s
s
)
)
S
S
E
E
C
C
T
T
I
I
O
O
N
N
3
3
-
-
P
P
R
R
O
O
D
D
U
U
C
C
T
T
I
I
N
N
F
F
O
O
R
R
M
M
A
A
T
T
I
I
O
O
N
N
1
1
9
9
1
1
2
2
1
1
E
E
L
L
T
T
O
O
R
R
O
O
R
R
O
O
A
A
D
D
●
●
S
S
I
I
L
L
V
V
E
E
R
R
A
A
D
D
O
O
,
,
C
C
A
A
L
L
I
I
F
F
O
O
R
R
N
N
I
I
A
A
9
9
2
2
6
6
7
7
6
6
●
●
(
(
9
9
4
4
9
9
)
)
4
4
5
5
9
9
-
-
9
9
6
6
0
0
0
0
●
●
c
c
o
o
m
m
-
-
p
p
o
o
w
w
e
e
r
r
.
.
c
c
o
o
m
m
Rev072518
3
3
.
.
5
5
P
P
r
r
o
o
d
d
u
u
c
c
t
t
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
T
T
a
a
b
b
l
l
e
e
1
1
-
-
P
P
r
r
o
o
d
d
u
u
c
c
t
t
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
CDN M125E
CDN M225E
CDN M325E
CDN M425E
CDN M525E
CDNM250E
CDN M350E
CDN M450E
CDN M1100
CDN M2100
GENERAL
Product Description
Power Line Coupling/Decoupling Networks (CDNs)
Application
Power Line Conducted Immunity Tests
Standards
IEC 61000-4-6, CISPR 16-1-2
Number of Power Line Conductors
1
2
3
4
5
2
3
4
1
2
Common Mode Adapters
(2 each)
CDN ADA-
M125E
CDN ADA-
M225E
CDN ADA-
M325E
CDN ADA-
M425E
CDN ADA-
M525E
CDN ADA-
M250E
CDN ADA-
M350E
CDN ADA-
M450E
CDN ADA-
M1100E
CDN ADA-
M2100E
Frequency Range
150 kHz to 230 MHz
Common Mode
Impedance
150 kHz to 24 MHz
150Ω
(±20Ω)
24 MHz to 80 MHz
150Ω
(-45Ω / +60Ω)
80 MHz to 230 MHz
150Ω
(±60Ω)
Decoupling
Attenuation
(Isolation) *
150 kHz to 1.5 MHz
15-50 dB
25-55 dB
50 dB
50 dB
50 dB
25-55 dB
40 dB
40 dB
20-45 dB
20-45 dB
1.5 MHz to 230 MHz
50-20 dB
55-15 dB
50-20 dB
50-10 dB
50-5 dB
55-15 dB
40-20 dB
40-10 dB
45-20 dB
45-20 dB
* slopes increase/decrease linearly with the logarithm of frequency
Voltage Division
Factor
9.5 dB
150 kHz to 10 MHz
(-0.5/+1 dB)
(-0.5/+1 dB)
(-0.5/+1 dB) (-0.5/+1.5 dB) (-0.5/+1.5 dB) (-0.5/+1 dB) (-0.5/+1.5 dB) (-0.5/+1.5 dB) (-0.5/+1 dB)
(-0.5/+1 dB)
10 MHz to 230 MHz
(-0.5/+1.5 dB) (-0.5/+3 dB) (-0.5/+2.5 dB) (-0.5/+2.5 dB) (-0.5/+3.5 dB) (-0.5/+4 dB)
(-0.5/+5 dB) (-0.5/+3.5 dB) (-0.5/+1 dB) (-0.5/+2.5 dB)
ELECTRICAL
Current
(maximum continuous, per line)
25 Amperes
50 Amperes
100 Amperes
Voltage
(maximum)
250 Volts AC, 350 Volts DC
(line to ground)
RF Voltage
(maximum)
40 Volts
rms
INPUT/OUTPUT CONNECTORS
EUT/AE Power Ports
4 mm shrouded banana sockets
5.2 mm banana socket
with shrouded sheath
Multi-Contact
ID/S6AR-N-B4S
RF Port
50Ω - BNC-Type
(female)
DIMENSIONS AND WEIGHT
Figure 2 - Dimension
(A)
282 mm
355 mm
370 mm
392 mm
465 mm
Figure 2 - Dimension
(B)
332 mm
413 mm
428 mm
450 mm
525 mm
Figure 2 - Dimension
(C)
155 mm
179 mm
Figure 2 - Dimension
(D)
155 mm
16.8 mm
Figure 2 - Dimension
(E)
166 mm
179 mm
Figure 2 - Dimension
(F)
30 mm
40 mm
Figure 2 - Dimension
(G)
100 mm
100 mm
Figure 2 - Dimension
(H)
100 mm
118 mm
Figure 2 - Dimension
(I)
75 mm
89 mm
82 mm
Weight
(lbs. / kg)
4.5 / 2
5.5 / 2.5
5.5 / 2.5
5.5 / 2.5
6 / 2.7
7 / 3.2
7.5 / 3.4
8 / 3.6
12.5 / 5.7
13 / 5.9
All values are typical, unless specified.
All specifications are subject to change without notice.
(A)
(C)
(H)
(I)
(B)
(E)
(F)
POWER LINE COUPLING/DECOUPLING NETWORK
150 kHz - 230 MHz
xxx AMPERES
www.com-power.com
CDN MxxxE
EUT PORT
EUT PORT
L
N
L1
L2
L3
L
N
PE
CDN ADA-MxxxE
SHORTING ADAPTER
www.com-power.com
(G)
(D)
F
F
i
i
g
g
u
u
r
r
e
e
2
2
-
-
P
P
r
r
o
o
d
d
u
u
c
c
t
t
D
D
i
i
m
m
e
e
n
n
s
s
i
i
o
o
n
n
s
s