Colzer CFT4.0D Скачать руководство пользователя страница 8

5

4. Plug in Electrical Cord

The dehumidifier needs to be plugged into a GFCI-protected 115 volt outlet rated for at
least 16 amps. Uncoil the power cord and plug it firmly into a suitable outlet.

Note:

When the dehumidifier is first plugged into AC power, the control panel display will

light up for a second, which is part of the dehumidifier’s self-diagnosis procedure and no
user intervention is required.

5. Understand the Control Panel

The control panel on the dehumidifier has an LCD screen and 4 buttons. Press the POWER
Button to turn the dehumidifier on. The LCD screen will light up and display the readouts.

(1) What is on the LCD Screen?
Big Font Digital Number

(

43

on the above illustration) is humidity reading. If no operations

on the control panel, this big font digital number is the humidity reading of the inlet air the
dehumidifier detects which is similar to the room humidity level. When you are pressing
the

or

button to set a desired humidity percentage value, the big font digital number

will turn to display the setting value and flash.

Small Font Digital Number

(

34

on the above illustration) is temperature reading of the

IMPORTANT

Please let the dehumidifier stand upright for

24 hours

before the first time plugging in.

The dehumidifiers may have been tilted or placed upside down during shipping. Leave the

dehumidifier to stand upright for 24 hours so the oil in the compressor can settle from the

move, not doing so can affect the performance or lifespan of the dehumidifier.

Содержание CFT4.0D

Страница 1: ...Colzer Dehumidifier User Manual Model No CFT4 0D Please read this User Manual before operating and keep safe for future reference...

Страница 2: ...n operation instructions troubleshooting maintenance tips and warranty information to ensure the reliability and longevity of your dehumidifier We also kindly ask you to take a few minutes to register...

Страница 3: ...rstand the Control Panel 5 1 What is on the LCD Screen 5 2 Understand the Control Buttons 7 6 General Operation Instructions 7 7 Timer Setting 7 8 Smart Functions 8 MAINTENANCE 10 1 Cleaning the Dehum...

Страница 4: ...ing flammable or dangerous materials Unplug the power supply before cleaning or storing the dehumidifier Always grasp the plug not the cord to unplug Do not put fingers or other items into air inlet o...

Страница 5: ...2 PARTS IDENTIFICATION 1 Handle 2 Air Inlet 3 Power Cord 4 Drain Outlet 5 Control Panel 6 Air Outlet 7 Wheel NOTE DO NOT OBSTRUCT THE AIR INLET OR OUTLET...

Страница 6: ...nd screws on both sides of the handle to take the handle off 2 Install the handle as illustrated below please note to align the holes on the handle with the holes on the dehumidifier 3 Tighten the 4 h...

Страница 7: ...to the drain outlet on the right side of the dehumidifier to drain the condensation water automatically by gravity NOTE You can use any other hoses with inner diameter of 5 8 0 63 inches instead Unwin...

Страница 8: ...Font Digital Number 43 on the above illustration is humidity reading If no operations on the control panel this big font digital number is the humidity reading of the inlet air the dehumidifier detect...

Страница 9: ...ally restart to dehumidify That is to say the dehumidifier will automatically stop or restart to maintain the room humidity level within a range of 3 of the set point For example if the set humidity i...

Страница 10: ...registered automatically after 5 seconds of no operations on the control panel Note The dehumidifier with a humidistat will stop and start automatically to maintain the inlet humidity level the user h...

Страница 11: ...g be registered automatically after 5 seconds of no operations on the control panel 4 The small font readout will count down the time remaining 8 7 6 etc until the dehumidifier either starts or stops...

Страница 12: ...is defrosting you can see the DEFROSTING icon light up on the LCD screen 3 Auto Restart If the dehumidifier shuts off unexpectedly due to power outage the dehumidifier will restart with the previous...

Страница 13: ...Cleaning the Air Filter The working performance of the dehumidifier will be greatly reduced if the filters become blocked The air filter should be cleaned approximately every 2 weeks and may require...

Страница 14: ...nstall the filter NOTE DO NOT operate the dehumidifier without a filter because dirt and lint will clog it reducing performance 3 When Not Using dehumidifier for Long Periods of Time Wait for 1 day af...

Страница 15: ...ressure Fault E8 Compressor Current Overload Fault E9 Fan Current Overload Fault E7 The water bucket of the pump is full Ec Display Fault You are unable to control the dehumidifier via the control pan...

Страница 16: ...r code displays Contact customer service Dehumidifier collects little water Insufficient working time Allow more working time Filter is blocked Clean filter Air Inlet or Outlet is blocked Clear the ob...

Страница 17: ...the proven defective product through repair or replacement of any defective part and necessary labor so that it conforms to its original specifications A replacement product may be provided instead of...

Отзывы: