The TIMER function enables you to either Delay AUTO-ON or Delay AUTO-OFF the
dehumidifier in the choice from 1 hour to 24 hours.

· Setting an AUTO-ON timer:

When the dehumidifier is off,

selecting Timer will turn the

dehumidifier on in the hours that will be set.

· Setting an AUTO-OFF timer:

When

the dehumidifier is on, selecting Timer will turn the

dehumidifier off in the hours that will be set.

Follow the below steps to set the TIMER:

1) Press and hold the Timing/Function Button for about 3 seconds, until you see the icon
TIMER icon lights up and flashes and the small font digital number turns to display as 00 H;
2) Adjust the timer setting by pressing

or

button repeatedly to change the delay

timer at 1-hour increments, up to 24 hours.
3) After selected the target timer value, press Timing/Function Button to confirm your
setting, or let the setting be registered automatically after 5 seconds of no operations on
the control panel.
4) The small font readout will count down the time remaining (8,7,6, etc.) until the
dehumidifier either starts or stops.
5) To disable the timer function, manually turn ON/OFF the dehumidifier, or set the timer
to 00.

Note:
·

Before entering the AUTO ON TIMER setting, make sure power is being supplied to the

dehumidifier.

·

For the AUTO ON setting, please turn on the dehumidifier to select a desired humidity

level. Otherwise, the humidity maintained will be the same as the previous setting.

·

You can only set AUTO ON timer when the dehumidifier is off or set AUTO OFF timer when

the dehumidifier is on, but not be able to set both AUTO ON and AUTO OFF timer at the
same time.

·

The TIMER feature is one-shot. So the TIMER will ONLY function one time instead of

cycling the dehumidifier on or off indefinitely.

·

The TIMER function will be disabled when the dehumidifier has been powered on/off

manually.

·

Set the timer as 00, the timer function will not be activated.

8. Smart Functions

Содержание CFT4.0D

Страница 1: ...Colzer Dehumidifier User Manual Model No CFT4 0D Please read this User Manual before operating and keep safe for future reference...

Страница 2: ...n operation instructions troubleshooting maintenance tips and warranty information to ensure the reliability and longevity of your dehumidifier We also kindly ask you to take a few minutes to register...

Страница 3: ...rstand the Control Panel 5 1 What is on the LCD Screen 5 2 Understand the Control Buttons 7 6 General Operation Instructions 7 7 Timer Setting 7 8 Smart Functions 8 MAINTENANCE 10 1 Cleaning the Dehum...

Страница 4: ...ing flammable or dangerous materials Unplug the power supply before cleaning or storing the dehumidifier Always grasp the plug not the cord to unplug Do not put fingers or other items into air inlet o...

Страница 5: ...2 PARTS IDENTIFICATION 1 Handle 2 Air Inlet 3 Power Cord 4 Drain Outlet 5 Control Panel 6 Air Outlet 7 Wheel NOTE DO NOT OBSTRUCT THE AIR INLET OR OUTLET...

Страница 6: ...nd screws on both sides of the handle to take the handle off 2 Install the handle as illustrated below please note to align the holes on the handle with the holes on the dehumidifier 3 Tighten the 4 h...

Страница 7: ...to the drain outlet on the right side of the dehumidifier to drain the condensation water automatically by gravity NOTE You can use any other hoses with inner diameter of 5 8 0 63 inches instead Unwin...

Страница 8: ...Font Digital Number 43 on the above illustration is humidity reading If no operations on the control panel this big font digital number is the humidity reading of the inlet air the dehumidifier detect...

Страница 9: ...ally restart to dehumidify That is to say the dehumidifier will automatically stop or restart to maintain the room humidity level within a range of 3 of the set point For example if the set humidity i...

Страница 10: ...registered automatically after 5 seconds of no operations on the control panel Note The dehumidifier with a humidistat will stop and start automatically to maintain the inlet humidity level the user h...

Страница 11: ...g be registered automatically after 5 seconds of no operations on the control panel 4 The small font readout will count down the time remaining 8 7 6 etc until the dehumidifier either starts or stops...

Страница 12: ...is defrosting you can see the DEFROSTING icon light up on the LCD screen 3 Auto Restart If the dehumidifier shuts off unexpectedly due to power outage the dehumidifier will restart with the previous...

Страница 13: ...Cleaning the Air Filter The working performance of the dehumidifier will be greatly reduced if the filters become blocked The air filter should be cleaned approximately every 2 weeks and may require...

Страница 14: ...nstall the filter NOTE DO NOT operate the dehumidifier without a filter because dirt and lint will clog it reducing performance 3 When Not Using dehumidifier for Long Periods of Time Wait for 1 day af...

Страница 15: ...ressure Fault E8 Compressor Current Overload Fault E9 Fan Current Overload Fault E7 The water bucket of the pump is full Ec Display Fault You are unable to control the dehumidifier via the control pan...

Страница 16: ...r code displays Contact customer service Dehumidifier collects little water Insufficient working time Allow more working time Filter is blocked Clean filter Air Inlet or Outlet is blocked Clear the ob...

Страница 17: ...the proven defective product through repair or replacement of any defective part and necessary labor so that it conforms to its original specifications A replacement product may be provided instead of...

Отзывы: