.75” GHT Female

(19.05mm)

Remove rubber end piece to

expose .75” threaded male 

hose for attaching accessories.

.75” GHT female inlet

N2F48

A

B

1

2

3

6

7

4

4

5

5

4

1622 Browning   Irvine, CA   92606-4809   Phone: 949.474.0777   Toll Free: 800.626.2117   Fax: 949.474.1191   www.columbiasinks.com   email: [email protected]

©2013 Columbia Products

INDUSTRIAL SPRAY FOAMER/SANITIZER 

COLUMBIA SPECIFICATIONS     MODEL N2F48

Trouble Shooting Guide

Problem

Possible Cause

Remedy

1.  Unit does not draw a 

concentrate

a. Clogged suction tube strainer

b. Metering tip orifice obstructed

c. Water pressure too low

d. Mineral deposits in barrel of foamer

e. Clogged water inlet

a. Clean or replace

b. Rinse tip or replace: Do not attempt to clean as it may alter size of orifice

c. Minimum 25 PSI required

d.  Back flush unit. Remove container, suction in tube and metering tip. Put finger over barrel 

opening. Apply minimal water pressure through garden hose at nozzle of barrel to be 

flushed. Descale foamer by soaking in weak descaling solution.

e.  Clean or replace strainer. strainer (low water flow)

2. Weak foaming action

a. Clogged water inlet strainer

b. Water pressure too low

c. Water temperature too high

a. Clean or replace

b. Minimum 25 PSI required

c.  Use lower temp water source. (Concentrate flow decreases above 140º F water)

If above steps fail to produce good concentrate draw and/or foaming action, replace lid assembly. See component chart previous page.

Replacement Parts

 

Part No.

 

Decription

1  

N2 

Insulated Water Nozzle

2  

N2FC Coupler

A  

N2F48L  Replacement Foamer Lid kit

 

3  

Foamer Lid

 

4  

Suction Tube (6”)

 

5  

Foot Strainer

B  

N2FS4L  Replacement Sanitizer Lid Kit

 

6  

Sanitizer Lid

 

4  

Suction Tube (6”)

 

5  

Foot Strainer

7

  N2FM 

Meetering Tips (15 qty.) 

Model N2F48L – Foamer Lid

Model N2FS4L – Sanitizer Lid