18|EN
TECHNICAL DATA
Power supply
230V 50Hz
Power consumption
1000W
EER cooling medium
2,63
Cooling medium
R410A
Noise level
62dB(A)
Maximum allowed overpressure during operation:
the suction and pumping part of the cooling system
1,0MPa/3,5MPa
A/C unit dimensions (L x W x H)
41 x 33 x 79 cm
Package dimensions (L x W x H)
49,4 x 39,4 x 88 cm
Nettto weight
25 kg
Working temperature cooling mode
17-30
o
C
Recommended room area
~ 15 m
2
TROUBLE SHOOTING
Before contacting professional service, check it first yourself referring to the followings
Problem
Cause
Solution
The air conditioner does
not function.
No power supply.
Connect to power supply
outlet and switch on
“FL” flashes on the display
screen
Drain water
Timer-off is running.
You can turn on the unit
three minutes later..
The air conditioner
restart frequently
In direct sunlight
Close curtains.
Windows or doors open,
many people or a heat
source in the room.
Close doors and windows,
remove the heat source
Dirty filter
Clean or replace the
filter(s).
Air inlet or air outlet
blocked
Remove the blockage
The unit is too noisy
Unit stands uneven.
Place on an even, solid
surface (less vibration).
No work of compressor.
Self protect of compressor
Wait for 3 minute and
restart again after the
descend of temperature
Cautions: Switch off the unit and unplug it immediately if anything abnormal
happens. Then contact a qualified electrician.
Above data without advance notice for product improvement
Содержание KLC9000
Страница 2: ......
Страница 35: ...RU 35 1 2 3 8 8 4 5 6 7...
Страница 36: ...36 RU 8 9 10 11 12 13 14 15 16 17 50...
Страница 37: ...RU 37 KLC9000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C A B C ON OFF...
Страница 38: ...38 RU 50 B a 10 B C C A A 1500 x...
Страница 42: ...42 RU FL 3...
Страница 67: ...PL 67...
Страница 68: ...PL 68...