Problem
Cause
Solution
The air conditioner does not
function.
No power supply.
Connect to power supply outlet
and switch on
flashes on the display screen
Drain water
The air conditioner restart
frequently
In direct sunlight
Close curtains.
Windows or doors open, many
people or a heat source in the
room.
Close doors and windows, remove
the heat source
Dirty filter
Clean or replace the filter(s).
Air inlet or air outlet blocked
Remove the blockage
The unit is too noisy
Unit stands uneven.
Place on an even, solid surface
(less vibration).
No work of compressor.
Self protect of compressor
Wait for 3 minute and restart
again after the descend of
temperature
Cautions: Switch off the unit and unplug it immediately if anything abnormal happens.
Then contact a qualified electrician.
Above data without advance notice for product improvement
TECHNICAL DATA
Power supply
220-240V~ 50Hz
Cooling medium
R290/130g
Cooling efficiency
7000Btu(2.06KW)
Power consumption
792W
Maximum allowed overpressure
suction
0.6MPa
pumping
1.8MPa
Maksymalne dopuszczalne ciśnienie
3.0MPa
Air flow
300m³/h
Fuse parameters of the machine
Type:
5ET or SMT
Voltage:
250V
Current:
3.15 A
Addendum
Schematic diagram of the air-conditioning system (Refer to the nameplate on the product
for the detailed technical parameters)