Ci Instruction Manual

 

Page 17 of 20

 

 

3. 

RUNNING UTILITIES 

 

 

1.  Open the Ci Utilities program by 

double clicking on the icon on the 
desktop or start menu. 

 

2.  Right click in any part of 

the opening screen, and 
enter the password “pass” 
for the advanced utilities 
functions. 

 

NOTE: This is for engineers 
only and must not be given to 
end-users unless absolutely 
necessary. 

 

 

3.  The Ethernet Setup tab 

holds the IP address and 
port details for scanning 
over the network. 

 
The IT department needs to 
issue the IP address. The 
Command and Data ports may 
need changing to 17236 
(Command) and 17237 (Data) 
or to ones issued by the IT 
department. 

 

 

Содержание SmartLF Ci 40E

Страница 1: ...nfidential controlled document and is the property of Colortrac Ltd It is not to be copied or reproduced in part or whole S Sm ma ar rt tL LF F C Ci i S Sc ca an nn ne er rs s P P0 00 03 31 10 00 0 M...

Страница 2: ...quality observations should be reported to Technical Support Colortrac Ltd Colortrac Ltd shall not be liable for any damages errors issues or events that result from the use of the equipment or this m...

Страница 3: ...Ci Instruction Manual Page 3 of 20 11 Contents 1 REPLACING MAIN BOARD 4 2 CONFIGURING MAIN BOARD TO A Ci24 16 3 RUNNING UTILITIES 17 4 NORMALISATION 19 5 AUTO STITCH 20...

Страница 4: ...ng any panels power up the scanner and run the utilities program and make a note of the motor speed as in Chapter 3 Running Utilities NOTE If the board is faulty so you can not run the utilities or th...

Страница 5: ...ight Sub A away from the chassis 5 Remove the 4 x M3 pan head screws from the PCB Tray covering the Main Board NOTE The bottom right hand corner screw acts as an earth point 6 Disconnect the Ethernet...

Страница 6: ...cover with suppressors the wires are hard soldered on and can be easily broken off and so great care is needed when handling this cable A soldering iron is required to change the suppressors so it is...

Страница 7: ...0 10 Disconnect the mains plug from the Main Board and remove the PCB Tray For Ci24 11 For the Ci24 PCB Tray remove the 4 x M3 screws in each corner 12 Pull the PCB tray out gently remembering the pow...

Страница 8: ...Ci Instruction Manual Page 8 of 20 13 Disconnect the inline connector for the power cable 14 Disconnect the Power cable from the main board 15 Disconnect all the remaining cables from the Main Board...

Страница 9: ...reaking the locking plates so care is required 17 Remove the 4 x M3 Pan Head Screw holding the Main Board in place 18 Lift the board away from the scanner and remove the CIS cables by pulling them awa...

Страница 10: ...damage the cables during insertion Make sure the cable fits completely into the connector so that little or no silver is showing 21 Close the locking plates to secure the cable and prevent it being pu...

Страница 11: ...nnector onto the main board making sure it latches in place 25 While refitting the PCB Tray make sure that all the fitted cables are out of the way of any edges of the cover Feed the large ribbon cabl...

Страница 12: ...4 x M3 pan head screw to hold the cover on remembering to fit the earth lead to the bottom right hand screw 27 Reconnect the mains cable together making sure the latch locks in place 28 Reconnect the...

Страница 13: ...Cable Tray Right Sub A making sure the left hand end is fed on first Make sure the ribbon cable is not caught on the metal tray when fitting 31 Refit the 6 x M3 pan head screw to hold the Cable Tray R...

Страница 14: ...age 14 of 20 Ci24 32 To refit the PCB Tray reconnect the power cable into the main board 33 Reconnect the inline power cable connector 34 Reposition the PCB Tray making sure that none of the cables ar...

Страница 15: ...canner go to the Set Parameters program as described in chapter 2 Configuring Main Board and configure the main board to the scanner model Reset Flash Ci40 or Reset Flash Ci24 depending on scanner typ...

Страница 16: ...rogram from the Ci page www colortracsupport com login details if un known available on request from support 2 The program installs on the PC and can be located in the C Program Files Colotrac SetCiPa...

Страница 17: ...the password pass for the advanced utilities functions NOTE This is for engineers only and must not be given to end users unless absolutely necessary 3 The Ethernet Setup tab holds the IP address and...

Страница 18: ...is the stitch layout for the Ci24 with 3 CIS 7 Firmware Installation will allow the firmware to be updated The firmware can be downloaded from the website or sent via email and stored on the PC conne...

Страница 19: ...sation sheet with the black end inserted first face upwards NOTE If target is only white insert matt side up 3 Click Full Normalisation This process takes approx 1 5 minutes Make sure the process is c...

Страница 20: ...titch target with the 2 x horizontal lines inserted first face up 3 Click Auto Stitch This process takes a few minutes Make sure the process is complete before shutting anything down or scanning 4 For...

Отзывы: