ColleBuilt Products SD-70 Скачать руководство пользователя страница 4

 

 

 

Testing Function  

1.

  After installing all of the necessary components it is time to test the function of 

the system.  

2.

  With the key off check that both the main and the auxiliary battery have proper 

voltage.   

3.

  Start the car and watch the led indicator on the charging isolator. After a short 

delay the charging isolator led will turn on indicating that it is allowing alternator 
current to flow to the auxiliary battery. Check this by using a voltage meter to 
verify auxiliary battery voltage. Turn the engine off and place the key in the 
ignition position without starting the vehicle. Wait one minute and ensure that the 
led on the charging isolator is off. If this is the case then the charging isolator is 
working correctly and it is now time to check override switch function. 

4.

   Allow any surface charge to dissipate and using a voltmeter measure the voltage 

of each battery and record the results.  

5.

  With the key in the off position, turn on the vehicles lights manually and using a 

volt meter monitor the main battery’s voltage. It should drop steadily as the load 
from the light circuit slowly drains power from the main battery. Now monitor the 
auxiliary battery voltage. It should stay constant at the previously recorded 
voltage and should not drop while the lights are on.  

6.

  With the key still in the off position, activate the override switch inside the vehicle. 

At this time the indicator led on the switch should be on. Turn on the vehicles 
lights again and check the auxiliary battery’s voltage. It should now be falling at 
the same rate as the main battery. If the system does not behave as expected 
please contact us for additional assistance.  

 

 

 

 
 
 
 
 
 

Содержание SD-70

Страница 1: ...rovided with the products and install them following all guidelines Follow the maintenance guidelines as instructed in the installation instructions as well as this notification form If a back up system is not properly installed into the modified vehicle and maintenance guidelines are not met it could result in serious injury and or death INSTALLATION GUIDELINES 1 Failure to follow these guideline...

Страница 2: ...battery All ground connections should be made directly to the vehicles negative battery post on the main battery All 12V connections should be tied directly to the vehicles positive battery post on the main battery All wiring for the solenoid and charging isolator 12V connections should be equivalent size gauge to the factory main battery wire or 4 gauge wire whichever is larger Also the chassis g...

Страница 3: ...ive battery post on auxiliary battery 16G Out to empty small terminal on solenoid opposite of the ground connection Blue Red Brown Orange 16G Chassis Ground Switch Wiring Solenoid 16G ground wire 4G Wire Minimum 4G Wire Minimum 4G Wire Minimum 4G Wire Minimum 5A Fuse within 18 Of Battery ...

Страница 4: ...and it is now time to check override switch function 4 Allow any surface charge to dissipate and using a voltmeter measure the voltage of each battery and record the results 5 With the key in the off position turn on the vehicles lights manually and using a volt meter monitor the main battery s voltage It should drop steadily as the load from the light circuit slowly drains power from the main bat...

Отзывы: