035-17468-001 Rev. A (801)
Unitary Products Group
5
FIGURE 1 :
Dimensions - Upflow models
20
6-3/8
1-1/4
2-3/4
6-1/8
B
A
28-1/2
6-7/8
9-7/8
20-5/8
1-3/4
14-1/2
22-3/4
B
20
D
INTAKE
CONNECTION
FRONT
TOP IMAGE
E
VENT CONNECTION
(vent size)
BOTTOM IMAGE
FRONT
3/4”
FLANGE
A
C
28-1/2
23
WITH K.O.
REMOVED
MODELS
P*XU -V & G9V-UH
A
B
C
D
E
60 / 55 / 1200 /”B”
80 / 75 / 1600 /”C”
100 / 95 / 2000 /”C”
120 / 112 / 2000 /”D”
17-1/2
21
21
24-1/2
16-1/4
19-3/4
19-3/4
23-1/4
13-1/8
16-5/8
16-5/8
20-1/8
2
2
2
3
2
2
2
2
1
1. Vent pipe must be increased to 3” on this unit.
OPTIONAL SIDE RETURN
CUT-OUT (EITHER SIDE)
CONDENSATE
DRAIN
T’STAT
WIRING
7/8” K.G.
3/4
6
1-3/4
4-1/8
3-1/8
8-7/8
45
Table 1:
RATINGS & PHYSICAL / ELECTRICAL DATA - UPFLOW MODELS
P*XU-V/G9V—UH
AFUE1
LOW
FIRE
TEMP.
RISE °F
HIGH
FIRE
TEMP.
RISE °F
MAX.
OUTLET
AIR
TEMP. °F
BLOWER
TOTAL
UNIT
AMPS
MAX.
OVER-CURRENT
PROTECT2
MIN WIRE SIZE
(AWG) @ 75 FT.
ONE WAY2
INPU
MBH
H/L
OUTPUT
MBH
H/L
NOM.
CFM
HP
AMPS
SIZE
60/39
55/36
1200
93.5
45 - 75
45 - 75
175
1/2
1.7
11x8
9.6
20
14
80/52
75/48
1600
93.5
30 - 60
30 - 60
165
3/4
3.6
11x8
12.0
20
14
100/65
95/60
2000
94.0
30 - 60
30 - 60
160
1
4.3
11x10
14.5
20
12
120/78
112/72
2000
94.0
45 - 75
45 - 75
175
1
4.4
11x10
14.5
20
12
1.
AFUE numbers are determined in accordance with DOE test procedures
2.
Wire size and overcurrent protection must comply with the National Electrical Code (NFPA-70-latest edition).
·
For altitudes above 2,000 ft., reduce capacity 4% for each 1,000 ft. above sea level. Refer to instructions 035-14460-000.
·
Wire size based on copper conductors, 60°C, 3% voltage drop.
·
Continuous return air temperature must not be below 55°F.