background image

TOOLS  REQUIRED:  

7/16”, 1/2”, 9/16", and 5/8” sockets and

ratchets, block(s) of wood (minimum of 6” tall).

Refer to the parts list on page 9.

WHEEL INSTALLATION

1. Block up end of generator opposite the fuel tank cap to 

install wheel kit.

2. Slide the axle 

(item 35)

through the wheel brackets on the 

carrier, then through a wheel 

(item 31)

, with the offset side 

of the wheel hub against the wheel bracket.

3.

Secure the wheel to the axle with the axle cap 

(item 16)

tapping the cap onto the axle with a hammer.

4. Repeat above instructions for the remaining wheel.

FOOT INSTALLATION

1. Blocking up the engine side of the generator, place the 

foot bracket 

(item 27)

under the carrier channel.  Thread a 

5/16-18 x 4” bolt 

(item 29)

with a rubber foot 

(item 32)

through the mounting holes and thread a 5/16 flange nut 

(item 15)

to the bolt to secure the foot bracket to the carrier.

Caution: Do not over tighten so that the rubber foot 
material collapses.

HANDLE INSTALLATION

1. Place handle

(item 28)

over carrier tubing on same end as 

feet, centering handle on the carrier.

2. Slide 7/16 x 2” bolt

(item 30)

through handle as shown in 

diagram and secure with 7/16” nyloc nut

(item 33).  

Tighten 

until handle is securely clamped to the carrier tubing.

3. Apply aerosol hairspray or similar adhesive to the handle 

(item 28)

, and then slide the handle grip 

(item 44)

onto the 

handle.  The aerosol hairspray will allow for easier 
assembly and will adhere the grip to the handle.

NOTE:  When using a generator cover with this portability
kit, the handle must be moved to the downward position.

Your generator is supplied with a 25 foot 12 GA SJTW 

4-conductor 105ºC power cord set.  This cord is equipped with

an L14-20P twistlock Plug, on one end, which will plug directly
into the mating twistlock receptacle on the control panel of your
generator.  The opposite end comes equipped with a special 4
circuit connector comprised of four 5-20R receptacles.   These
may be used to power individual loads.  

Make sure the loads

do not exceed the 20 amp rating of the Power Cord Set.

Circuit breaker protection is provided for on the control panel of
your generator.

You will notice that the 4-circuit connector is color coded

with red and blue dots.  When several loads are powered at the
same time, it is best to keep equal loads supplied to each
separately colored half, if possible.  The red half and the blue
half of the connector are each capable of sustaining 20 amps of
current provided your generator is capable of supplying 4800
watts of power.  Check nameplate ratings for total wattage
capability of the generator. 

3

English

PORTABILITY KIT INSTALLATION

CORD SET

Отзывы: