OUTDOOR UNIT

Every unit includes 2 heavy-duty scroll compressors, 2 out-
door fan motors with inherent protection, subfusing and a
copper tube/aluminum fin coil.

All controls are located in the front of the unit in the control
box and are readily accessible for maintenance, adjustment
and service. All wiring (power and control) can be made
through the front of the unit.

ACCESSORIES (FACTORY & FIELD
INSTALLED)

Factory installed Non-Fused Disconnect for safety and
convenience.

Factory installed Technicoat Condenser Coils for corro-
sion protection.

Field Installed VFD (Variable Frequency Drive) for Low
Ambient operation down to 0ºF.

Field Installed Hot Gas Bypass for low load operation.

Field installed Pump-Out Kit for applications where liquid
slugging could be an issue.

FIGURE 2 : OUTDOOR PRODUCT NOMENCLATURE

PRODUCT NOMENCLATURE 

OUTDOOR CONDENSING UNITS AND HEAT PUMPS 

(UPG BRANDS) 

H F  - 10 C 00 A  T A  AA 1 A 

 

Model 

Model Number 
Description 

Options 

Product Category 

H = Air Conditioner Split System             E = Split System Heat Pump 

F

 

Product Identifier 

F = R-22 Standard Efficiency 2-Pipe 
L = R-22 Standard Efficiency 4-Pipe 

 

 

-10

 

Nominal Cooling 
Capacity 
MBH 

-07 = 7-1/2 Ton 
-10 = 10 Ton 
 

-15 = 15 Ton 
-20 = 20 Ton 

Heat Type 

C = Cooling Only 

 

00 

Nominal Heating 
Capacity 

00 = No Heat Installed 

 

Airflow Options 

A = Standard Motor 

 

 

 

Voltage 

T= 208/230-3-60    
W= 460-3-60     

 X= 575-3-60  
  

A

 

Installation Options 

A = None  
B = Disconnect  

  

AA 

Special Options 

AA = None 
AC = Technicoat 

 

 

Generation 

1 = First Generation 

 2 = Second Generation 

Style 

A = Style A 

 B = Style B 

 

 

 

 

Содержание HL180

Страница 1: ...ons Refrigerant 22 holding charge Five minute compressor anti short cycle timer Two independent control circuits Compressor operation to 40 F Field installed Low Ambient VFD Control to 0 F Five year l...

Страница 2: ...WEIGHTS 20 13 UNIT DIMENSIONS LL180 AND LL240 21 14 LL180 SUPPLY AIR PLENUM DIMENSIONS 22 15 RETURN AIR GRILLE FOR LL180 DIMENSIONS 22 LIST OF TABLES pg 1 Unit Application Data 7 2 ARI Ratings Coolin...

Страница 3: ...vertical applications the air velocity across the indoor coil keeps the condensate from dripping off the finned surface onto the filters NOTE On horizontal applications the unit must be installed wit...

Страница 4: ...d Installed Hot Gas Bypass for low load operation Field installed Pump Out Kit for applications where liquid slugging could be an issue FIGURE 2 OUTDOOR PRODUCT NOMENCLATURE PRODUCT NOMENCLATURE OUTDO...

Страница 5: ...e vertical indoor units above the floor Outdoor air may be introduced through these bases by cutting an access opening for the out door air duct connection These bases are finished to match the exteri...

Страница 6: ...ary Products Group FIGURE 4 VERTICAL ARRANGEMENTS LL180 AND LL240 FIGURE 5 HORIZONTAL ARRANGEMENTS LL180 AND LL240 CERTAIN BLOWER POSITIONS ARE NOT RECOMMENDED BECAUSE THE BLOWER MOTOR SHOULD NOT BE M...

Страница 7: ...rd 340 360 2 Ratings are in accordance with ARI standard 370 TABLE 3 ELECTRICAL DATA COMPRESSORS Model Number Compressors Power Supply System 1 System 2 RLA LRA RLA LRA HL180 208 230 3 60 25 6 190 0 2...

Страница 8: ...ctly connected to the condenser fans Motor rotation is counterclockwise when viewing the lead end which is opposite the shaft end 3 The amount of charge in the unit as shipped from the factory 4 Total...

Страница 9: ...op 1 1 Units must be installed outdoors Overhanging structures or shrubs should not obstruct condenser air discharge 120 Front access panels 36 Left Side 30 Right Side 30 Rear 24 Bottom2 2 Adequate sn...

Страница 10: ...AND ELECTRICAL CONNECTION LOCATIONS TABLE 11 PIPING AND ELECTRICAL CONNECTION SIZES CONNECTION ENTRY SIZE A SUCTION LINE SYS 1 1 3 8 ID B LIQUID LINE SYS 1 5 8 OD C SUCTION LINE SYS 2 1 3 8 ID D LIQUI...

Страница 11: ...145 7 123 4 101 0 Indicates Nominal Capacity Rating Point INPUT POWER INCLUDES THE CONDENSER AND COMPRESSOR MOTORS BUT NOT THE INDOOR BLOWER MOTOR 15 Ton Capacity Tables HL180 Matched with LL180 AIR...

Страница 12: ...0 2 127 8 105 5 83 1 Indicates Nominal Capacity Rating Point INPUT POWER INCLUDES THE CONDENSER AND COMPRESSOR MOTORS BUT NOT THE INDOOR BLOWER MOTOR 15 Ton Capacity Tables HL180 Matched with LL180 AI...

Страница 13: ...5 127 3 112 1 97 0 81 8 57 150 4 22 0 150 4 147 6 138 6 123 5 108 3 93 1 78 0 6000 72 174 2 23 3 129 7 112 2 94 7 77 2 59 7 N A N A 67 160 1 22 7 159 4 141 9 124 4 106 9 89 4 71 9 54 4 62 149 2 22 1 1...

Страница 14: ...89 8 162 4 134 9 Indicates Nominal Capacity Rating Point INPUT POWER INCLUDES THE CONDENSER AND COMPRESSOR MOTORS BUT NOT THE INDOOR BLOWER MOTOR 20 Ton Capacity Tables HL240 LL240 AIR ON EVAPORATOR O...

Страница 15: ...1 2 143 8 116 4 Indicates Nominal Capacity Rating Point INPUT POWER INCLUDES THE CONDENSER AND COMPRESSOR MOTORS BUT NOT THE INDOOR BLOWER MOTOR 20 Ton Capacity Tables HL240 LL240 AIR ON EVAPORATOR OU...

Страница 16: ...124 0 103 8 57 207 0 29 4 207 0 201 9 189 8 169 6 149 4 129 2 108 9 8000 72 237 2 30 8 172 9 149 6 126 3 102 9 79 6 N A N A 67 217 9 29 8 211 8 188 5 165 2 141 8 118 5 95 2 71 9 62 205 7 29 3 205 7 2...

Страница 17: ...68 7600 719 2 8 2 61 792 3 3 3 12 877 4 0 3 7 956 4 6 4 31 7800 730 3 0 2 78 807 3 5 3 31 888 4 1 3 88 960 4 8 4 49 Denotes use of 5 hp motor with high static pulley kit TABLE 19 LL240 20 TON AIRFLOW...

Страница 18: ...BLOWER PERFORMANCE 15 TON BLOWER PERFORMANCE 0 4 0 6 0 8 1 1 2 1 4 1 6 4200 4700 5200 5700 6200 6700 7200 7700 CFM ESP FIGURE 10 20 TON BLOWER PERFORMANCE 20 TON BLOWER PERFORMANCE 0 4 0 6 0 8 1 1 2...

Страница 19: ...3 2LR04603033 56 208 230 4601 1LD0436 640 810 5 2LR04605023 184 208 1LD0437 800 1000 2LR04605032 184 230 460 1LD0437 800 1000 LL240 5 2LR04605023 184 208 1LD0438 580 720 1LD0439 700 830 2LR04605032 18...

Страница 20: ...n Indoor Vertical 720 830 198 224 217 191 89 5 29 5 20 Ton Indoor Horizontal 990 1115 212 195 340 368 100 74 20 Ton Indoor Vertical 990 1115 281 254 276 305 100 36 5 FIGURE 11 LL HORIZONTAL APPLICATIO...

Страница 21: ...IMENSIONS LL180 AND LL240 TABLE 24 UNIT DIMENSIONS LL180 AND LL240 MODEL A B C D E F G H J K L M LL180 89 1 2 85 0 26 0 29 1 2 59 1 7 16 15 7 8 12 7 16 15 13 16 16 16 20 3 4 LL240 100 1 8 95 5 8 33 1...

Страница 22: ...036 21326 001 C 0202 22 Unitary Products Group FIGURE 14 LL180 SUPPLY AIR PLENUM DIMENSIONS1 1 Shipped knocked down for field assembly FIGURE 15 RETURN AIR GRILLE FOR LL180 DIMENSIONS...

Страница 23: ...036 21326 001 C 0202 Unitary Products Group 23...

Страница 24: ...o change without notice Printed in U S A 036 21326 001 C 0202 Copyright by Unitary Products Group 2001 All rights reserved Supersedes 036 21326 001 B 0202 Unitary 5005 Norman Products York OK Group Dr...

Отзывы: