12
Johnson Controls Unitary Products
632152-CTG-E-0812
* Notates “Hot Heat Pump” performance. These ratings are not AHRI Listed.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
— = Not Applicable.
MA Modular Air Handlers use Coil Only Ratings.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
— = Not Applicable.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
HEATING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
MODEL
COIL
1
MODEL
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @ 47
47 OD
17 OD
16 SEER HP WITH AIR HANDLERS
HC6B060F3(C)
AHE60D
–
1
1160
42.5
–
–
3.46
2
1835
58.0
39.0
9.00
3.80
2
1160*
57.0
38.5
8.60
3.28
AHV60D
–
1
1090
41.5
–
–
3.30
2
1635
59.5
38.0
8.95
3.60
2
1090*
57.5
37.0
8.70
3.46
MV20D
FC/MC62D
1
1075
41.5
–
–
3.42
2
1630
58.0
38.0
9.00
3.72
2
1075*
57.5
38.5
9.00
3.24
MV20D
FC64
1
1075
42.0
–
–
3.52
2
1630
58.0
38.0
9.00
3.82
2
1075*
58.0
38.5
9.00
3.32
MX20D
FC/MC62D
1
1390
43.0
–
–
3.62
2
1795
58.0
38.5
9.00
3.80
2
1390*
57.0
38.5
8.60
3.52
MX20D
FC64
1
1390
44.0
–
–
3.72
2
1795
58.0
39.0
9.00
3.94
2
1390*
57.0
39.0
8.60
3.62
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting pip-
ing and no supplemental electric heat operation.
HEATING CAPACITY - With Upflow, Downflow, & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT
MODEL
COIL
1
MODEL
HEATING
2
47
F
17
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
16 SEER HP COIL ONLY RATINGS
HC6B024F3(C)
FC/MC/PC32
23.6
3.56
1.94
15.6
2.38
1.92
7.80
FC/MC/PC35
23.6
3.56
1.94
15.6
2.38
1.92
7.80
FC/MC/PC37
23.6
3.70
1.87
15.5
2.50
1.82
7.80
FC/MC/PC43
23.6
3.70
1.87
15.5
2.50
1.82
7.80
HC6B030F3(C)
FC/MC/PC37
29.6
3.74
2.32
19.7
2.62
2.20
8.20
FC/MC/PC43
29.6
3.74
2.32
19.7
2.62
2.20
8.20
HC6B036F3(C)
FC/MC/PC48
35.6
3.70
2.82
24.0
2.62
2.68
7.80
FC/MC/PC60
35.6
3.86
2.70
23.8
2.72
2.56
7.80
UC48
36.0
3.86
2.82
24.0
2.68
2.62
7.80
UC60
36.0
3.84
2.84
23.4
2.60
2.64
7.80
HC6B042F4(C)
FC/MC/PC60
41.0
3.70
3.25
26.4
2.52
3.07
7.80
FC/MC62
41.0
3.88
3.10
26.4
2.62
2.95
7.80
UC60
41.5
3.80
3.20
26.0
2.60
2.93
7.80
HC6B048F3(C)
FC/MC62
47.0
3.64
3.78
34.2
2.60
3.85
7.80
FC64
47.0
3.76
3.66
34.8
2.66
3.83
7.80
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.