Coleman FC9T-UP Скачать руководство пользователя страница 4

246739-CTG-C-0407

4

Unitary Products Group

NOTES:

1. Airflow expressed in standard cubic feet per minute (CFM).
2. Return air is through side opposite motor (left side).
3. In order to stay within the velocity rating of the filters, airflows above 1800 CFM require either return from two sides or one side plus bottom.
4. Motor voltage at 115 V.
5. NR = Operation at this static pressure is not recommended.

BLOWER PERFORMANCE CFM

Airflow with Bottom or One Side Retrun - without Filters (CFM)

Models

Speed

Tap

External Static Pressure, Inches W.C.

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

FC9T040A12UP11

High

1395

1330

1265

1200

1120

1030

940

820

NR

NR

Med-High

1025

990

960

925

885

825

750

660

NR

NR

Med-Low

785

765

745

715

670

625

545

NR

NR

NR

Low

640

605

590

565

530

465

405

NR

NR

NR

FC9T060B12UP11
FC9T080B12UP11

High

1650

1605

1570

1525

1465

1410

1350

1275

1170

1060

Med-High

1165

1185

1175

1165

1150

1140

1100

1050

970

875

Med-Low

895

915

935

940

940

920

905

860

815

750

Low

710

725

725

725

720

700

685

660

625

560

FC9T080C16UP11
FC9T100C16UP11

High

1960

1955

1925

1890

1830

1765

1695

1615

1600

1485

Med-High

1565

1560

1560

1575

1545

1530

1475

1425

1365

1260

Med-Low

1230

1275

1285

1300

1310

1300

1280

1245

1190

1070

Low

930

945

965

975

975

975

975

950

910

850

FC9T100C20UP11

High

2300

2210

2120

2020

1930

1830

1715

1595

1480

1350

Med-High

1950

1900

1830

1755

1680

1595

1500

1390

1270

1155

Med-Low

1610

1545

1490

1440

1390

1315

1230

1155

1050

920

Low

1325

1270

1225

1175

1105

1045

990

905

890

790

FC9T120D20UP11

High

2560

2485

2410

2320

2220

2135

2035

1920

1785

1650

Med-High

2090

2050

1990

1970

1885

1820

1760

1675

1545

1405

Med-Low

1695

1675

1665

1615

1565

1510

1460

1385

1285

1140

Low

1175

1150

1135

1110

1085

1055

1005

980

970

845

Airflow with Two Side Returns or with Bottom and One Side Return - without Filters

Models

Speed

Tap

External Static Pressure, Inches W.C.

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

FC9T100C20UP11

High

2465

2380

2295

2195

2095

1995

1875

1760

1620

1470

Med-High

2085

2035

1960

1880

1800

1705

1605

1485

1360

1235

Med-Low

1725

1625

1595

1540

1485

1405

1315

1235

1125

995

Low

1420

1360

1310

1255

1180

1120

1070

970

950

845

FC9T120D20UP11

High

2615

2535

2450

2385

2285

2175

2075

1945

1825

1670

Med-High

2055

2045

2015

1985

1932

1855

1785

1730

1605

1470

Med-Low

1690

1650

1620

1600

1570

1525

1470

1395

1300

1200

Low

1345

1335

1335

1285

1250

1230

1180

1115

1010

850

Содержание FC9T-UP

Страница 1: ...operation includes Two stage gas valve Two stage inducer operation Provides increased comfort level very quiet unit opera tion Adjustable delay timer allows two stage operation with single stage therm...

Страница 2: ...P IMAGE SUPPLY END 1 1 2 GAS PIPE ENTRY 7 8 JUNCTION BOX HOLE T STAT WIRING 7 8 K O CONDENSATE DRAIN 7 8 K O A 40 FRONT CABINET AND DUCT DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A...

Страница 3: ...MANCE DATA Models Input High Low Output High Low Nominal Airflow Cabinet Width Total Unit AFUE Air Temp Rise MBH MBH CFM In Amps F FC9T040A12UP11 40 26 38 24 1200 14 1 2 9 94 0 35 65 FC9T060B12UP11 60...

Страница 4: ...d High 1565 1560 1560 1575 1545 1530 1475 1425 1365 1260 Med Low 1230 1275 1285 1300 1310 1300 1280 1245 1190 1070 Low 930 945 965 975 975 975 975 950 910 850 FC9T100C20UP11 High 2300 2210 2120 2020 1...

Страница 5: ...of high velocity filters 2 Air flows above 1800 CFM require either return from two sides or one side plus bottom RECOMMENDED FILTER SIZES Input Output BTU H CFM Cabinet Size Side Return Filter in Bot...

Страница 6: ...nction Light E W1 First Stage Heat G Fan G Fan Connection of the C Termainal 24 Volt Common is optional when used with batteries Thermostat Installer Setup Number 1 System Type must be set to 6 2 Heat...

Страница 7: ...SG Bonnet Sensor Bonnet Sensor Optional BS Bonnet Sensor W2 Second Stage Auxiliary Heat W2 Second Stage Auxiliary Heat AUX Auxiliary Heat E W1 First Stage Auxiliary Heat E W1 First Stage Auxiliary Hea...

Страница 8: ...w reduction value to airflow 0 50 to obtain actual airflow 0 58 ESP 2288 88 2197 ACCESSORIES CONCENTRIC VENT TERMINATION 1CT0302 2 1CT0303 3 For use through rooftop sidewall Allows combustion air to e...