350155-CTG-C-0808
4
Johnson Controls Unitary Products
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL
W
STAGE
RATED
CFM
NET MBH
SEER
EER
1 PH 18 SEER AC WITH MV
AC8B024F1
MV12B 17
FC/MC/PC35B
1 620
18.2
13.8
17.05
14.50
2 800
23.6
17.2
13.80
MV12B 17
FC/MC/PC35C
1 620
18.2
13.8
17.05
14.50
2 800
23.6
17.2
13.80
MV12B 17
FC/MC/PC43B
1 620
18.5
14.0
17.20
14.65
2 800
24.0
17.5
14.00
MV12B 17
FC/MC/PC43C
1 620
18.5
14.0
17.20
14.65
2 800
24.0
17.5
14.00
MV12D 24
FC/MC/PC48D
1 645
18.9
14.3
18.00
15.25
2 835
24.6
17.9
14.45
AC8B036F1
MV12B 17
FC/MC/PC43B
1 775
25.6
18.0
17.70
14.90
2 1200
36.0
25.2
13.55
MV16C 21
FC/MC/PC43C
1 775
25.7
18.1
18.00
15.00
2 1200
36.2
25.3
14.00
MV12D 24
FC/MC/PC48D
1 735
25.6
18.0
18.40
15.40
2 1135
36.0
25.2
13.95
MV16C 21
FC/MC/PC48C
1 775
25.9
18.2
18.40
15.40
2 1200
36.4
25.4
14.15
MV12D 24 FC/MC62D
1 735
25.7
18.1
18.50
15.40
2 1135
36.6
25.6
14.25
AC8B048F1
MV16C 21
FC/MC/PC48C
1 1000
34.0
25.1
17.30
14.20
2 1600
46.0
35.1
12.45
MV16C 21
FC/MC/PC48D
1 1000
34.0
25.1
17.30
14.20
2 1600
46.0
35.1
12.45
MV20D 24
FC/MC/PC48D
1 1020
34.0
25.1
17.00
14.00
2 1600
46.0
35.1
12.35
MV20D 24 FC/MC62D
1 1020
34.1
25.2
17.00
14.05
2 1600
46.5
35.5
12.50
AC8B060F1
MV20D 24
FC/MC/PC60D
1 1030
40.2
27.3
15.30
12.55
2 1800
55.5
40.5
11.55
MV20D 24 FC/MC62D
1 1030
42.1
28.6
16.00
13.20
2 1800
58.0
42.3
12.00
1 PH 18 SEER AC WITH AV/SV
AC8B024F1
AV36C
21
N / A
1 600
18.4
13.9
17.60
14.95
2 765
23.8
17.3
14.10
AC8B036F1
AV36C
21
N / A
1 830
25.7
18.1
18.00
15.25
2 1270
35.6
24.9
13.45
AC8B048F1
AV/SV48D
24
N / A
1 1135
33.1
24.4
16.60
13.60
2 1610
44.5
34.0
12.10
AV/SV60D
24
N / A
1 1085
33.0
24.4
16.50
13.60
2 1655
44.5
34.0
12.10
AC8B060F1
AV/SV60D
24
N / A
1 1145
41.5
28.2
15.70
13.00
2 1765
55.5
40.5
11.65
1 PH 18 SEER AC WITH F*F*
AC8B048F1
F4FV060
24
N / A
1 1200
33.6
24.8
16.85
13.75
2 1600
44.5
34.0
12.15
AC8B060F1
F4FV060
24
N / A
1 1200
41.8
28.4
15.55
12.80
2 1780
55.5
40.5
11.60
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
0
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1