524447-BTG-A-0809

                     

4

Johnson Controls Unitary Products

ACCESSORIES

Refer to Price Manual for specific model numbers.

Off Cycle Timer Delay 

- Provides a 5-minute off cycle to pre-

vent rapid recycling of the compressor.

Hard Start Kit 

- Required when using TXV indoor coil. Also,

provides increased starting torque for areas with low voltage.

Thermostats 

- Compatible thermostat controls are available

through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.

SOUND POWER RATINGS*

* Rated in accordance with ARI 270-95 Standards.

TYPICAL INSTALLATION

TYPICAL FIELD WIRING

Model

Source 1 Kit numbers

24

S1-2SA06721706

30

S1-2SA06705906

36

S1-2SA06708906

42

S1-2SA06708806

48

S1-2SA06708806

60

S1-2SA06707906

Unit Model

(dBA)

24

76

30

76

36

76

42

76

48

77

60

78

MINIMUM 18” SERVICE ACCESS

CLEARANCE ON ONE SIDE

60” OVERHEAD

CLEARANCE

6” CLEARANCE

COIL AREA

WEATHERPROOF

DISCONNECT

SWITCH

THERMOSTAT

TO FURNACE OR

AIR HANDLER

TERMINAL BLOCK

NEC CLASS 1 WIRING

NEC CLASS 2 WIRING

TO INDOOR COIL

SEAL OPENING(S) WITH

PERMAGUM OR EQUIVALENT

NOTE: ALL OUTDOOR WIRING MUST BE

POSSIBLE OUTDOOR THERMOSTAT KIT LOCATIONS

(UNIT MOUNTING NOT AVAILABLE ON ALL MODELS)

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-1-60

CONTACTOR

TERMINALS

COIL

GND.

LUG

C

Y

R

G

W

Y

R

G

W

POWER WIRING

CONTROL WIRING

FACTORY WIRING

24 VOLT CONTROL WIRING

MINIMUM 18 GA. WIRE

(NEC CLASS 2)

FURNACE OR AIR HANDLER TERMINAL BLOCK

ROOM THERMOSTAT

CONDENSING UNIT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

TERMINAL W IS ONLY

REQUIRED ON SYSTEMS

WITH HEAT.

*

*

Содержание CCGD24S41Q3

Страница 1: ... painted steel The pre treated galvanized steel provides a better paint to steel bond which resists corrosion and rust creep Special primer formulas and matted textured finish insure less fading when exposed to sunlight LOWER INSTALLED COST Installation time and costs are reduced by easy power and control wiring connections The unit contains enough refrigerant for matching indoor coils The small b...

Страница 2: ... Length 108 172 86 137 63 100 55 88 55 88 31 49 230V Max Length 1 8 1 4 1 4 1 4 1 4 1 4 Fan Motor Rated HP 0 80 1 40 1 50 1 50 1 50 1 50 Nominal RPM 1075 1100 850 850 850 850 Nominal CFM 1950 2050 3200 2950 2950 3600 Coil Face Area Sq Ft 9 6 9 6 13 1 14 2 14 2 18 7 Rows Deep 1 1 1 1 1 1 Fin Inches 23 23 23 23 23 23 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 3 8 3 8 Vapor Line Set OD Field ...

Страница 3: ...PC60 4473Q Footnotes 1 Match series number with table below for complete line set Part Number I e 2442 indicates 2442 8151 for a 15 ft installation requirement Pre charged Refrigerant Line Set Line Set Length ft Factory R 22 charge lbs oz Liquid Line Size Suction Line Size 4463Q1531 15 0 10 3 8 3 4 4463Q2031 20 0 13 4463Q2531 25 1 0 4463Q3031 30 1 3 4463Q4031 40 1 10 4463Q5031 50 2 0 4473Q1531 15 ...

Страница 4: ... 42 S1 2SA06708806 48 S1 2SA06708806 60 S1 2SA06707906 Unit Model dBA 24 76 30 76 36 76 42 76 48 77 60 78 MINIMUM 18 SERVICE ACCESS CLEARANCE ON ONE SIDE 60 OVERHEAD CLEARANCE 6 CLEARANCE COIL AREA WEATHERPROOF DISCONNECT SWITCH THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING TO INDOOR COIL SEAL OPENING S WITH PERMAGUM OR EQUIVALENT NOTE ALL OUTDOOR WIRING...

Страница 5: ... 7 18 7 16 5 17 8 13 9 KW 2 1 2 1 2 1 2 1 2 2 2 1 2 1 2 1 2 2 2 2 2 2 2 2 2 1 2 2 2 3 125 T C 13 5 14 9 13 8 16 8 20 1 15 5 16 9 15 6 18 3 21 6 17 5 18 9 17 4 19 8 23 1 S C 13 5 13 9 11 7 12 5 10 1 15 1 15 4 13 3 14 7 11 7 16 8 16 8 14 9 16 9 13 3 KW 2 2 2 2 2 2 2 3 2 4 2 3 2 3 2 2 2 3 2 4 2 3 2 3 2 3 2 3 2 4 NOTE ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH 1000 CFM COOLING PERFORMANCE DAT...

Страница 6: ... 5 23 3 19 8 20 3 15 4 KW 3 0 3 0 3 0 3 0 3 1 3 0 3 0 2 9 3 0 3 1 2 9 2 9 2 9 3 0 3 1 125 T C 21 3 23 2 21 1 23 7 27 6 20 9 22 3 20 2 23 2 27 3 20 5 21 3 19 3 22 7 27 0 S C 23 9 23 8 20 6 23 2 17 2 22 5 22 4 19 4 21 2 15 9 21 1 21 0 18 2 19 2 14 6 KW 3 2 3 2 3 2 3 2 3 4 3 2 3 2 3 1 3 2 3 3 3 1 3 1 3 1 3 2 3 3 NOTE ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH 1000 CFM COOLING PERFORMANCE DAT...

Страница 7: ... 2 37 7 32 8 33 3 23 8 KW 4 1 4 1 4 0 4 2 4 3 4 1 4 1 4 1 4 2 4 4 4 2 4 2 4 1 4 2 4 4 125 T C 33 1 32 4 28 1 33 5 35 1 34 5 33 8 29 4 34 4 35 5 35 9 35 3 30 6 35 2 36 0 S C 30 7 31 4 26 9 27 5 20 4 32 1 32 7 28 8 29 6 21 5 33 5 34 0 30 7 31 6 22 5 KW 4 4 4 4 4 3 4 4 4 6 4 4 4 4 4 3 4 5 4 7 4 5 4 5 4 4 4 5 4 7 NOTE ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH 1000 CFM COOLING PERFORMANCE DAT...

Страница 8: ...ange without notice Published in U S A 524447 BTG A 0809 Copyright 2009 by Johnson Controls Inc All rights reserved Supersedes 400040 BTG A 0408 Johnson Controls Unitary Products P O Box 19014 Wichita KS 67204 9014 ...