background image

Assembly

cont.

7

CAUTION

Contents of octenol cartridge are harmful if swallowed. Wash hands
before eating, drinking, chewing gum, using tobacco or using bathroom
facilities. Avoid contact with inside surface of foil package.

Step 13

■ 

Remove Mosquito Deleto

TM

octenol lure refill from foil 
package.

■ 

Install lure into unit with holes 

facing center of trap.

■ 

Photos below show detail of adhesive trap sliding over tray rails (typical

both edges).

• Do not attempt to operate until you have read & understand all General 

Safety Information in this manual, all assembly is complete and leak 
checks have been performed.

• After lighting the unit for the first time it is normal to see some smoke 

coming from the burner area. This smoke is the result of the burning of 
residual oils from the manufacturing process. The smoke will disappear 
within 10-15 minutes. 

DANGER

• EXPLOSION - FIRE HAZARD

• Never store propane near high heat, open flames, pilot lights, direct 

sunlight, other ignition sources or where temperatures exceed 120 
degrees F (49°C).

• Propane is heavier than air and can accumulate in low places. If you 

smell gas, leave the area immediately.

• Never install or remove propane tank while unit is operating, near 

flame, pilot lights, other ignition sources or while unit is hot to touch.

• This unit is hot during use and can ignite flammables. Keep gasoline 

and other flammable liquids and vapors well away from unit.

• The propane tank must always be stored outdoors in a well-ventilated 

space. Never store propane tank in an enclosed area (house, garage, 
etc.). If unit is to be stored indoors, disconnect the propane tank for out-
door storage.

■ 

Unit may be secured by driving stakes through

holes in feet.

Step 15

■ 

Slowly open Tank Valve.

■ 

Allow system to fill for approximately 60 seconds.

■ 

Press and hold Red Ignitor Button.

■ 

Ignition should occur within 30 seconds and will be indicated by

thermometer movement.

Step 14

■ 

Remove the waxed paper from 
the adhesive trap.

Helpful Tip:

On hot days, the waxed paper will
remove easily if the adhesive trays
are cool. Store traps indoors.

■ 

Install one adhesive trap into back 

of unit and one adhesive trap into 
front of unit.

Note: Adhesive surface must face
toward outside.

Operation

• CARBON MONOXIDE HAZARD

• For outdoor use only. Never use inside house, or other unventilated 

or enclosed areas. This unit consumes air (oxygen). Do not use in 
unventilated or enclosed areas to avoid endangering your life. 

DANGER

To Turn On

CAUTION

Unit cannot be match lit. Do not attempt.

Содержание 8fa3

Страница 1: ...436 6 055 766 D466578 D468389 U S and other Patents Pending 2002 The Coleman Company Inc www coleman com IMPORTANT Read this manual carefully before assembling using or servicing this unit Keep this manual for future reference If you have questions about assembly operation servicing or repair please call Coleman at 1 800 835 3278 or TDD 316 832 8707 For Outdoor use only ...

Страница 2: ... information such as an instruction manual or labels contact The Coleman Co Inc DANGER General Safety Information Improper installation adjustment alteration service or maintenance can cause injury or prop erty damage Read the instructions thoroughly before installing or servicing this equipment WARNING WARNING For Outdoor Use Only This product is fueled by propane gas Propane gas is invisible odo...

Страница 3: ...nt during operation of this product get fresh air immediately For outdoor use only Never use inside house or other unventilated or enclosed areas This unit consumes air oxygen Do not use in unventi lated or enclosed areas to avoid endangering your life DANGER Front Bar Base Collar Consumables Bag Feet Axle Tank Retainer Hardware Tank Cover Wheels Head Assembly Mosquito DeletoTM Inhibitor Axle Bush...

Страница 4: ...sting of contents for the model you purchased Step 2 With a lightweight hammer tap Axle Bushings into Base Make sure Bushings are fully seated TOOLS REQUIRED OTHER ITEMS not provided Standard Phillips head screwdriver 7 16 end wrench Lightweight hammer Mosquito DeletoTM Inhibitor Refill Linalool Stakes Adhesive Trap Mosquito DeletoTM Octenol Lure Refill Axle Bushing Base Axle Bushings will receive...

Страница 5: ...t Head Assembly on legs with Handle positioned as shown Step 7 cont Step 6 Turn Head Assembly over while holding Lid closed Attach Collar to Head Assembly Align ribs on Collar with Ignitor Install screws and tighten Ignitor Ribs on Collar Install Tank Retainer at Leg position opposite the Handle Grip Tank Retainer Handle Grip Actual size Actual size Actual size Step 7 Install Carriage Bolts Washer...

Страница 6: ...ylinder Valve OFF Disconnect reconnect and perform another leak check If you continue to see bubbles after several attempts cylinder valve or hose is defective and should be replaced Defective cylinders should be returned to cylinder s place of purchase If NO bubbles appear at connec tion the connection is secure Turn Cylinder Valve OFF Cylinder Valve NOTE Whenever gas connection is loosened or re...

Страница 7: ...stall or remove propane tank while unit is operating near flame pilot lights other ignition sources or while unit is hot to touch This unit is hot during use and can ignite flammables Keep gasoline and other flammable liquids and vapors well away from unit The propane tank must always be stored outdoors in a well ventilated space Never store propane tank in an enclosed area house garage etc If uni...

Страница 8: ...o operate around the clock in your yard The Trap continuously attracts traps and kills mos quitoes all day and all night 6 Together the Mosquito DeletoTM Inhibitor and Trap are a strong defense against mosquitoes 7 Place the inhibitor unit per instructions in the inhibitor package To Turn On cont To Turn Off Verify ignition by observing gauge Turn cylinder valve OFF Unit can be moved from location...

Страница 9: ...ved before doing maintenance WARNING 1 Use the Mosquito DeletoTM Inhibitor to push mosquitoes away from you use the Mosquito DeletoTM Trap to attract and kill mosquitoes 2 The Mosquito DeletoTM Inhibitor is designed for occasional use Turn it on when going outdoors to gently disperse the scent that blocks the mosquitoes sensors Turning the unit off will close the vents and preserve the unit for fu...

Страница 10: ...pply hose is bent or kinked Straighten hose Adhesive Panels Panels exposed to direct sunlight Move out of direct sunlight If desired replace dripping 10 Mosquito DeletoTM Refills Mosquito DeletoTM Inhibitor Model 2950 603 Mosquito DeletoTM System Refill Model 2950 700 Mosquito DeletoTM Octenol Lure Refill Model 2960 601 Mosquito DeletoTM Trap Cartridge Refill Model 2960 602 Mosquito DeletoTM Inhib...

Страница 11: ...ssembly no wires 5 2910A0981 Thermometer 6 2910 3581 Transition Piece w 3 bolts 7 2910 0801 1 Individual Leg 8 2910 3601 Axle 2 Wheels 9 2910 3591 Base Assembly D ring 2 Feet Support Bar Hardware 10 2910 0931 Tank Holder Assembly 11 2950 3701 Tank Cover 12 2910 8001 Head Assembly 13 2910 0311 Ignitor Button 14 2910 0371 Gas Tip 1 2 9 6 8 4 7 11 3 5 10 12 14 13 ...

Страница 12: ...structions or failure to follow maintenance instructions commercial in profit or non profit instructional or rental applications disassembly repair or alteration by anyone other than Coleman or an authorized service center Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes Coleman shall not be liable for any incidental or consequential damages caused by the...

Отзывы: