ADJUSTABLE FIRESTOP THIMBLE (FST-A): 

The Adjustable Firestop Thimble Assembly  (FST-A) is used 
to provide the necessary air space and clearance between the 
chimney pipe and the insulation in the attic space of a 
manufactured home. 
To install the thimble assembly, determine the distance 
between the ceiling joist and the roof framing.  Attach the 
adjustable thimble to the firestop spacer so that the assembly 
will cover the distance.  The adjustable thimble should be even 
with or above the roofline (see thimble extensions on page 10 
if a longer thimble is needed).  Sheet metal screws or staples 
may be used to attach the thimble to the firestop spacer.   
An opening large enough to allow the insertion of the firestop 
thimble assembly will be required in the ceiling.  Attach the 
firestop/thimble assembly to the ceiling/ceiling joists using 
screws or staples as shown in figure 8.  A minimum of 8 
screws or staples should be used. 
 

The firestop thimble assembly should also be used where there 
is a cathedral ceiling, insulation barrier and roof, all in one 
assembly in a manufactured home (see figures 9 & 10).  The 
FST-A Thimble can be used in any one of three common 
ceiling pitches; flat, 12”/96”, and 30”/144”. 
An opening big enough to allow the insertion of the firestop 
thimble assembly will be required.  This opening depends on 
the pitch of your ceiling.  If your ceiling is a flat or 12”/96” 
pitch, you must use the adapter plate provided to seal 
unwanted openings since the opening in the firestop is an 
ellipse.  For 30”/144” pitch, discard the adapter. 

If the adapter is needed, secure it onto the firestop using holes 
provided (see figure 10).  The row of holes on the sides of the 
thimble is provided to allow for pitch variances.  Position the 
firestop assembly and thimble to desired angle and secure with 
screws provided.  Insert the thimble and firestop into the 
prepared opening and secure to the ceiling by nailing through 
the firestop flanges.  The thimble should be even with or 
above the roofline. Thimble extensions are available (as an 
option) when required.  See “accessories” on page 10.   

NOTE: If there is a second story in the home, firestop 
spacer FS-8DM will be required.  See “Firestop Spacer” 
on page 9. 
 
PENETRATING THE ROOF: 

To maintain a 2-inch clearance to the pipe on a roof with a 
pitch, a rectangular opening must be cut. 

STEP 1:

 Determine the center point through which the pipe 

will penetrate the roof. 

STEP 2:

 Determine the center point of the roof. Pitch is the 

distance the floor drops over a given span, usually 12 inches. 
A 6/12 pitch means that the roof drops 6 inches for each 12 
inches measured horizontally down the roof.  

STEP 3:

 Use the roof-opening chart (figure 11) below to 

determine the correct opening length and flashing required. 

STEP 4:

 Remove the shingles around the opening measured 

and cut out this section. 

STEP 5:

 Add the next sections of the pipe until the end 

penetrates the roofline.  Check to see that the proper 
clearances are maintained. Extend chimney by adding sections 
of double wall pipe until pipe is a minimum of 30 inches  
above the highest point of the roof cutout. Termination and 
chimney must extend a minimum of 36 inches above the 
highest point where it passes through roof. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

IMPORTANT:

 If an exposed portion of chimney is greater 

than four feet above the roofline, use support wires to keep the 
chimney secured.  The support wires may be attached to the 
outer pipe of the chimney with screws provided the screws do 
not penetrate the inner flue pipe. 

Figure 10 

Figure 8  

    Figure 9 

 

 

 

Figure 11 

PITCH

SLOPE

OPENING "A" MAX

USE FLASHING

(degrees)

(inches)

MODEL NO.

FLAT

0

17

V6F-8DM

0 - 6/12

26.6

19 - 1/8

V6F-8DM

6/12 - 12/12

45.0

24 - 1/4

V12F-8DM

Содержание 36 LM

Страница 1: ...UCTIONS WARNING ALWAYS LEAVE GLASS DOORS FULLY OPENED OR FULLY CLOSED WHEN OPERATING THIS FIREPLACE This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A vent free log can only be installed in an aftermarket completion of sale ...

Страница 2: ... 3 6 OUTSIDE AIR KIT INSTALLATION PG 4 7 FAN KIT ASSEMBLY PG 4 8 CHIMNEY PIPE INSTALLATION PG 4 5 6 9 TERMINATIONS PG 6 10 FINISHING YOUR FIREPLACE PG 7 11 MANTELS PG 7 12 GLASS DOORS PG 7 13 GAS LINE INSTALLATIONS PG 8 14 FIRESTOP SPACER PG 9 15 DAMPER OPERATION PG 9 16 TECHNICAL SERVICE PG 9 17 REPLACEMENT AND TECHNICAL PARTS PG 10 ...

Страница 3: ... the cutting of joists or roof rafters will make installation easier 4 An outside air kit is included with this fireplace For more details refer to section on outside air kit installation on page 4 WARNING DO NOT INSTALL IN A BEDROOM MINIMUM CLEARANCES TO COMBUSTIBLES Back and sides of fireplace 3 4 Min Note the clearance is not required at the nailing flanges Ceiling to Top of Opening 66 1 4 Min ...

Страница 4: ... prevent corrosion STEP 6 Using screws or nails secure the fireplace to the framing through flanges located on the sides of the fireplace see figure 4 HEARTH EXTENSION A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace Use DESA hearth extension see acc...

Страница 5: ...t chimney systems for manufactured houses require a standard straight installation as described in this section Important If the height of the chimney assembly exceeds requirements for transportation of the home the chimney installation may be completed after the home is sited Note the termination must always be installed after the home is sited ASSEMBLING AND INSTALLING THE DOUBLE WALL CHIMNEY SY...

Страница 6: ...he firestop assembly and thimble to desired angle and secure with screws provided Insert the thimble and firestop into the prepared opening and secure to the ceiling by nailing through the firestop flanges The thimble should be even with or above the roofline Thimble extensions are available as an option when required See accessories on page 10 NOTE If there is a second story in the home firestop ...

Страница 7: ...p terminations In any case refer to the installation instructions supplied with the termination The terminations approved for this fireplace are the RT 8DM and RTL 8DM Figure 14 shows an RTL 8DM round top termination IMPORTANT Terminations are required but can be installed once the manufactured house is sited CAUTION DO NOT SEAL OPENINGS ON THE ROOFTOP FLASHING FOLLOW THE INSTALLATION INSTRUCTIONS...

Страница 8: ...ce of the fireplace The clearances from the side of the fireplace to any combustible material and wall should fall within the limits shown in figure 17 Example 1 figure 18 The face of a mantel bookshelf etc is made of combustible materials and protrudes 3 3 8 from the wall the fireplace is installed in This combustible material must be a minimum of 8 from the side of the fireplace opening Example ...

Страница 9: ... released Remove fragmented portions of refractory see figure 20 STEP 2 Remove gas line cover plate on rear of fireplace and pull out insulation from gas line conduit sleeve Save insulation for reuse STEP 3 Run a inch black iron gas line into the fireplace through the rear at 11 inches from the floor and through gas line conduit sleeve if using a raised platform add height Provide sufficient gas l...

Страница 10: ...in the keyway slot will free the damper blade to automatically open To close reach in and push the handle back into the keyhole slot then pull down and forward to lock it in place see figure 23 FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER TO YOUR HOMEOWNERS GUIDE OR CONTACT YOUR AUTHORIZED DEALER TECHNICAL SERVICE You may have further questions about installa...

Страница 11: ...Double Wall Pipe 1 3 0 18 8DM 18 Double Wall Pipe 0 0 2 FST A Adjustable Firestop Thimble 1 1 1 6F 8 Roof Flashing 1 1 1 VSC1 8DM Storm Collar 1 1 1 RTL 8DM Round Cap Termination 1 1 1 VENT KITS USE FOR MOST COMMON MANUFACTURED MOBILE HOME INSTALLATIONS SEE BELOW PART NUMBERS VENT KIT ACCESSORY PARTS REPLACEMENT PARTS ...

Страница 12: ...Double Wall Pipe 1 3 0 18 8DM 18 Double Wall Pipe 0 0 2 FST A Adjustable Firestop Thimble 1 1 1 6F 8 Roof Flashing 1 1 1 VSC1 8DM Storm Collar 1 1 1 RTL 8DM Round Cap Termination 1 1 1 VENT KITS USE FOR MOST COMMON MANUFACTURED MOBILE HOME INSTALLATIONS SEE BELOW PART NUMBERS VENT KIT ACCESSORY PARTS REPLACEMENT PARTS ...

Страница 13: ...P N 035 16687 000 ...

Отзывы: