Troubleshooting Guide
Symptom
Possible Cause
Solution
Hot water
warning
Water tank/carrier is running out of water
Fill water tank/carrier with water.
Environment temperature is high
Turn control knob to a cooler setting.
Temperature sensor defective
Contact Coleman Service Center and return the product to Coleman when necessary.
Tilt
warning
Heater is tilted more than 30 degrees.
Gas & pump will be shut off immediately.
Sensor defective
Contact Coleman if under warranty.
Flames out
warning
Flames blown out by strong wind / pilot light is
out
Do not use in strong wind condition. Turn off the heater completely and restart the ignition
sequence.
Flame detection module defective
Contact Coleman if under warranty.
Low battery
warning
Battery voltage lower than 9.8V.
Recharge the battery.
Defective battery
Contact Coleman if under warranty.
Low water flow
warning
Pump is not in correct position
Rotate pump so “THIS SIDE UP” is facing upward.
Water tank/carrier out of water
Fill water tank/carrier with water.
Pump inlet screen clogged
Clean the screen, seen instructions given in maintenance section.
Hose twisted / kinked
Straighten hose.
Battery lead disconnected
Remove battery cover & reinstall lead.
Pump power cord disconnected
Plug cord into power socket on heater.
Low battery
Recharge the battery.
Flow rate sensor defective
Contact Coleman if under warranty.
Burner will not light
Propane cylinder empty
Replace cylinder.
Propane cylinder frosted
Replace cylinder and reuse after thawing.
Fuse defective
Refer to maintenance section and replace the fuse.
Electronic circuit defective
Contact Coleman if under warranty.
Water leakage
Connectors cross-threaded;
Sleeved-connectors were not locked into place
Reconnect the connectors.
Read instructions for connecting sleeved connectors and reconnect the connectors.
Defective seal or break
Replace sealing components (O-rings) or send to Coleman when necessary
Hose turns white or
discolors inside
Calcium buildup
Clean heater (refer to section “cleaning instructions” on page 7)
Battery won’t hold a Charge
Defective Battery
Contact Coleman if under warranty.
Main power switch is neglected
See Helpful Hints section on how to use the main power switch
No display
Battery lead disconnected
Remove battery cover & reinstall lead
Fuse defective
Refer to maintenance section and replace the fuse.
Electronic circuit defective
Contact Coleman if under warranty.
Low battery
Recharge the battery.
Main power switch at “OFF” position (for model
2302-A only)
Turn on the main power switch
Technical Characteristics
Pressure: 2.8 kPa
Injector size: 0.026 in (0.66 mm)
Total gas consumption: 21.0 MJ/h
Gas type: Propane LPG
Replacement Parts
Parts List
1. 2000027853 Shower
2. 2000027851
Li-Ion Battery
3. 2000027849
Pump Assembly
4. 2000027850
Adapter – 120V
5. 2000027848
Adapter – 12V
6. 2000027847
Water Carrier
7. 2000027845
Shower Arm
8. 2000027844 Fuse
9. 2000027842
Shower Assembly Carry bag
10. 2000027937
Shower Hose
- Contact Coleman -
www.coleman.com
|
1-800-835-3278
|
TDD 316-832-8707
Содержание 2302-A
Страница 40: ...39 NOTE REMARQUE NOTA ...