background image

2. Introduction

The instructions in this manual are task-oriented for easy reference. You can go directly
to a particular  section and quickly find the answers. Appendix A (See page 12) lists
tubing loading capacity depending on the maximum rpm of your Masterflex®  L/S®
pump drive used with this system.

Pump Heads

These multichannel pumps, designed to provide up to eight simultaneously driven
pump channels, incorporate the following features:

• Simultaneous dispensing through up to eight separate channels with one set-up
and pump cycle.

• Six-roller design that provides reduced pulsation

Application Data

The pump head is designed for multichannel use. Tubing found in Table 2 
(See page 9) may be used to deliver from .0026 to 200 mL/min.

General Description

Each pump head is constructed with rugged anodized aluminum frames, stainless
steel rotor assemblies, and either one or two precision machined aluminum occlu-
sion beds. Occlusion beds are designed to compress the Masterflex microbore tubing
for optimum performance—no occlusion adjustment is required. Each occlusion bed
will accommodate up to 4 channels of microbore tubing. Pump heads can be stacked
(up to eight, 4-channel or four, 8-channel pump heads) to allow up to 32 channels of
simultaneous pumping. Each pump head contains 6 rollers with shielded stainless
steel bearings, and can quickly mount to most existing Masterflex® L/S® tubing
pump drives.

2.2

2.1

Model  

Type

07534-04

6 roller, 4 channel

07534-08

6 roller, 8 channel

3

1. Safety Precautions

WARNING:

Tubing breakage may result in fluid being sprayed from pump.

Use appropriate measures to protect operator and equipment.

Turn off drive before removing or installing tubing. Safety guard is provided to 
minimize risk of fingers getting caught between roller mechanism and the base of
the module. However, be safe—keep your fingers away from these areas.

CAUTION: 

Use only tubing combinations defined by Tables 1 and 2 (See

page 9). Use of other tubing could cause malfunction or damage to the
pump.

WARNING: PRODUCT USE LIMITATION

These products are not designed for, or intended for use in, patient-

connected applications, including, but not limited to, medical and dental use and,
accordingly, have not been submitted for FDA approval.

Model   07534-04

Model   07534-08

Figure 1, Pump Heads

2

Содержание Barnant Masterflex 07534-04

Страница 1: ...only 11 847 549 1700 Fax outside U S www masterflex com e mail techinfo coleparmer com ISO 9001 SUPPLIER CERTIFIED Manufactured by Barnant Company 28W092 Commercial Ave Barrington Illinois U S A 60010 2392 1 800 637 3739 U S and Canada only 11 847 381 7050 Outside U S 847 381 7050 Local 11 847 381 7053 Fax outside U S 847 381 7053 Local fax www barnant com e mail barnant barnant com ISO 9001 REGIS...

Страница 2: ...al Co Viton Reg TM DuPont Dow Elastomers LLC Trademarks bearing the symbol in this publication are registered in the U S and in other countries Cole Parmer Instrument Company 625 East Bunker Court Vernon Hills Illinois 60061 1844 1 800 MASTERFLEX 627 8373 U S and Canada only 11 847 549 7600 Outside U S 847 549 7600 Local FAX 847 247 2929 U S and Canada only 11 847 549 1700 Fax outside U S www mast...

Страница 3: ...s required Each occlusion bed will accommodate up to 4 channels of microbore tubing Pump heads can be stacked up to eight 4 channel or four 8 channel pump heads to allow up to 32 channels of simultaneous pumping Each pump head contains 6 rollers with shielded stainless steel bearings and can quickly mount to most existing Masterflex L S tubing pump drives 2 2 2 1 Model Type 07534 04 6 roller 4 cha...

Страница 4: ...mp heads together with the four screws provided using the holes in the four corners of the pumps Figure 3 Stacking Pump Heads Adhesive backed support feet supplied may be used to stabilize pump stack Remove adhesive backing and attach feet to underside of front plate of front pump 3 1 5 3 Installation Tool required long hex key provided Mount the pump head to a Masterflex L S pump drive as follows...

Страница 5: ...d is provided to minimize risk of fingers getting caught between roller mechanism and the base of the module However be safe keep your fingers away from these areas CAUTION Use only tubing combinations defined by Tables 1 and 2 See page 9 Use of other combinations could cause malfunction or damage to the pump With the drive stopped follow this procedure to install tubing 1 Release latch and open o...

Страница 6: ... 2 Compatible Tubing Use only specially designed microbore tubing sets 5 1 Tubing Material Microbore Tubing Set mm ID 0 19 0 25 0 89 1 42 2 06 2 79 Soft Silicone platinum ü Stiff PVC ü ü ü Viton ü Santoprene ü ü Drive Units Microbore Tubing Set mm ID Rpm 0 19 0 25 89 1 42 2 06 2 79 Microboreow Rates 100 mL min 26 53 5 4 12 23 35 600 mL min 30 67 125 200 Flow Rates 9 Figure 8 Secure tubing stop col...

Страница 7: ...n For your protection pack the product carefully and insure it against possible damage or loss Any damages resulting from improper packaging are your responsibility Select Pump Speed Select fixed speed drive or adjust speed of variable speed drive to provide desired nominal flow rate within the rpm speed range shown for the pump model selected 6 Maintenance No maintenance is required Wipe the pump...

Страница 8: ...ct the Manufacturer or authorized seller for details 13 12 Tubing ID Platinum cured Santoprene PVC Viton mm silicone 0 19 06416 10 0 25 06431 12 06416 12 0 89 06421 26 06431 26 06416 26 06428 26 1 42 06421 34 06431 34 06416 34 06428 34 2 06 06421 42 06431 42 06416 42 06428 42 2 79 06421 48 06431 48 06416 48 06428 48 Quantity pk 6 12 12 12 Maximum No of Channels Tubing Material 100 600 rpm drive rp...

Отзывы: