background image

5

Model with rechargeable batteries 

• 

Always disconnect the power cord from the microscope before you replace the rechargeable batteries

• 

The rechargeable batteries must not be thrown away as regular trash but should be taken to special waste 
collection sites, according your local or national regulations

• 

Risk of explosion: when removing the rechargeable batteries, do not throw the batteries into fire or any other 
heat source

• 

Do not replace the rechargeable batteries with non-rechargeable batteries

• 

Avoid extreme environmental conditions and temperatures which could affect the rechargeable batteries and 
lead to fire, explosion or leakage of hazardous substances

• 

If the rechargeable batteries have leaked, avoid contact of the chemicals with skin, eyes and mucous 
membranes

• 

When in contact with the chemicals, flush the affected areas immediately with plenty of fresh water and seek 
medical attention

Environment, storage and use

• 

Maximum altitude: 2000 m

• 

Pollution degree: 2

• 

This product is a precision instrument and it should be used in a proper environment for optimal use

• 

Install your product indoors on a stable, vibration free and level surface in order to prevent this instrument to 
fall thereby harming the operator

• 

Do not place the product in direct sunlight

• 

The ambient temperature should be between 5 to +40°C and humidity should be within 20 to 80% RH

• 

Although the system is anti-mold treated, installing this product in a hot, humid location may still result in the 
formation of mold or condensation on lenses, impairing performance or causing malfunctions

• 

Never turn the right and left focus knobs in opposite directions at the same time or turn the coarse focus knob 
past its farthest point as this will damage this product

• 

Never use undue force when turning the knobs

• 

Make sure that the microscope system can dissipate its heat (fire hazard)

• 

Keep the microscope away from walls and obstructions for at least approximately 15 cm

• 

Never turn the microscope on when the dust cover is in place or when items are placed on the microscope

• 

Keep flammable fluids, fabric, etc. well out of the way

Disconnect power

Always disconnect your microscope from power before doing any maintenance, cleaning, assembling or replacing 
LEDs to prevent electric shocks

Prevent contact with water and other fluids

Never allow water or other fluids to come in contact with your microscope, this can cause short circuiting your device, 
causing malfunction and damage to your system

Moving and assembling

• 

This microscope is a relatively heavy system, consider this when moving and installing the system

• 

Always lift the microscope by holding the main body and base of the microscope

• 

Never lift or move the microscope by its focusing knobs, stage or head

• 

When needed, move the microscope with two persons instead of one

Содержание 78903-90

Страница 1: ...Installation and Operating Instructions MSU 100 Series Compound Microscope Model 78903 90...

Страница 2: ...omponents of the microscope____________________________________________________ 7 Preparing the microscope for use __________________________________________________ 8 Assembling Steps _______________...

Страница 3: ...a cover glass never comes in direct contact with the microscope parts In that case prevention of contamination lies in the handling of the slides as long as the slides are decontaminated before use a...

Страница 4: ...based disinfection products for laboratories Before returning a microscope for repair or maintenance through a Cole Parmer dealer an RMA return authorization form together with a decontamination state...

Страница 5: ...be between 5 to 40 C and humidity should be within 20 to 80 RH Although the system is anti mold treated installing this product in a hot humid location may still result in the formation of mold or con...

Страница 6: ...and the slide The Numeric Aperture N A of the objective is an indication for the resolving power of the objective The total magnification can be calculated by multiplying the magnification of the eye...

Страница 7: ...for 3 or 4 objectives B Safety device J Objectives C Tension adjustment K Object stages mechanical stage or clips D On Off switch not visible L Height adjustment lever condenser E Light intensity con...

Страница 8: ...r head please pull out the power cord immediately and dry the microscope Assembling Steps Mounting the objectives 1 Rotate the coarse focusing knob to lower the stage to its lowest position 2 Install...

Страница 9: ...is lost or damaged choose one with the same specifications Replacement of the Power Cord If the power cord requires replacement ensure that it is suitably rated If in doubt consult your local dealer o...

Страница 10: ...ng with a S100x objective you need to lock the slide protection screw D The slide protection screw protects the slide by limiting the travel range of the mechanical stage This way the objectives will...

Страница 11: ...h the object stage an Abbe condenser N A 1 25 is mounted The condenser can be adjusted in height by moving the lever beneath the mechanical stage N By adjusting the condenser you can focus the light o...

Страница 12: ...er Clean the front lens of the S100x objective 11 Always clean the front lens of the S100x objective with a piece of lens paper that is moistened with a drop of isopropanol 12 Clean the slide after us...

Страница 13: ...ust can be removed with high pressured air There will never be dust in the objectives if the objectives are not removed from the revolving nosepiece Caution Cleaning cloths containing plastic fibers c...

Страница 14: ...as bulbs batteries fuses cords optical components or any add on accessories such as mechanical specimen holders that are not built into the microscope stage as an integral part of the original manufa...

Страница 15: ...______________________________________________________ ___________________________________________________________________________________________________ _____________________________________________...

Страница 16: ...2022 Cole Parmer Instrument Company LLC Toll free 1 800 323 4340 Phone 1 847 549 7600 Fax 1 847 247 2929 coleparmer com 1065Y62_M_CP_MSU 100_Series_Compound Microscope_Manual...

Отзывы: