USING PORTABLE AIR (85 - 500 HP / 64 - 373 KW)
Portable air compressors are mainly used for shop tools, not dry ice blasting units; therefore, they
are not able to cool or remove air moisture.
An after cooler and moisture trap/filter MUST be used. An after cooler with a 15 °F (-9 °C) approach
is required to reduce the discharge air temperature 180 °F (82 °C) to within 15 °F (-9 °C) of ambient
air temperature.
If an air cooler is not used:
Incoming air moisture will rapidly cool and freeze at the Aero V feeder.
Ice will accumulate in the feeder, distorting the air flow and seal.
Ice will break off inside the hose and lodge in the nozzle, causing a jam.
Ice may exit the nozzle and damage the target surface.
If blasting continuously, use an air dryer to further reduce the air moisture (dew point). Desiccant
dryers produce a dew point of -40 °F (-40 °C), resulting in a dew point low enough for continuous
blasting.
To verify the compressor is of adequate size for the Aero V, the air compressor needs to produce an
air volume 10% greater than the Aero V's maximum permissible air volume. To determine
adequate air volume, watch the pressure gauge while blasting.
If the gauge drops slowly, the compressor is insufficient.
If the gauge drops quickly, there is a restriction or the pipe is too small.
If the gauge stays steady, then the compressor and piping are adequate.
To maintain adequate pressure, the hose size from the compressor to the Aero V needs to be 1" (25
mm) in diameter.