Page 21 

 

 
 
 

5.  Fasten impeller with clamp adapter set on motor shaft 

 

(Do not tight yet the clamp adapter) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

6.  Fasten inlet section on the casing 

 

 
 
 
 
 
 
 
 
 
 

7.  Adjust impeller, tighten clamp adapter set 

 

Mount hub cap. Mount V-belt protection 

 
 
 
 

 
 
Dismantling in the same way but in reverse order 

 
 
 

 
 

Содержание CMVeco 125

Страница 1: ...Subject to alteration Copyright by COLASIT AG Spiez Page 1 OPERATION MANUAL CMVeco 125 400 Plastic industrial fan Agent Order No Fan type Year of manufacture For use in Ex zones Not for use in Ex zon...

Страница 2: ...deserves your full attention please read it carefully The contents of this operating manual are subject to change without notice in order to take technical progress into account The manual contains ic...

Страница 3: ...RCENCY STOP 11 6 Operation 11 6 1 Safety instructions 11 6 2 Putting out of operation 11 7 Maintenance repair cleaning 12 7 1 Preparation 12 7 2 Performance 13 8 Spare parts 14 9 Operating instruction...

Страница 4: ...ator has notified us of the gas mix and the maximum operating temperature the suitability and any applicable restrictions will be confirmed in the data sheet of COLASIT AG In the absence of a written...

Страница 5: ...damage nor that the fan will cause any damage 1 5 Personnel qualifications The fan may only be put into operation handled operated maintained and cleaned by trained personnel who are authorised and c...

Страница 6: ...peration It may only be put into operation again when the safety devices are fully functional again Overpressure If the fan is operated in overpressure conditions with normal seals there is a danger o...

Страница 7: ...ment connected to it has not been installed and checked out and until the operating manual has been read completely before commissioning We stipulate that the fan may only be put into operation when t...

Страница 8: ...ding terminal of the motor and fan must be connected to a potential equalization system Motors with protection type e are standard for using in the explosion proof design of our fans The standard vers...

Страница 9: ...form The signed form must be kept by the safety officer or operating company COLASIT also offers a comprehensive installation service for fans 3 Shipping unpacking inspection storage The fan is comple...

Страница 10: ...ter or condensate into the fan To ensure this please use the COLASIT condensate drain nozzles Due to the possibility of noise nuisance we recommend that the fan should not be installed in the immediat...

Страница 11: ...is installed To interrupt the power supply an EMERGENCY STOP switch must be provided It is advisable to mount this switch in the vicinity of the emergency exit Please request confirmation from an in...

Страница 12: ...ushed with fresh air and be condensate free Fan must be at room temperature Personal protective equipment must be available and it must be worn Use of protective gloves because of sharp edges ear prot...

Страница 13: ...learance between the impeller and casing minimum 1 of intake diameter maximum 20mm Measure the vibrations at bearings KA or motor DA Alarm according to ISO 14694 3 7 kW categorie BV 2 14 0 mm s r m s...

Страница 14: ...ent Solvents can corrode the material These may only be used with the written consent of COLASIT To carry out cleaning work we recommend the production of a process instruction 8 Spare parts Please id...

Страница 15: ...If faults occur we recommend you identify and clear them using the following table If the fault cannot be cleared please contact our customer service department Fault Possible causes Remedy Fan not r...

Страница 16: ...ories If not already a part of our scope of supply these original parts are available ex stock when ordered Frequency converters Elastic sleeves Vibration dampers Condensats drains Motor cover for out...

Страница 17: ...n CH 3700 Spiez Phone 41 0 33 655 61 61 Fax 41 0 33 654 81 61 TD 000 674 E Edition 4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 17 16 Dimensional drawings 16 1 Dimensions of the CMV...

Страница 18: ...construction CH 3700 Spiez Phone 41 0 33 655 61 61 Fax 41 0 33 654 81 61 TD 000 674 E Edition 4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 18 16 2 Dimensions of the CMVeco 125 400...

Страница 19: ...Assembly instructions 17 1 Assembly instructions CMVeco 125 400 with direct drive 1 Attach motor to the support 2 Attach casing to the support 3 Fasten impeller with the clamp adapter set on motor sh...

Страница 20: ...Edition 4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 20 17 2 Assembly instructions for CMVeco 125 400 with V belt drive 1 Install flanged bearings and support plates 2 Bolt motor br...

Страница 21: ...Subject to alteration Copyright by COLASIT AG Spiez Page 21 5 Fasten impeller with clamp adapter set on motor shaft Do not tight yet the clamp adapter 6 Fasten inlet section on the casing 7 Adjust im...

Страница 22: ...1 0 33 654 81 61 TD 000 674 E Edition 4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 22 18 Spare parts lists 18 1 Spare parts list for CMVeco 125 400 with direct drive 1 Support 2 Cas...

Страница 23: ...4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 23 18 2 Spare parts list for CMVeco 125 400 with V belt drive 1 Support 8 Feet motor 2 Casing 9 Motor plate with bracket 3 Inlet section...

Страница 24: ...ction CH 3700 Spiez Phone 41 0 33 655 61 61 Fax 41 0 33 654 81 61 TD 000 674 E Edition 4 2016 Subject to alteration Copyright by COLASIT AG Spiez Page 24 Part 3 Certification 19 Certifications 19 1 EU...

Страница 25: ...purpose in explosive atmospheres in compliance with Annex II of the Directive The following harmonised standards were applied EN 1127 1 Explosive atmospheres Explosion protection Part 1 2012 EN 13463...

Страница 26: ...ne 1 2 an explosion proof motor with temperature class T4 must be fitted If an explosion proof motor with temperature class T3 is used temperature class T3 shall apply to the entire fan Ambient temper...

Страница 27: ...2016 Subject to alteration Copyright by COLASIT AG Spiez Page 27 19 3 Further certificates This operating manual has the following certificates enclosed Datasheet of the fan ATEX Certification Inspect...

Страница 28: ...are connected close to the fan With free intake blow off fans a protective grating with a mesh width of 10mm is fitted The clearance between the impeller and the casing is min 5mm and max 20mm All rot...